| Type | Torque (Nm) | Duty Cycle S4 (%) | Operating Time (sec.) 50 Hz / 60 Hz | Max. Bore Size Key / Square (ø / •) | Rated Current (A) 1 phase 220 50 Hz / 60 Hz | Motor Insulation Class | ISO 5211 Mounting Flange | Weight (Kg) | No. of Hand Wheel Turns |
|---|---|---|---|---|---|---|---|---|---|
| ITQ 010 | 100 | 40 | 21 / 18 | 22 / 20 | 0.52 / 0.58 | F | F07 | 7 | 10 |
| ITQ 016 | 160 | 30 | 26 / 22 | 25 / 23 | 0.85 / 0.90 | F | F07/F10 | 15 | 12 |
| ITQ 024 | 240 | 30 | 26 / 22 | 25 / 23 | 0.87 / 0.90 | F | F07/F10 | 15 | 12 |
| ITQ 035 | 350 | 30 | 31 / 26 | 40 / 34 | 0.92 / 0.95 | F | F10/F12 | 20 | 14 |
| ITQ 050 | 500 | 30 | 31 / 26 | 40 / 34 | 1.50 / 1.60 | F | F10/F12 | 20 | 14 |
| ITQ 080 | 800 | 30 | 39 / 32 | 48 / 40 | 2.05 / 2.20 | F | F12/F14 | 25 | 17 |
| ITQ 110 | 1100 | 30 | 39 / 32 | 48 / 40 | 2.15 / 2.30 | F | F12/F14 | 25 | 17 |
| ITQ 200 | 2000 | 30 | 59 / 50 | 75 / 64 | 2.95 / 3.15 | F | F16 | 42 | 13 |
| ITQ 300 | 3000 | 30 | 59 / 50 | 75 / 64 | 3.75 / 3.85 | F | F16 | 42 | 13 |
Electrical Actuator type ITQ 010-300 STANDARD SPECIFICATION Self locking - Provided by double worm gearing to keep position of valve unchanged against reverse torque from valve. Motor - Specially designed induction motor to generate high starting torque and high efficiency equipped with thermal protector to prevent damage from over heating. Torque switches - Protects actuator from damage caused by overload from the driven valve over the whole travel. 1 for each open/close. Manual override - Auto / Manual switchable lever and hand wheel engagement for emergency manual operation. Drive force automatically resorted by motor start, unless lever padlocked to prevent this occuring. External mechanical stopper - Prevents over run of travel angle when limit switch fails. Removable drive bushing and ISO5211 mounting base - (F07~F16) for easy mounting on valve. TECHNICAL DATA Wiring diagram included with delivery Krossgatan 22 B SE-162 50 Vallingby Sweden