Catalog excerpts
Multileaf dampers Type JZ-AL Multileaf dampers made of aluminium for shutting off the airflow in air conditioning systems Rectangular multileaf dampers for volume flow and pressure control as well as for shutting off ducts and openings in walls and ceiling slabs ■■ Maximum dimensions 1200 × 1000 mm ■■ Casing air leakage to EN 1751, class C ■■ Aerofoil opposed action blades ■■ Blades interconnected by gears Optional equipment and accessories ■■ Actuators: Open/Close actuators, modulating actuators ■■ Powder-coated construction ■■ Anodised construction Blade mechanism with g
Open the catalog to page 1Multileaf dampers General information Type JZ-AL Page General information Function Technical data Quick sizing Specification text Order code Attachments Dimensions and weight Product details Installation details Basic information and nomenclature Application – Multileaf dampers of Type JZ-AL are used as an acting element in the volume flow and pressure control in air conditioning systems – For shutting off ducts and openings in walls and ceiling slabs – Opposed action blades are due to their characteristics preferably used for variable operation – Powder-coated construction with...
Open the catalog to page 2Multileaf dampers JZ-AL The internal gears transfer the synchronous rotational movement from the drive arm to the individual blades. Functional description Multileaf dampers with gears can only have opposed action blades. Schematic illustration of JZ-AL ① Casing ② Opposed blades ③ Gears ④ Actuator ⑤ Bearing plate and drive shaft
Open the catalog to page 3Multileaf dampers The torque for closing a multileaf damper must be such that the damper can be safely opened and closed. For closure, the torque must suffice to ensure complete shut-off by the blades. Opening is initiated without aerodynamic forces. When air flows through the damper, the aerodynamic forces of the airflow create a closing force (torque) on the blades; this happens independent of the direction of the airflow. This closing force must be countered, or overcome. The blade position, or blade angle a, for which there is the largest torque depends, among other factors, on the fan...
Open the catalog to page 4Multileaf dampers Quick sizing Quick sizing tables provide a good overview of the sound power levels and differential pressures that can be expected. Approximate intermediate values can be interpolated. Precise intermediate values and spectral data can be calculated with our Easy Product Finder design programme. The sound power levels LWA apply to multileaf dampers with a cross-sectional area (B x H) of 1 m2. The differential pressures apply to multileaf dampers installed in ducts (installation type A). JZ-AL, differential pressure and sound power level Installation type A Installation type...
Open the catalog to page 5Multileaf dampers Specification text This specification text describes the general properties of the product. Texts for variants can be generated with our Easy Product Finder design programme. Rectangular multileaf dampers for volume flow and pressure control as well as for shutting off ducts and openings in walls and ceiling slabs. Ready-to-operate unit which consists of the casing, aerofoil blades and the blade mechanism. Flanges on both sides, suitable for duct connection. The blade position is indicated externally by a notch in the blade shaft extension. Casing air...
Open the catalog to page 6Multileaf dampers Order code Type JZ-AL Aluminium multileaf damper Nominal size [mm] B × H Installation subframe No entry: none ER With Attachments No entry: none Z04 – Z07 Quadrant stay Z12 – Z51 Actuators ZF01 – ZF15 Spring return actuators Z60 – Z77 Pneumatic actuators Damper blade safety function Only for spring return actuators or pneumatic actuators NO Pressure off/power off to OPEN NC Pressure off/power off to CLOSE Surface No entry: standard construction P1 Powder-coated, specify RAL CLASSIC colour PS Powder-coated, specify DB colour S3 Anodised to EURAS standard,...
Open the catalog to page 7Multileaf dampers Quadrant stays and limit switches Order code detail Z04 Z05 Z06 Z07 Open/Close actuators Order code detail Quadrant stay Quadrant stay Quadrant stay Quadrant stay Limit switch Function Damper blade position CLOSED Damper blade position OPEN Damper blade positions CLOSED nad OPEN Supply voltage Auxiliary switch Minimum torque of multileaf damper has to be considered when selecting the actuator. Open/Close actuators, fast-running Order code detail ZS21 ZS22 Open/Close actuators, spring return Order code detail Supply voltage Supply voltage on/off Supply voltage on/off Supply...
Open the catalog to page 8Multileaf dampers Damper blade safety function – Power off to close/open Power off to close/open – Power off to close/open Power off to close/open – Power off to close/open Power off to close/open – Power off to close/open Power off to close/open Z60 – Z65: At 1.2 bar operating pressure only up to height H ≤ 650 mm Single acting pneumatic actuators Order Mea code detail ning Z72 Damper blade safety function Power off and pressure off to close/ open Power off and pressure off to close/ open
Open the catalog to page 9Multileaf dampers JZ-AL, standard sizes JZ-AL, JZ-HL-AL, standard sizes H Position of drive shaft JZ-AL, intermediate sizes
Open the catalog to page 10Multileaf dampers JZ-AL, JZ-HL-AL, intermediate sizes 09/2017 - DE/en TROX ®TECHNIK
Open the catalog to page 11Multileaf dampers Product details – Drive shafts (special accessory) upon request Aluminium multileaf dampers, corner holes B + 76
Open the catalog to page 12Multileaf dampers Product details JZ-AL, drive shafts ① Standard shaft ② ZS99 – extended drive shaft
Open the catalog to page 13Multileaf dampers Installation details Installation and commissioning – With horizontal or vertical blades – With or without installation subframe – Torsion-free installation – Only for installation in internal spaces Wall installation without installation subframe Duct installation
Open the catalog to page 14Multileaf dampers Basic information and nomenclature Principal dimensions B [mm] Duct width H [mm] Duct height JZ-AL n [ ] Number of flange screw holes M [kg] Weight section (B × H) LWA [dB(A)] A-weighted sound power level of air-regenerated noise for the multileaf damper [m³/h] and [l/s] Volume flow rate α [°] Damper blade position, 0°: OPEN, 90°: CLOSED A [m²] Upstream cross section v [m/s] Airflow velocity based on the upstream cross Δpst [Pa] Static differential pressure Δpst max [Pa] Maximum static differential pressure All sound power levels are b
Open the catalog to page 15All TROX catalogs and technical brochures
-
Type KA-EU
21 Pages
-
Type FK-EU
52 Pages
-
Type XSA
21 Pages
-
Type MSA
21 Pages
-
Type DLQ
20 Pages
-
Type DCS
24 Pages
-
Type FD
22 Pages
-
Swirl Diffuser VDW
2 Pages
-
Air terminal devices
4 Pages
-
DID642
22 Pages
-
DID632
25 Pages
-
DID300B
24 Pages
-
DID312
22 Pages
-
DID614
17 Pages
-
Impulse diffusers Type ISH
15 Pages
-
Control_units
626 Pages
-
Type FD
35 Pages
-
Ceiling swirl diffusers Type FD
22 Pages
-
JZ-HL
19 Pages
-
JZ-LL
23 Pages
-
JZ-HL-AL
16 Pages
-
JZ-LL-AL
16 Pages
-
Displacement Flow Diffusers
32 Pages
-
Air-water systems Design manual
60 Pages
-
Volume Flow Limiter
6 Pages
-
High Efficiency Terminal Filters
12 Pages
-
High efficiency air filter
9 Pages
-
Volume Flow Controller
12 Pages
-
Rectangular fire damper
16 Pages
-
Smoke Detector
7 Pages
-
Filter Media
16 Pages
-
Bag Filter Inserts
5 Pages
-
Volume Flow Controller
12 Pages
-
Jet nozzles
12 Pages