Catalog excerpts
MAGNETOSTRICTIVE SENSOR Absolute measuring length up to 3 m linear position transducer Absolute contactless linear position measurement Designed for integration into hydraulic cylinders High resolution and linearity High shock and vibration resistance Unlimited mechanical life Plug-in flange Rod, nipple and flange in AISI 316 Simple integration in cylinders with M12 plug-system Customizable cursor Position, speed and acceleration measurement 3m Wide temp. range High accuracy Firmware Upgradable The company reserves the right to make any kind of design or functional modification at any moment without prior notice. TSM SENSORS S.R.L. Registered office:Via Roma 110, 24021 Albino (BG) - ITALY Operational Headquarter : Via Alcide De Gasperi , 6/8 25030 Zocco d’Erbusco (BS) - ITALY P.IVA: 04334290162 - C.F: 03757080985 TEL. +39 030 7001376 - info@tsmsensors.com - www.tsmsensors.com
Open the catalog to page 1MAGNETOSTRICTIVE SENSOR Absolute measuring length up to 3 m linear position transducer PRODUCT DESCRIPTION MAG300 is a magnetostrictive position transducer with flange connection, designed for mobile machines which can be completely installed inside oil-pressure cylinders. Its unique design, plus a wide range of cursor configurations, ensures easy installation and full compatibility with cylinder manufacturer specifications. High performance in terms of transduction of measurement defined as linearity, hysteresis and repeatability. The company reserves the right to make any kind of design...
Open the catalog to page 2MAGNETOSTRICTIVE SENSOR Absolute measuring length up to 3 m linear position transducer PRODUCT CODE Power supply range Measurement range = CANopen with diagnostics = Plug system M12, 5-pin with wires 60mm = Plug system M12, 5-pin with wires 150mm = Plug system M12, 5-pin with wires 300mm = PUR Cable, black not shielded, Ø5mm 5x0.25 mm 1mt Cursor type = Magnetic cursor 18 x 8 mm - AW2011A anodized = Magnetic cursor 18 x 10 mm - AW2011A anodized (1) Not all combinations can be ordered. Please contact TSM for confirmation before placing an order. (2) Redundanted primary measures, acquired by a...
Open the catalog to page 3MAGNETOSTRICTIVE SENSOR Absolute measuring length up to 3 m linear position transducer OPERATING PRINCIPLE Measuring range Magnetostrictive resolution Operating pressure Protection class IP67 (IP69K with M12 plug system) Temperature range Temperature coefficient Head and rod: stainless steel AISI316 Shock resistance Vibration resistance The operating principle is based on the magnetostrictive effect. The application of periodic short current pulses in the magnetosctrictive wire generates an induced magnetic field. The interaction of the magnetic cursor, connected to the moving object in the...
Open the catalog to page 4MAGNETOSTRICTIVE SENSOR Absolute measuring length up to 3 m linear position transducer ELECTRICAL CONNECTIONS PLUG SYSTEM M12 X 5 PINS PIN * GND and CAN_GND terminals are internally connected to each other and identical in their function FRONT VIEW CABLES FRONT VIEW * GND and CAN_GND terminals are internally connected to each other and identical in their function The company reserves the right to make any kind of design or functional modification at any moment without prior notice. TSM SENSORS S.R.L. Registered office:Via Roma 110, 24021 Albino (BG) - ITALY Operational Headquarter : Via...
