CTR52U

CTR52U

CTR52U

Product catalog summary
Specifications:
The CTR52U is a multipurpose device functioning as a counter, rate meter, and timer. It operates on a supply voltage of 10 to 30 V DC with reverse polarity protection and a maximum current consumption of 40 mA. The device features a 6-digit red 7-segment LED display, 8 mm high, and data is backed up using EEPROM. The housing dimensions are 48 x 24 mm, compliant with DIN 43 700 standards, and it is available in grey (RAL 7021). Inputs are programmable for npn or pnp polarity, with an input resistance of approximately 5 kΩ. The counting frequency can reach up to 60 kHz, adjustable to 30 Hz, with a reset time of 5 ms. The resolution ranges from 0.001 seconds to 999999 hours. Input switching levels vary between standard and 5 V versions, with accuracy under 0.1% for frequency display/rate meter.

Operating Modes:
The device supports multiple operating modes, including electronic totalizer and frequency counter, counter with two totalizing ranges, totalizer and timer, and timer with two time ranges.

Ordering Information:
The CTR52U series offers standard and 5V input levels. Accessories include NEMA4 wall mount enclosures and DIN Rail Mounting Frames.

Features:
The CTR52U is a universal device with dual functions, suitable as a maintenance counter. It includes two pulse or time counters for measuring daily and total values, a count frequency of 60 kHz, and four dual functions in one device, reducing inventory costs. It allows separate multiplication and scaling factors for pulse and frequency counters and can be programmed as Total/Tacho, 2 Totalizers, Total/Timer, or 2 Timers.

Environmental and Compliance:
The device operates in ambient temperatures from -20 to +50 °C and can be stored between -25 to +70 °C. It complies with EMC directive 89/36/EWG, with immunity to interference per EN 61000-6-4/EN 55 011 class B and emitted interference per EN 61000-6-2. It offers IP65 protection from the front and weighs approximately 50 g.

Connections and Delivery:
Connections include terminals for 10 to 30 V DC, 0 V GND, INP A, INP B, and Reset. The delivery includes a digital display, panel mounting clip, bezels for screw and clip mounting, a seal, and an instructions manual. The panel cut-out dimensions are specified for proper installation.
See more

Catalog excerpts

CTR52U-1

Multipurpose Device Counter, Rate Meter and Timer Features • Universal, with dual functions, also suitable as maintenance counter • 2 pulse or time counters for measuring daily and total values • Count frequency 60 kHz • Four dual functions in one device, saves on inventory costs • Separate multiplication and scaling factor for pulse & frequency counter • Combination Unit Can Be Programmed as: Total / Tacho 2 Totalizers Total / Timer 2 Timers Operating modes: Electronic totalizer and frequency counter, counter with 2 totalizing ranges, totalizer and timer, timer with 2 time ranges voltage: with reverse polarity protection Current consumption: max. 40 mA Display: 6 digit red 7 segment LED display; 8 mm high Data backup: EEPROM Housing: Dimensions 48 x 24 mm (1.89” x 0.945”) according to DIN 43 700; RAL 7021, grey Polarity of Inputs: programmable, npn or pnp for all inputs Input resistance: appr. 5 kQ Counting frequency: max. 60 kHz, can be damped to 30 Hz Reset time: 5 ms Resolution counter: 0.001 sec ...999999 hr Input switching level Standard version: Low: 0 to 0.2 x Input Power Voltage High: 0.6 x Input Power Voltage to 30VDC 5 V version: Low 0 ... 2 V DC High 12 ... 30 V DC Accuracy: <0.1 % (Frequency display/Rate meter) Ambient temperature: -20 ... +50 °C (14°F ... 158°F), non-condensing Storage temperature: -25 ... +70 °C (-13F ... 158F) EMC: according to EC EMC directive 89/36/EWG Immunity to interference: EN 61000-6-4/EN 55 011 class B Emitted interference: EN 61000-6-2 Protection: IP65 (from front) Weight: appr. 50 g Example CTR52U 0 Series: Input Level: 0= Standard A= 5V level Accessories NEMA4 wall mount enclosures available see NEMA-32 & LCN4X 32DINRAIL - DIN Rail Mounting Frame DR-4 - 4” DIN Rail RoHS Compliant

 Open the catalog to page 1
CTR52U-2

Delive 1 Digit 1 Pane 1 Beze 50 x 1 Beze 50 x 1 Seal 1 Instr Connections: 1 10 ... 30 V DC 2 0 V GND 3 INP A 4 INP B 5 Reset www.trumeter.com Includes: Delivery

 Open the catalog to page 2

All TRUMETER catalogs and technical brochures

  1. 99 Series

    2  Pages

  2. Model 750

    1  Page

  3. 46 Series

    2  Pages

  4. 29 Series

    2  Pages

  5. 22 Series

    2  Pages

  6. 20 Series

    1  Page

  7. 3602 Series

    2  Pages

  8. 9100 Series

    2  Pages

  9. 94 Series

    2  Pages

  10. 18 Series

    2  Pages

  11. Model 6300

    3  Pages

  12. Model 3400

    2  Pages

  13. 7111 | 7111HV

    2  Pages

  14. 7000/7000AS

    2  Pages

  15. 732 Series

    3  Pages

  16. 722 Series

    3  Pages

  17. 711 Series

    6  Pages

  18. CT Meter

    2  Pages

  19. Shunt Meter

    2  Pages

  20. 924K

    4  Pages

  21. B Series

    2  Pages

  22. BVA

    2  Pages

  23. CTF16/17

    2  Pages

  24. E660, E760

    2  Pages

  25. H37 Series

    1  Page

  26. H57

    1  Page

  27. HB26 Series

    2  Pages

  28. HC77

    1  Page

  29. 6300 Series

    3  Pages

  30. 7511 series

    2  Pages

  31. Model 93 110

    1  Page

  32. Model 732

    4  Pages

  33. Model 731

    3  Pages

  34. Model 711

    4  Pages

  35. Model 710

    1  Page

  36. Model 29

    1  Page

  37. Model 22

    1  Page

  38. Model 20

    1  Page

  39. Model 58

    2  Pages

  40. Model 49

    2  Pages

  41. Model 48

    2  Pages

  42. 9100

    36  Pages

  43. 750

    1  Page

  44. 07

    2  Pages

  45. 720

    1  Page

  46. 99

    2  Pages

  47. Model 44

    1  Page

  48. model 40

    2  Pages

  49. Model 10

    1  Page

  50. model 34

    4  Pages

Archived catalogs

  1. STAE

    2  Pages

  2. Power Meters

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.