JZ-HL-AL
16Pages

{{requestButtons}}

Catalog excerpts

JZ-HL-AL - 1

Multileaf dampers Type JZ-HL-AL Multileaf dampers made of aluminium for low-leakage ​ shut-off in air conditioning systems Rectangular multileaf dampers for volume flow and pressure control as well as for ​ low-leakage shut-off of ducts and openings in walls and ceiling slabs ■■ Maximum dimensions 1200 × 1000 mm ■■ Closed blade air leakage to EN 1751, class 2 ■■ Casing air leakage to EN 1751, class C ■■ Aerofoil opposed action blades ■■ Blades interconnected by gears ■■ Available in standard sizes and many intermediate sizes Optional equipment and accessories ■■ Actuators: Open/Close actuators, modulating actuators ■■ Powder-coated construction ■■ Anodised construction

Open the catalog to page 1
JZ-HL-AL - 2

Multileaf dampers General information Type JZ-HL-AL Page General information Function Technical data Quick sizing Specification text Order code Attachments Dimensions and weight Product details Installation details Basic information and nomenclature Application – Multileaf dampers of Type JZ-HL-AL are used ​ as an acting element in the volume flow and ​ pressure control in air conditioning systems – For low-leakage shut-off of ducts and openings ​ in walls and ceiling slabs – Powder-coated construction with increased ​ corrosion resistance if required Special characteristics – Aerofoil...

Open the catalog to page 2
JZ-HL-AL - 3

Multileaf dampers 09/2017 - DE/en TROX ®TECHNIK

Open the catalog to page 3
JZ-HL-AL - 4

Multileaf dampers JZ-HL-AL The internal gears transfer the synchronous ​ rotational movement from the drive arm to the ​ individual blades. Functional description Multileaf dampers with gears can only have ​ opposed action blades. Schematic illustration of JZ-HL-AL ① Casing ② Blade tip seal ③ Opposed blades ④ Gears ⑤ Bearing plate with quadrant stay ⑥ Actuator

Open the catalog to page 4
JZ-HL-AL - 5

Multileaf dampers The torque for closing a multileaf damper must be such that the damper can be safely opened and closed. For closure, the torque must suffice to ensure complete shut-off by the blades. Opening is initiated without aerodynamic forces. When air flows through the damper, the aerodynamic forces of the airflow create a closing force (torque) on the blades; this happens independent of the direction of the airflow. This closing force must be countered, or overcome. The blade position, or blade angle a, for which there is the largest torque depends, among other factors, on the fan...

Open the catalog to page 5
JZ-HL-AL - 6

Multileaf dampers Quick sizing Quick sizing tables provide a good overview of the sound power levels and differential pressures that can be expected. Approximate intermediate values can be interpolated. Precise intermediate values and spectral data can be calculated with our Easy Product Finder design programme. The sound power levels LWA apply to multileaf dampers with a cross-sectional area (B x H) of 1 m2. The differential pressures apply to multileaf dampers installed in ducts (installation type A). JZ-HL-AL, quick sizing - differential pressure and sound power level Installation type A...

Open the catalog to page 6
JZ-HL-AL - 7

Multileaf dampers Specification text This specification text describes the general ​ properties of the product. Texts for variants can be ​ generated with our Easy Product Finder design ​ programme. Rectangular multileaf dampers for volume flow ​ and pressure control as well as for low-leakage ​ shut-off of ducts and openings in walls and ceiling ​ slabs. Ready-to-operate unit which consists of the ​ casing, aerofoil blades and the blade mechanism. Flanges on both sides, suitable for duct ​ connection. The blade position is indicated externally by a ​ notch in the blade shaft extension....

Open the catalog to page 7
JZ-HL-AL - 8

Multileaf dampers Order code  Type JZ-HL-AL Low-leakage multileaf damper ​ made of aluminium, closed blade air ​ leakage to EN 1751, class 2  Nominal size [mm] B × H  Installation subframe No entry: none ER With installation subframe  Attachments Z04 Quadrant stay Z05 – Z07 Quadrant stay and limit switches Z12 – Z51 Actuators ZF01 – ZF15 Spring return actuators Z60 – Z77 Pneumatic actuators  Damper blade safety function Only for spring return actuators or ​ pneumatic actuators NO Pressure off/power off to OPEN NC Pressure off/power off to CLOSE  Surface No entry: standard construction...

Open the catalog to page 8
JZ-HL-AL - 9

Multileaf dampers Quadrant stays and limit switches Order code detail Z04 Z05 Z06 Z07 Open/Close actuators Order code detail Quadrant stay Quadrant stay Quadrant stay Quadrant stay Limit switch Function Damper blade position CLOSED Damper blade position OPEN Damper blade positions CLOSED nad OPEN Supply voltage Auxiliary switch Minimum torque of multileaf damper has to be considered when selecting the actuator. Open/Close actuators, fast-running Order code detail ZS21 ZS22 Open/Close actuators, spring return Order code detail Supply voltage Supply voltage on/off Supply voltage on/off Supply...

Open the catalog to page 9
JZ-HL-AL - 10

Multileaf dampers Damper blade safety ​ function – Power off to close/open Power off to close/open – Power off to close/open Power off to close/open – Power off to close/open Power off to close/open – Power off to close/open Power off to close/open Z60 – Z65: At 1.2 bar operating pressure only up to height H ≤ 650 mm Single acting pneumatic actuators Order ​ Mea­ code detail ning Z72 Damper blade safety function Power off and pressure off to close/​ open Power off and pressure off to close/​ open

Open the catalog to page 10
JZ-HL-AL - 11

Multileaf dampers JZ-HL-AL, standard sizes JZ-AL, JZ-HL-AL, standard sizes H Position of drive shaft JZ-HL-AL, intermediate sizes

Open the catalog to page 11
JZ-HL-AL - 12

Multileaf dampers

Open the catalog to page 12
JZ-HL-AL - 13

Multileaf dampers Product details – Drive shafts (special accessory) upon request Aluminium multileaf dampers, corner holes B + 76

Open the catalog to page 13
JZ-HL-AL - 14

Multileaf dampers Product details JZ-LL-AL, JZ-HL-AL, drive shafts ® Standard shaft @ ZS991 - square shaft 9 mm @ ZS99 - extended drive shaft PD - HLAL - 14 TROX ®TECHNIK

Open the catalog to page 14
JZ-HL-AL - 15

Multileaf dampers Installation details Installation and commissioning – With horizontal or vertical blades – With or without installation subframe – Torsion-free installation – Only for installation in internal spaces Wall installation without installation subframe Duct installation

Open the catalog to page 15

All TROX catalogs and technical brochures

  1. Type KA-EU

    21 Pages

  2. Type FK-EU

    52 Pages

  3. Type XSA

    21 Pages

  4. Type MSA

    21 Pages

  5. Type DLQ

    20 Pages

  6. Type DCS

    24 Pages

  7. Type FD

    22 Pages

  8. DID642

    22 Pages

  9. DID632

    25 Pages

  10. DID300B

    24 Pages

  11. DID312

    22 Pages

  12. DID614

    17 Pages

  13. Control_units

    626 Pages

  14. Type FD

    35 Pages

  15. JZ-HL

    19 Pages

  16. JZ-LL

    23 Pages

  17. JZ-AL

    15 Pages

  18. JZ-LL-AL

    16 Pages

  19. Filter Media

    16 Pages

  20. Jet nozzles

    12 Pages