The DP-Calc 5815 and 5825 micromanometers are designed for HVAC pressure measurements. These instruments are compatible with Pitot probes for duct velocity measurement. The DP-Calc 5815 is a handheld device for differential and static pressure measurements, while the DP-Calc 5825 offers additional features such as flow calculation and data logging.
Applications
  • HVAC commissioning and troubleshooting
  • Testing and balancing
  • Pitot tube duct traverses
  • Static pressure measurements
  • Pressure drop across filters, coils, fans, and diffusers
  • Environmental air flow testing
Features and Benefits
  • Measures differential and static pressure from -15 to +15 in. H2O (-3735 to +3735 Pa)
  • Calculates and displays velocity with a Pitot tube
Additional Features of Model 5825
  • Flow calculation
  • Variable time constant
  • Statistics
  • Data logging with time and date stamp
  • Stores over 12,700 samples and 100 test IDs
  • Includes LogDat2™ downloading software
  • Programmable K factors
Specifications
  • Static/Differential Pressure Range: -15 to +15 in. H2O (-28.0 to +28.0 mm Hg, -3735 to +3735 Pa)
  • Accuracy: ±1% of reading ±0.005 in. H2O (±0.01 mm Hg, ±1 Pa)
  • Resolution: 0.001 in. H2O (0.1 Pa, 0.01 mm Hg)
  • Velocity Range (Pitot Tube): 250 to 15,500 ft/min (1.27 to 78.7 m/s)
  • Accuracy: ±1.5% at 2,000 ft/min (10.16 m/s)
  • Duct Size (5825): 1 to 500 inches in increments of 0.1 in. (2.5 to 1270 cm in increments of 0.1 cm)
  • Volumetric Flow Rate (5825): Dependent on velocity, pressure, duct size, and K factor
  • Operating Temperature Range: 40 to 113°F (5 to 45°C)
  • Storage Temperature Range: -4 to 140°F (-20 to 60°C)
  • Data Storage (5825): Over 12,700 samples and 100 test IDs
  • Logging Interval (5825): 1 second to 1 hour
  • Time Constant (5825): User selectable
  • Dimensions: 3.3 in. x 7.0 in. x 1.8 in. (8.4 cm x 17.8 cm x 4.4 cm)
  • Weight with Batteries: 0.6 lbs. (0.27 kg)
  • Power Requirements: Four AA-size batteries (5815); Four AA-size batteries or optional AC adapter (5825)
Additional Information
Specifications are subject to change without notice. DP-Calc is a trademark, and TSI and the TSI logo are registered trademarks of TSI Incorporated. For more information, visit the TSI website or contact their offices worldwide.
See more

Catalog excerpts

DP-Calc 5825-1

DP-Calc™ Micromanometers Models 5815 and 5825 The DP-Calc 5815 and 5825 micromanometers allow you to easily make HVAC pressure measurements. These robust instruments can be used with Pitot probes to measure duct velocity. The DP-Calc 5815 is a simple to operate, hand held digital micromanometer for fast, accurate differential and static pressure measurements. The high performance DP-Calc 5825 can calculate flow and has data logging capabilities. Applications Features and Benefits + HVAC commissioning and troubleshooting + easure differential and static pressure from -15 to +15 in. H2O M + Testing and balancing + Pitot tube duct traverses (-3735 to +3735 Pa) + Calculate and display velocity when using a Pitot tube + Static pressure measurements + Pressure drop across filters, coils, fans, and diffusers Added Features Model 5825 + Environmental air flow testing + Calculates flow + Variable time constant + Statistics + Data logging with time and date stamp + Stores 12,700+ samples and 100 test IDs + Includes LogDat2™ downloading software + Programmable K factors UNDERSTANDING, ACCELERATED

 Open the catalog to page 1
DP-Calc 5825-2

DP-CALC™ MICROMANOMETERS Static/Differential Pressure Velocity (Pitot Tube) Volumetric Flow Rate (5825) Range Actual range is a function of velocity, pressure, duct size, and K factor Instrument Temperature Range Data Storage Capabilities (5825) Range 12,700+ samples and 100 test IDs User selectable External Meter Dimensions Meter Weight with Batteries Power Requirements Four AA-size batteries (5815) Four AA-size batteries or optional AC adapter (5825) Overpressure range = 190 in. H20 (7 psi, 360 mmHg, 48 kPa). Pressure velocity measurements are not recommended below 1,000 ft/min (5 m/s). 3Accuracy...

 Open the catalog to page 2

All TSI catalogs and technical brochures

  1. 5000 SERIES

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.