Open the catalog to page 5MAGNETOSTRICTIVE SENSOR Absolute measuring length up to 3 m linear position transducer CURSOR TYPES Magnetic cursor 18 x 10 mm - AW2011 anodized Magnetic cursor 18 x 8 mm - AW2011 anodized The company reserves the right to make any kind of design or functional modification at any moment without prior notice. TSM SENSORS S.R.L. Registered office:Via Roma 110, 24021 Albino (BG) - ITALY Operational Headquarter : Via Alcide De Gasperi , 6/8 25030 Zocco d’Erbusco (BS) - ITALY P.IVA: 04334290162 - C.F: 03757080985 TEL. +39 030 7001376 - info@tsmsensors.com - www.tsmsensors.com
Open the catalog to page 6MAGNETOSTRICTIVE SENSOR Absolute measuring length up to 3 m linear position transducer The company reserves the right to make any kind of design or functional modification at any moment without prior notice. TSM SENSORS S.R.L. Registered office:Via Roma 110, 24021 Albino (BG) - ITALY Operational Headquarter : Via Alcide De Gasperi , 6/8 25030 Zocco d’Erbusco (BS) - ITALY P.IVA: 04334290162 - C.F: 03757080985 TEL. +39 030 7001376 - info@tsmsensors.com - www.tsmsensors.com
Open the catalog to page 7MAGNETOSTRICTIVE SENSOR Absolute measuring length up to 3 m linear position transducer Head fixing Magnet seat The company reserves the right to make any kind of design or functional modification at any moment without prior notice. TSM SENSORS S.R.L. Registered office:Via Roma 110, 24021 Albino (BG) - ITALY Operational Headquarter : Via Alcide De Gasperi , 6/8 25030 Zocco d’Erbusco (BS) - ITALY P.IVA: 04334290162 - C.F: 03757080985 TEL. +39 030 7001376 - info@tsmsensors.com - www.tsmsensors.com
Open the catalog to page 8MAGNETOSTRICTIVE SENSOR Absolute measuring length up to 3 m linear position transducer OPERATING MANUAL Intended use MAG300 sensors are designed to be used on hydraulic devices installed on mobile machines or vehicles with battery power (12VDC or 24 VDC). MAG300 are designed and built in compliance with current electrical engineering standards and are made to the state of the art. They meet the EMC requirements for interference emission and immunity for mobile machines and vehicles. However, their use may endanger the user or third parties or cause damage to the sensor and other equipment....
Open the catalog to page 9MAGNETOSTRICTIVE SENSOR Absolute measuring length up to 3 m linear position transducer - Do not open or disassemble the sensor. - Connect the sensor carefully; check the polarity of the power connections; do not invert the power cables with the signal cables; do not power the sensor with a voltage outside the allowed limits - Do not remove the antistatic cover until the sensor needs to be connected to the system. If the sensor is disconnected, put the cover back until reinstallation. - Do not use the sensor outside the operating temperature range. - Always check the correct operating of the...
Open the catalog to page 10All TSM SENSORS SRL catalogs and technical brochures
-
CET5 CANopen
6 Pages
-
TLP300 CANopen
7 Pages
-
TLP300 Analog
7 Pages
-
CAN.I/O.100
6 Pages
-
TLA200 Analog INCLINOMETER
7 Pages
-
TLK100 TILT SWITCH
7 Pages
-
TLP200 Analog
6 Pages
-
CET12 CANopen
6 Pages
-
CET12 Analog
5 Pages
-
CET20 CANopen
6 Pages
-
RTE200 CANopen
8 Pages
-
RTP100H CANopen
7 Pages
-
RTA100 CANopen
7 Pages
-
RTP100 CANopen
8 Pages
-
RTB100 CANopen
8 Pages
-
MAG200 CANopen
6 Pages
-
MAG200 Analog
6 Pages
-
MAG100 CANopen
6 Pages
-
MAG100 Analog
6 Pages
-
CET.5000 Analog
5 Pages
-
CET.5000 Relay
5 Pages
-
TLP210 CANopen
5 Pages
Archived catalogs
-
CAN.I/O.100
6 Pages
-
TLP100
6 Pages
-
RTE100
6 Pages
-
MAG310
5 Pages
-
CET.5000
5 Pages
-
TLK100
6 Pages
-
TSM Applications
8 Pages
-
Sensors RTP100
6 Pages
-
RTE200
7 Pages
-
RTE100
6 Pages
-
MAG300 ANALOG
5 Pages
-
CET10000 ANALOG
4 Pages
-
CET5000 ANALOG
4 Pages
-
TSM brochure
12 Pages
-
TLK100
6 Pages
-
TLP300 ANALOG
6 Pages
-
TLP300
5 Pages
-
CET5000 Switches
4 Pages
-
TLA200
5 Pages
-
CET10000 CANopen
5 Pages
-
CET5000 CANopen
5 Pages
-
MAG300
5 Pages
-
MAG200
5 Pages
-
CET5000 - ABZ Incremental
4 Pages
-
CET10000 – Analog
4 Pages
-
CET10000 - CanOpen
5 Pages
-
CET5000 - Switch
4 Pages
-
CET5000 - Relay
4 Pages
-
TLX100
4 Pages
-
TLP200
4 Pages
-
CET5000 – Analog
4 Pages
-
TLP 100 - INCLINATION SENSOR
6 Pages
-
CET5000 - CANOpen
5 Pages
-
RTA100 - Analog
5 Pages