General Information
The DID632 is an active chilled beam designed for integration into various ceiling systems, suitable for room heights up to 4.0 meters. It is particularly effective for grid ceilings with sizes 600 or 625. The system uses a 2-pipe or 4-pipe heat exchanger to provide heating and cooling with low primary air volume flow rates and sound levels. The unit features adjustable air control blades and a hinged, removable induced air grille available in four designs.
Specifications
The DID632 offers high heating and cooling capacities with a maximum cooling capacity of 2450 W and heating capacity of 2970 W. It supports nominal lengths ranging from 900 mm to 3000 mm and operates at a maximum pressure of 6 bar and temperature of 75°C. The primary air volume flow rate ranges from 6 to 85 l/s or 22 to 306 m³/h.
Construction and Materials
The unit is constructed from galvanized sheet steel with a powder-coated finish in RAL 9010 or other RAL colors. The heat exchanger consists of copper tubes and aluminum fins, and the air control blades are made of flame-retardant polypropylene.
Variants and Options
Variants include different grille designs (perforated sheet metal with circular or square holes, longitudinal or transverse blades) and nozzle sizes (small, medium, large, extra-large). Optional features include a control system, additional casing for extract air, and adjustable air control blades.
Standards and Certification
The DID632 is Eurovent certified and conforms to VDI 6022 hygiene standards, ensuring compliance with ventilation and air-conditioning system requirements.
Installation and Maintenance
The unit is designed for easy installation with four suspension points and requires minimal maintenance due to the absence of moving parts. The heat exchanger can be cleaned with an industrial vacuum cleaner if necessary.
Performance and Adjustments
Air control blades allow for adjusting the air discharge pattern to optimize airflow according to room geometry. Blades can be adjusted up to 45° to the right or left in steps of 15°. Factory settings are for straight air discharge; adjustments can affect water-side capacity slightly.
Heat Exchanger Details
Maximum water-side operating pressure is 6 bar. Maximum water flow temperature for heating is 75°C, reduced to 55°C if flexible hoses are used. Cooling circuit water flow temperature should be at least 16°C to avoid falling below the dew point. 2-pipe systems are used for either heating or cooling, while 4-pipe systems can handle both simultaneously.
Order Examples
Examples include configurations with different grille designs, heat exchanger types, nozzle sizes, and casing arrangements, demonstrating the flexibility and customization options available for the DID632.
See more

Catalog excerpts

DID632-1

Induction units for suspen­ ded ceilings Type DID632 DID632, hinged induced ​ air grille Active chilled beam with two-way air discharge and ​ horizontal heat exchanger, suitable for grid ceilings ​ with grid size 600 or 625 Active chilled beam for heating and cooling, with 2-pipe or 4-pipe heat exchanger, for ​ integration with various ceiling systems ■■ Preferably for room heights up to 4.0 m Eurovent certification ■■ High heating and cooling capacity with a low conditioned primary air volume ​ flow rate and low sound power level ■■ Four nozzle variants to optimise induction based on demand ■■ Hinged, removable induced air grille in four designs Optional equipment and accessories ■■ Control system ■■ Additional casing for extract air ■■ Heat exchanger powder-coated black ■■ Powder coating in many different colours, e.g. RAL CLASSIC ■■ Adjustable air control blades for air direction control ■■ With an extended border also suitab

 Open the catalog to page 1
DID632-2

Induction units for suspended ceilings General information Technical data Quick sizing Specification text Order code Installation examples Installation details Basic information and nomenclature General information Function Application – Active chilled beams of Type DID632 for the ​ integration into various ceiling systems, ​ preferably for room heights up to 4.0 m – Particularly suitable for grid ceilings with grid ​ size 600 or 625 – Adjustable air control blades (optional) allow ​or f the manual adjustment of the air discharge ​ direction – 2-pipe or 4-pipe heat exchangers enable good ​ comfort...

 Open the catalog to page 2
DID632-3

Induction units for suspended ceilings General information seal – Adjustable air control blades for air direction ​ control Useful additions – Connecting hoses – Control equipment consisting of a control panel ​ including a controller with integral room ​ temperature sensor; valves and valve ​ actuators; and lockshields – X-AIRCONTROL control system Construction features – Spigot is suitable for circular ducts to EN 1506 ​ or EN 13180 – Four suspension points for on-site installation ​ (by others) – Four nozzle variants to optimise induction ​ based on demand – Optional additional casing with...

