Overview: This document provides comprehensive technical specifications and guidelines for TROX FK-EU fire dampers, designed to prevent fire and smoke spread through ductwork in buildings. These dampers comply with European regulations and offer optional ATEX certification for explosive atmospheres.
Specifications:
  • Nominal sizes range from 200x200 mm to 1500x800 mm, with casing lengths of 375 mm or 500 mm.
  • Options include explosion-proof construction and air transfer damper features.
  • Available in stainless steel or powder-coated casing for corrosion protection.
  • Integration with Building Management Systems (BMS) via TROXNETCOM.
Functional Description:
  • Fire dampers close automatically during a fire, triggered by a fusible link at 72°C or 95°C.
  • Spring return actuators enable motorized operation with limit switches for position indication.
  • Air transfer dampers include duct smoke detectors to prevent smoke spread before reaching release temperature.
Installation and Maintenance:
  • Installation kits are available for various wall types, including solid, lightweight partition, and shaft walls.
  • Regular maintenance and functional testing are required every six months, potentially extending to annual testing after successful consecutive tests.
Standards and Certifications:
  • Complies with EN 15650, EN 1366-2, EN 13501-3, and other relevant standards.
  • Hygiene compliance with VDI 6022 and other standards.
  • ATEX certification for explosive atmospheres, with specific zones and conditions outlined.
Optional Equipment and Accessories:
  • Electric actuators, duct smoke detectors, and various installation kits.
  • Flexible connectors, cover grilles, and circular spigots for enhanced functionality.
Special Characteristics:
  • Low differential pressure and sound power level.
  • Corrosion protection and closed blade air leakage compliance.
  • Easy integration into central BMS and straightforward electrical connections.
Design Information:
  • Approved for use in ventilation and air conditioning systems only.
  • Performance class up to EI 120 (ve, ho, i ↔ o) S achievable with specific configurations.
  • Installation must follow the operating and installation manual.
Incorrect Use:
  • Not to be used without approved attachments in explosive atmospheres.
  • Not suitable as a smoke control damper or for outdoor use without weather protection.
Correct Use:
  • Specific installation methods and materials required for solid walls, ceiling slabs, and lightweight partition walls.
Installation Orientation:
  • Details on installation orientation with horizontal ducts and as an air transfer damper.
Order Code and Examples:
  • Detailed order codes for different configurations of fire dampers.
Accessories and Installation Kits:
  • Various kits available for different wall types and installation methods.
Materials and Surfaces:
  • Installation kits and subframes made from galvanized steel and special insulation materials.
Installation Kit for Fire Dampers: Essential for mounting fire dampers on solid ceiling slabs, ensuring sealing integrity during subsidence. Includes an extension piece and a U-channel, pre-assembled at the factory.
Cover Grille: Used when only one end of the damper is ducted, providing approximately 70% free area.
Circular Spigot: Facilitates direct connection to circular ducts, made of galvanized sheet steel.
Flexible Connector: Recommended for installations in lightweight walls and fire walls to accommodate expansion and deformation during a fire.
Extension Piece: Required when using cover grilles, circular spigot plates, or flexible connectors.
Limit Switch: Indicates damper blade position (OPEN/CLOSED) and available in explosion-proof versions.
Spring Return Actuator: Allows remote control of the fire damper and closes the damper if the supply voltage fails.
Air Transfer Damper: Allows remote control and closes upon smoke detection or power failure, suitable for airflow velocities from 1 to 20 m/s.
Specifications: Includes details on duct smoke detectors and fire dampers, focusing on integration into building safety systems.
Procedures and Standards:
  • LON System: Ensures product compatibility through a uniform protocol.
  • AS-i Interface: Global standard bus system for sending control signals.
Recommendations:
  • Ensure proper installation and wiring of modules outside potentially explosive atmospheres.
  • Utilize the Easy Product Finder for project-specific product sizing.
Data and Sizing Examples:
  • Tables for quick sizing of fire dampers based on volume flow rate and sound power level.
See more

Catalog excerpts

Type FK-EU-1

Fire dampers Type FK-EU FK-EU with fusible link for 72 °C or 95 °C CE compliant according to European regulations With TROXNETCOM as an option For diverse applications Rectangular fire damper for the isolation of duct penetrations between fire compartments, for a variety of installation situations, available in many different sizes and constructions ■ Nominal sizes 200 × 200 – 1500 × 800 mm, in increments of 1 mm ■ Low differential pressure and sound power level ■ Explosion-proof construction (ATEX) as an option ■ Air transfer damper as an option ■ Optional stainless steel casing or powder-coated casing for increased corrosion protection ■ Integration into the central BMS with TROXNETCOM ATEX certification Optional equipment and accessories ■ Electric actuator 24 V/230 V ET ■ Universal installation options ■ Release temperature 72/95 °C ■ Duct smoke detector RM-O-3-D

 Open the catalog to page 1
Type FK-EU-2

Fire dampers Type Page Installation kit - installation in solid walls 1.1 - 16 Installation kit - installation with flexible ceiling joint 1.1 - 18 Installation kit - for installation on the face of solid walls 1.1 - 19 Installation kit - for installation adjacent to solid walls 1.1 - 20 Installation kit - for installation remote from solid walls 1.1 - 21 Installation kit - for installation in lightweight partition 1.1 - 23 walls/fire walls Cover grille 1.1 - 25 Spring return actuator 1.1 - 34 Duct smoke detectors 1.1 - 37...

