Catalog excerpts
Model 3410 Electronic LCD Hour Meter Description Maintenance Meters are offered with an optional maximum of 3 “Redi-Alerts” to alert users when service is due. Models are available with optional front panel field or fac- tory programmable alerts. Not only does the display flash to get attention, but it displays a choice of 7 different .08”[2mm] maintenance icons. Users can program or specify the service interval and flash duration for each Redi-Alert. Flash duration is the amount of time in hours that the specific icon flashes before and after the service interval. If a front panel manual reset of the Redi-Alert is required the front panel models with switches must be specified. Totally sealed from moisture and dirt AC or DC voltage input in the same unit Tachometer/Hour Meter versions Compact depth Fits in existing panel openings Always on display 15+ Year Battery Life A choice of 6 housings A choice of reset modes Front panel programmable Preset Timer with output Can be programmed with starting time Programmable output thresholds Preset Hour Meter/time up or down Up to 3 Redi-Alerts/7 icons Specifications Display: LCD with large 0.28” [7mm] high figures black on light background Blinking decimal point Remote, manual and non-reset (remote reset not available on surface mount housing) Maximum Withstanding voltage: 30VDC, reference to Common Maximum Load current: 0.1Amp Hour Meter Resolution: 0.01 or 0.1 Hour, displayed; 1 second, internal Environmental: Temperature: (Storage and Operating) -40 to +185˚F [-40 to +85˚C] Humidity: 95% RH per SAE J1378 Vibration: 20g @ 10 to 80 Hz per SAE J1378 Shock: 44 to 55g’s per SAE J1378 Dielectric: 1000VAC 50/60 Hz for 1 minute Compliance: Compliant to the European WEEE and RoHS Directives ± 0.1% @ room temperature ± 0.2% over the specified temperature range Totally sealed EMC Compliance: Records & Displays: EN61326:1997 with A1:1998 and A2:2001 for industrial environments Protection Against: Alternator load dump: 150V EMI (Electromagnetic Interface): +400V @ 500Hz inductive switching and reverse polarity Enclosure: Power: Self powered - battery life 15+ years Standard 0.250” [6.4mm] spades 1 meter wire (inductive) Totally sealed from moisture and dirt, NEMA 4/4X, 12, & IP66 compliant from the front when properly mounted using the optional gasket. (Not applicable to Snap-In Model) UL and cUL Recognized (file # ELIY2.E36690), CE, SAE, NEMA 4/4X compliant Output: Format: Open-Drain MOSFET with Source
Open the catalog to page 1Model 3410 Electronic LCD Hour Meter Functions Optilnal Front panel switches can be used for reset, display selection and programming. The two front Panel switches are used as follows: Front Panel Switch Functions: SEL: During programming this switch is used to select options. The SEL switch is used during programming to move horizontally in the programming flow chart. This is the reset switch during normal operation. During programming the RST switch is used to enter an option. The RST switch is used during programming to move vertically in the programming flow chart. Available Icons SERVICE...
Open the catalog to page 2Model 3410 Electronic LCD Hour Meter Panel Cutout: 1.46” [37mm] x 0.95” [24.1mm] Minimum Panel Thickness: 0.04” [1.0mm] Maximum Panel Thickness: 0.125” [3.18mm] Notes 1. When interfacing the Model 34 with a Solid State Relay or AC Sensor, the leakage current needs to be considered. C 2. Exceeding the Absolute Voltage Range and the Absolute Maximum Limits may result in damage to the unit. Applications Medical Devices Control Panels Production Equipment Garden Tractor
Open the catalog to page 3Model 3410 Electronic LCD Hour Meter Part Number AC/DC HOUR METER 2 HOLE 1/4" SPADE TERMINALS NON-RESET AC/DC HOUR METER 2 HOLE 1/4" SPADE TERMINALS REMOTE-RESET 5003-010 AC/DC HOUR METER 2 HOLE 1/4" SPADE TERMINALS PROGRAMMING 5003-010 AC/DC HOUR METER THREE HOLE CASE 1/4" SPADE TERMINALS NONRESET AC/DC HOUR METER THREE HOLE CASE 1/4" SPADE TERMINALS REMOTE-RESET AC/DC HOUR METER FLUSH RECT CASE 1/4" SPADE TERMINALS NONRESET AC/DC HOUR METER FLUSH RECT CASE 1/4" SPADE TERMINALS REMOTE-RESET AC/DC HOUR METER ROUND SAE CASE 1/4" SPADE TERMINALS NONRESET AC/DC HOUR METER ROUND SAE CASE 1/4"...
Open the catalog to page 4All TRUMETER catalogs and technical brochures
-
99 Series
2 Pages
-
2300, 2401 & 2701 Series
2 Pages
-
TR3 Heavy Duty Tru-Trac™
3 Pages
-
15T / 15H Encoder
3 Pages
-
Model 750
1 Pages
-
46 Series
2 Pages
-
29 Series
2 Pages
-
22 Series
2 Pages
-
20 Series
1 Pages
-
3602 Series
2 Pages
-
9100 Series
2 Pages
-
94 Series
2 Pages
-
18 Series
2 Pages
-
Model 6300
3 Pages
-
Model 3400
2 Pages
-
7111 | 7111HV
2 Pages
-
7110-DIE Counter
1 Pages
-
7000/7000AS
2 Pages
-
732 Series
3 Pages
-
722 Series
3 Pages
-
711 Series
6 Pages
-
PRODUCT Catalogue
44 Pages
-
CT Meter
2 Pages
-
APM Process Meter
3 Pages
-
Shunt Meter
2 Pages
-
924K
4 Pages
-
B Series
2 Pages
-
BVA
2 Pages
-
CTF16/17
2 Pages
-
CTR52U
2 Pages
-
E660, E760
2 Pages
-
H37 Series
1 Pages
-
H57
1 Pages
-
HB26 Series
2 Pages
-
HC77
1 Pages
-
6300 Series
3 Pages
-
7511 series
2 Pages
-
Model 93 110
1 Pages
-
Model 15H Hollow Bore
2 Pages
-
Model 732
4 Pages
-
Model 731
3 Pages
-
Model 711
4 Pages
-
Model 710
1 Pages
-
Model 720-6300
1 Pages
-
Model 29
1 Pages
-
Model 22
1 Pages
-
Model 20
1 Pages
-
MECHANICAL COUNTER 3602
2 Pages
-
Model 58
2 Pages
-
Model 49
2 Pages
-
Model 48
2 Pages
-
LengthMeasuring-Mechanical
2 Pages
-
9100
36 Pages
-
750
1 Pages
-
07
2 Pages
-
720
1 Pages
-
99
2 Pages
-
Model 44
1 Pages
-
model 40
2 Pages
-
Model 10
1 Pages
-
model 34
4 Pages
Archived catalogs
-
Power Meters
3 Pages
-
STAE
2 Pages