 Open the catalog to page 3
DID632-4

Induction units for suspended ceilings Functional description Active chilled beams provide centrally conditioned ​ primary air (fresh air) to the room and use heat ​ exchangers for additional cooling and/or heating. The primary air is discharged through nozzles (in ​ 4 sizes) into the mixing chambers; as a result of ​ this, secondary air is induced. Secondary air ​ (room air) is induced via the induced air grille and ​ passes through the horizontal heat exchanger, ​ where it is heated or cooled. Primary and secondary air mix and are then ​ supplied to the room horizontally through the ​ supply...

 Open the catalog to page 4
DID632-5

Induction units for suspended ceilings ① Conditioned fresh air (primary air) ② Supply air

 Open the catalog to page 5
DID632-6

Induction units for suspended ceilings Technical data Nominal length Length Height Width Primary air spigot, diameter Primary air volume flow rate Cooling capacity Heating capacity Max. operating pressure, water side Max. operating temperature

 Open the catalog to page 6
DID632-7

Induction units for suspended ceilings The quick sizing table contains operating points for defined reference units. For other operating points you may use the Easy Product Finder design software. 02/2017 - DE/en TROX ®TECHNIK

 Open the catalog to page 7
DID632-8

Induction units for suspended ceilings

 Open the catalog to page 8
DID632-9

Induction units for suspended ceilings Quick sizing 02/2017 - DE/en TROX ®TECHNIK

 Open the catalog to page 9
DID632-10

Induction units for suspended ceilings

 Open the catalog to page 10
DID632-11

Induction units for suspended ceilings Specification text This specification text describes the general ​ properties of the product. Texts for variants can be ​ generated with our Easy Product Finder design ​ programme. Active chilled beams of Type DID632, with two-​ way air discharge and high thermal output, ​ providing high thermal comfort levels. For installation flush with the ceiling, preferably in ​ rooms with a height up to 4.0 m. The units consist of a casing with suspension ​ points, a spigot, non-combustible nozzles, and a ​ horizontal heat exchanger. Nozzles in four sizes to optimise...

 Open the catalog to page 11
DID632-12

Induction units for suspended ceilings Order code  Type DID632 Active chilled beam  Induced air grille GL Longitudinal blades GQ Transverse blades LR Perforated metal, circular holes LQ Perforated metal, square holes  Heat exchanger 2 2-pipe 4 4-pipe  Nozzle variant Z Small plus M Medium G Large U Extra large  Arrangement of casings and connections LL (also available as supply and extract air ​ combination) LR ML MR RL RR (also available as supply and extract air ​ combination) Note L = left side, R = right side, M = centre  Additional casing with extract air spigot No entry: none AV Front...

 Open the catalog to page 12
DID632-13

Induction units for suspended ceilings Order code Order examples DID632–LR–2–M–LL/1193×1200×593 Perforated metal, circular holes 2-pipe Medium Left side, left side 1193 × 1200 mm 593 mm Induced air grille Heat exchanger Nozzle variant Arrangement of casings and connections Total length (diffuser face) × nominal length Width of front frame DID632–GQ–2–U–RR–AV–A1/1798×1200×598/P1/RAL9006/G3/LE/VS Induced air grille Heat exchanger Nozzle variant Arrangement of casings and connections Extract air spigot Water connections Total length (diffuser face) × nominal length Width of front frame Exposed surface...

 Open the catalog to page 13
DID632-14

Induction units for suspended ceilings

 Open the catalog to page 14
DID632-15

Induction units for suspended ceilings Set of air control blades If a high cooling capacity is required in a very ​ small space with active chilled beams, optional air ​ control blades allow for adjusting the air discharge ​ pattern such that the acceptable air velocity in the ​ occupied zone is not exceeded. The airflow of ​ each active chilled beam is spread and ​ discharged according to the room geometry. If the ​ use of a room changes, the air discharge pattern ​ can be optimised by adjusting the air control ​ blades accordingly. – It is possible to adjust several air control blades ​ (i.e....

 Open the catalog to page 15

All TROX catalogs and technical brochures

  1. Type KA-EU

    21  Pages

  2. Type FK-EU

    52  Pages

  3. Type XSA

    21  Pages

  4. Type MSA

    21  Pages

  5. Type DLQ

    20  Pages

  6. Type DCS

    24  Pages

  7. Type FD

    22  Pages

  8. DID642

    22  Pages

  9. DID300B

    24  Pages

  10. DID312

    22  Pages

  11. DID614

    17  Pages

  12. Control_units

    626  Pages

  13. Type FD

    35  Pages

  14. JZ-HL

    19  Pages

  15. JZ-LL

    23  Pages

  16. JZ-HL-AL

    16  Pages

  17. JZ-AL

    15  Pages

  18. JZ-LL-AL

    16  Pages

  19. Filter Media

    16  Pages

  20. Jet nozzles

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.