 Open the catalog to page 2
Type FK-EU-3

Fire dampers General information FK-EU with fusible link FK-EU with spring return actuator FK-EU with spring return actuator (explosion-proof) FK-EU as air transfer damper Product examples

 Open the catalog to page 3
Type FK-EU-4

Fire dampers General information Fire damper Type FK-EU For detailed information on attachments see Chapter K4 – 1.2. Application – TROX fire dampers of Type FK-EU, with CE marking and declaration of performance, for the isolation of duct penetrations between fire compartments in the event of a fire – To prevent the propagation of fire and smoke through ductwork to adjacent designated fire compartments Classification – Class of performance to EN 13501-3, up to EI 180 (ve, ho, i ↔ o) S Variants – With fusible link – With fusible link for use in potentially explosive atmospheres – With spring return...

 Open the catalog to page 4
Type FK-EU-5

Fire dampers Construction features - Rectangular or square construction, rigid casing, both flanges with fixing holes - Suitable for the connection of ducts, spigots, flexible connectors or a cover grille - The release mechanism is accessible and can be tested from the outside - Two inspection access panels - Remote control with spring return actuator Materials and surfaces Casing: - Galvanised sheet steel - Galvanised sheet steel, powder-coated RAL 7001 - Stainless steel 1.4301 Damper blade: - Special insulation material - Special insulation material with coating Other components: - Damper blade...

 Open the catalog to page 5
Type FK-EU-6

Fire dampers General information Functional description In the event of a fire, fire dampers shut automatically to prevent the propagation of fire Construction with fusible link and smoke through ductwork to adjacent designated fire compartments. In the event of a fire, the damper is triggered at 72 °C or at 95 °C (use in warm air ventilation systems) by a fusible link. The release mechanism is accessible and can be tested from the outside. Schematic illustration of FK-EU with fusible link ① Casing ② Damper blade ③ Travel stop for OPEN position ④ Travel stop for CLOSED position ⑤ Inspection access...

 Open the catalog to page 6
Type FK-EU-7

Fire dampers General information Function Construction with spring return actuator Functional description The spring return actuator enables the motorised opening and closing of the damper blade; it can be activated by the central BMS. In the event of a fire, the damper is triggered thermoelectrically at 72 °C or 95 °C (use in warm air ventilation systems). As long as power is supplied to the actuator, the damper blade remains open. If the supply voltage fails, the damper closes (power off to close). Motorised fire dampers can be used to shut off ducts. The torque of each actuator is sufficient...

 Open the catalog to page 7
Type FK-EU-8

Fire dampers Function 1 Construction with spring return actuator, explosion-proof Functional description The fire damper is used as a shut-off device to prevent fire and smoke from spreading through ducting in areas with potentially explosive atmospheres. The fire damper is suitable for supply air and extract air systems in potentially explosive atmospheres. For the operation of the fire damper, the operating and installation manual and the technical data in the additional operating manual must be observed. Use in areas with potentially explosive atmospheres (ATEX) According to declaration of...

 Open the catalog to page 8
Type FK-EU-9

Fire dampers General information Function Air transfer damper Functional description Air transfer dampers are designed to shut off openings for air transfer in fire resistant internal walls and ceiling slabs. To prevent smoke from spreading in buildings, it is extremely important that the smoke is detected at an early stage. Duct smoke detector Type RM-O-3-D is required to control and trigger the air transfer damper. The smoke detector operates on the principle of light scattering and detects the smoke regardless of its temperature so that the fire dampers can be closed before the release temperature...

 Open the catalog to page 9
Type FK-EU-10

Fire dampers FK-EU Design information – Approved only for use in ventilation and air conditioning sytems – A class of performance up to EI 120 (ve, ho, i ↔ o) S can only be achieved with ducts connected on both ends, or with a duct on one end and a cover grille on the other end. – If the fire damper is installed in a solid wall, solid ceiling slab, lightweight partition wall or shaft wall with a lower fire resistance class than that of the fire damper, the fire resistance class of the wall or ceiling slab applies also to the FK-EU (details upon request) – Ducting must be installed in such a manner...

 Open the catalog to page 10

All TROX catalogs and technical brochures

  1. Type KA-EU

    21  Pages

  2. Type XSA

    21  Pages

  3. Type MSA

    21  Pages

  4. Type DLQ

    20  Pages

  5. Type DCS

    24  Pages

  6. Type FD

    22  Pages

  7. DID642

    22  Pages

  8. DID632

    25  Pages

  9. DID300B

    24  Pages

  10. DID312

    22  Pages

  11. DID614

    17  Pages

  12. Control_units

    626  Pages

  13. Type FD

    35  Pages

  14. JZ-HL

    19  Pages

  15. JZ-LL

    23  Pages

  16. JZ-HL-AL

    16  Pages

  17. JZ-AL

    15  Pages

  18. JZ-LL-AL

    16  Pages

  19. Filter Media

    16  Pages

  20. Jet nozzles

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.