Absolute measuring length up to 2.5 m linear position transducer Top Sensors Manufacture CHARACTERISTICS ADVANTAGES Measuring range up to 2.5 m Designed for integration into hydraulic cylinders High shock and vibration resistance Plug-in flange Operating pressure up to 350 bar Customizable cursor Absolute contactless linear position measurement High resolution and linearity Unlimited mechanical life Rod, nipple and flange in AISI 316 Simple integration in cylinders with M12 plug-system Position, speed and acceleration measurement High protection level Wide temp. range RoHS compliant The company reserves the right to make any kind of design or functional modification at any moment without prior notice. TSM SENSORS S.R.L. Registered office:Via Roma 110, 24021 Albino (BG) - ITALY Operational Headquarter : Via Alcide De Gasperi , 6/8 25030 Zocco d'Erbusco (BS) - ITALY P.IVA: 04334290162 - C.F: 03757080985 TEL. +39 030 7001376 - [email protected] - www.tsmsensors.com
Open the catalog to page 1MAGNETOSTRICTIVE SENSOR Absolute measuring length up to 2.5 m linear position transducer PRODUCT DESCRIPTION The temperature range from -40 to +85°C, the operating pressures up to 350 bar and the high resistance to vibration and shock make the sensor very robust, a fundamental feature in heavy-duty applications. High performance in terms of transduction of measurement defined as linearity, hysteresis and repeatability. The company reserves the right to make any kind of design or functional modification at any moment without prior notice. TSM SENSORS S.R.L. Registered office:Via Roma 110, 24021...
Open the catalog to page 2Absolute measuring length up to 2.5 m linear position transducer Top Sensors Manufacture PRODUCT CODE ■dr .dr Power supply range [b Active stroke range Dead zone 20 •< = 20 mm only for backwards compatibility 26A 4 = Plug system M12, 4-pin with wires 60mm 26B -< = Plug system M12, 4-pin with wires 150mm 26C •< = Plug system M12, 4-pin with wires 300mm 9 < = Cable 5Mt 4x0,25mm2 PUR/PVC 0 4 = Magnetic cursor 18 x 8 mm - AW2011A anodized 1 4 = Magnetic cursor 18 x 10 mm - AW2011A anodized (1) Not all combinations can be ordered. Please contact TSM for confirmation before placing an order. (2) Standard...
Open the catalog to page 3MAG300 AnalogMAGNETOSTRICTIVE SENSOR ^ Absolute measuring length up to 2.5 m linear position transducer Top Sensors Manufacture TECHNICAL SPECIFICATION - OPERATING PRINCIPLE Measuring range ELECTRICAL CHARACTERISTICS The operating principle is based on the magne-tostrictive effect. The application of periodic short current pulses in the magnetosctrictive wire generates an induced magnetic field. The interaction of the magnetic cursor, connected to the moving object in the application, with this field generates a momentary torsional strain on the magnetostrictive wire which propagates along it...
Open the catalog to page 4Absolute measuring length up to 2.5 m linear position transducer The company reserves the right to make any kind of design or functional modification at any moment without prior notice. TSM SENSORS S.R.L. Registered office:Via Roma 110, 24021 Albino (BG) - ITALY Operational Headquarter : Via Alcide De Gasperi , 6/8 25030 Zocco d'Erbusco (BS) - ITALY P.IVA: 04334290162 - C.F: 03757080985 TEL. +39 030 7001376 - [email protected] - www.tsmsensors.com
Open the catalog to page 5MAG300 AnalogMAGNETOSTRICTIVE SENSOR ^ Absolute measuring length up to 2.5 m linear position transducer Top Sensors Manufacture CURSOR TYPES 1] Magnetic cursor 18 x 10 mm - AW2011 anodized 2] Magnetic cursor 18 x 8 mm - AW2011 anodized Section A-A The company reserves the right to make any kind of design or functional modification at any moment without prior notice. TSM SENSORS S.R.L. Registered office:Via Roma 110, 24021 Albino (BG) - ITALY Operational Headquarter : Via Alcide De Gasperi , 6/8 25030 Zocco d'Erbusco (BS) - ITALY P.IVA: 04334290162 - C.F: 03757080985 TEL. +39 030 7001376 - [email protected]...
Open the catalog to page 6MAG300 Analog ijq||MAGNETOSTRICTIVE SENSOR Absolute measuring length up to 2.5 m linear position transducer Top Sensors Manufacture The company reserves the right to make any kind of design or functional modification at any moment without prior notice. TSM SENSORS S.R.L. Registered office:Via Roma 110, 24021 Albino (BG) - ITALY Operational Headquarter : Via Alcide De Gasperi , 6/8 25030 Zocco d'Erbusco (BS) - ITALY P.IVA: 04334290162 - C.F: 03757080985 TEL. +39 030 7001376 - [email protected] - www.tsmsensors.com
Open the catalog to page 7MAGNETOSTRICTIVE SENSOR Absolute measuring length up to 2.5 m linear position transducer Head fixing Magnet seat The company reserves the right to make any kind of design or functional modification at any moment without prior notice. TSM SENSORS S.R.L. Registered office:Via Roma 110, 24021 Albino (BG) - ITALY Operational Headquarter : Via Alcide De Gasperi , 6/8 25030 Zocco d’Erbusco (BS) - ITALY P.IVA: 04334290162 - C.F: 03757080985 TEL. +39 030 7001376 - [email protected] - www.tsmsensors.com
Open the catalog to page 8MAGNETOSTRICTIVE SENSOR Absolute measuring length up to 2.5 m linear position transducer OPERATING MANUAL Intended use MAG300 sensors are designed to be used on hydraulic devices installed on mobile machines or vehicles with battery power (12VDC or 24 VDC). MAG300 are designed and built in compliance with current electrical engineering standards and are made to the state of the art. They meet the EMC requirements for interference emission and immunity for mobile machines and vehicles. However, their use may endanger the user or third parties or cause damage to the sensor and other equipment....
Open the catalog to page 9MAG300 AnalogMAGNETOSTRICTIVE SENSOR ^Absolute measuring length up to 2.5 m linear position transducer Top Sensors Manufacture -Never use a steel hammer! Do not subject the sensor and the tools to hard strokes during installation! If necessary, use only a rubber mallet to hammer the sensor in position carefully - Do not open or disassemble the sensor. - Connect the sensor carefully; check the polarity of the power connections; do not invert the power cables with the signal cables; do not power the sensor with a voltage outside the allowed limits - Do not remove the antistatic cover until the...
Open the catalog to page 106 Pages
5 Pages
6 Pages
6 Pages
7 Pages
7 Pages
8 Pages
5 Pages
7 Pages
6 Pages
6 Pages
7 Pages
8 Pages
8 Pages
7 Pages
6 Pages
6 Pages
10 Pages
6 Pages
6 Pages
6 Pages
5 Pages
5 Pages
5 Pages
6 Pages
7 Pages
6 Pages
5 Pages
6 Pages
6 Pages
4 Pages
4 Pages
5 Pages
5 Pages
6 Pages
5 Pages
5 Pages
5 Pages
4 Pages
8 Pages
4 Pages
5 Pages
4 Pages
4 Pages
12 Pages
5 Pages
4 Pages
4 Pages
4 Pages
4 Pages
5 Pages
6 Pages
5 Pages
5 Pages