924K
1 /4Pages

924K

924K
1 /4Pages

Catalog excerpts

924K-1

Features • Simultaneous display of the actual value, presets, batch count or total count • 2 Relay outputs • Annunciators for the displayed preset and for the output status • 3 predefined settings for the most common parameter settings • Direct entry into the programming • Tracking presets eliminate the need for reprogramming of the pre-signal • Minimum installation depth • 4 stage RESET modes • 3 stage key lockout Specifications Supply voltage: Display: Data retention: Inputs: Count inputs: Polarity of the inputs: Input resistance: Count frequency: Monitoring/reset inputs: Min pulse duration of the inputs: Switching levels with AC HTL-level Switching levels with DC HTL-level Pulse shape: 90 ... 260 V AC/max. 8 VA, 50/60 HZ, External fuse protection T 0,1 A 10 ... 30 V DC/max. 1,5 W External fuse protection T 0,2 A 2 line 2 x 6 digits LCD display LED Look: negative, red backlighting min. 10 years, EEPROM programmable for all inputs in common NPN/PNP 5 kOhm max. 55 kHz (details see manual) MPI, lock, gate, reset 10 ms/1 ms variable, Schmitt-Trigger characteristics Relay Reaction Switching voltage Switching current Switching current Switching capacity Mech. service life (switching cycles) 2 x 107 N° of switching cycles at 3 A/250 V AC 1 x 105 N° of switching cycles at 3 A/30 V DC 1 x 105 Relay closing contact, programmable as normally open (NO) or normally closed (NC) Mech. service life (switching cycles) 20 x 106 N° of switching cycles at 3 A/250 V AC 5 x 104 N° of switching cycles at 3 A/30 V DC 5 x 104 Relay with changeover contact Relay: appr. 7 ms Details see instruction manual Response time of the 100/600 ms, frequency counter: Details see instruction manual General: Count modes: Pulse counter: Frequency counter: Timer: cnt.dir, up.dn, up.up, quad, quad 2, quad 4, A/B, (A-B)/A x 100% A, A-B, A+B, quad, A/B, (A-B)/A x 100% FrErun, Auto, InpA.InpB., InpB.InpB.

 Open the catalog to page 1
924K-2

Voltage supply for sensors: AC supply 24 V DC± 15%, 80 mA DC supply max. 80 mA, external voltage supply is connected through Operating temperature: -20 °C ... +65 °C Humidity: RH 93% at +40 °C, non-condensing EMC: Device safety: Design to: Protection: Application area: UL (applied for): Protection: Weight: Interference emissions EN55011 Class B Interference resistance EN 61000-6-2 EN61010 Part 1 Class: 2 Soiling Level 2 File-N°.: E128604 IP65 (front) approx. 125 g Signal and control inputs 1 Sensor voltage supply AC: 24 VDC/80 mA DC: UB interconnected 2 GND (0 VDC) 3 INP A (Signal...

 Open the catalog to page 2
924K-3

Typical applications: Pulse counter Functions/ Count modes Application examples Count with direction mode Difference mode Quadrature mode quad/quad2/quad4 Add, Sub, automatic reset 2-input adding mode A+B Ratio measurement A/B Percentage difference measurement (A-B)/A x C ountDir Roller shutter door with automatic shutoff • Batch counting • Totaliser (Overall total) • Multiplication and division factor (up to 99.999) • Set value • Step or tracking preset Quad Running direction and position on milling machines UpDown Automatic subtraction of faulty or reject parts from the total piece count Batch...

 Open the catalog to page 3
924K-4

Areas of application: Frequency counter (Tachometer) Functions/ Count modes Application examples A—B Synchro monitoring and control of two conveyor belts Quad Speed regulation with indication of direction (A-B)/A [%] Ratio measurement e.g. for speed alignment Quad (Phase discriminator with recognition of direction) Averaging Start delay 2nd tacho input Gate input Multiplication and division factor ( up to 99.9999) Time and hours-run meter (Timer) Functions/ Count modes • FrErun (Control via gate input) • Auto (Start via Reset, Stop at preset) • npB.InpB (Start with first edge at InpB., Stop with...

 Open the catalog to page 4

All TRUMETER catalogs and technical brochures

  1. 99 Series

    2  Pages

  2. Model 750

    1  Page

  3. 46 Series

    2  Pages

  4. 29 Series

    2  Pages

  5. 22 Series

    2  Pages

  6. 20 Series

    1  Page

  7. 3602 Series

    2  Pages

  8. 9100 Series

    2  Pages

  9. 94 Series

    2  Pages

  10. 18 Series

    2  Pages

  11. Model 6300

    3  Pages

  12. Model 3400

    2  Pages

  13. 7111 | 7111HV

    2  Pages

  14. 7000/7000AS

    2  Pages

  15. 732 Series

    3  Pages

  16. 722 Series

    3  Pages

  17. 711 Series

    6  Pages

  18. CT Meter

    2  Pages

  19. Shunt Meter

    2  Pages

  20. B Series

    2  Pages

  21. BVA

    2  Pages

  22. CTF16/17

    2  Pages

  23. CTR52U

    2  Pages

  24. E660, E760

    2  Pages

  25. H37 Series

    1  Page

  26. H57

    1  Page

  27. HB26 Series

    2  Pages

  28. HC77

    1  Page

  29. 6300 Series

    3  Pages

  30. 7511 series

    2  Pages

  31. Model 93 110

    1  Page

  32. Model 732

    4  Pages

  33. Model 731

    3  Pages

  34. Model 711

    4  Pages

  35. Model 710

    1  Page

  36. Model 29

    1  Page

  37. Model 22

    1  Page

  38. Model 20

    1  Page

  39. Model 58

    2  Pages

  40. Model 49

    2  Pages

  41. Model 48

    2  Pages

  42. 9100

    36  Pages

  43. 750

    1  Page

  44. 07

    2  Pages

  45. 720

    1  Page

  46. 99

    2  Pages

  47. Model 44

    1  Page

  48. model 40

    2  Pages

  49. Model 10

    1  Page

  50. model 34

    4  Pages

Archived catalogs

  1. STAE

    2  Pages

  2. Power Meters

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.