Catalog excerpts
Product data sheet Disc valves Z-LVS Circular disc valves with manually adjustable annular gap ■ Nominal sizes 100, 125, 160, 200 mm ■ Volume flow rate range 10 – 90 l/s or 36 – 324 m³/h ■ Diffuser face made of formed sheet steel, powder-coated ■ For variable and constant volume flows ■ For ceiling and wall installation ■ Easy to install ■ Volume flow rate balancing by simply turning the valve disc ■ Inexpensive solution for small rooms
Open the catalog to page 1Product data sheet General information Function Technical data Quick sizing Specification text Order code Dimensions Product details Nomenclature General information Application ▪ Disc valves are used as supply air devices in small rooms ▪ Horizontal radial supply air discharge ▪ For variable and constant volume flows ▪ For room heights up to 4 m (lower edge of suspended ceiling) ▪ For walls and suspended ceilings Special features ▪ Continuous volume flow rate balancing by turning the valve disc ▪ Easy to install Nominal sizes ▪ 100, 125, 160, 200 Parts and characteristics ▪ Valve disc with...
Open the catalog to page 2Product data sheet Function Supply air valves direct the air from air conditioning systems into the room. The resulting airflow induces high levels of room air, thereby rapidly reducing the airflow velocity and the temperature difference between supply air and room air. The result is a mixed flow ventilation in comfort zones, with good overall room ventilation, creating only very little turbulence in the occupied zone. Type Z-LVS disc valves have a valve disc that can be turned. Horizontal air discharge is radial. This valve disc facilitates volume flow rate balancing for commissioning....
Open the catalog to page 3Product data sheet Technical data Nominal sizes Minimum volume flow rate Maximum volume flow rate Quick sizing Quick sizing tables provide a good overview of the volume flow rates and corresponding sound power levels and differential pressures. Z-LVS/100, Z-LVS/125, sound power level and total differential pressure NS Z-LVS/160, Z-LVS/200, sound power level and total differential pressure NS Sizing example Given data qv = 20 l/s (72 m³/h) Supply air valve Maximum sound power level 32 dB(A) Quick Sizing Type Z-LVS Selectable nominal sizes: 100, 125, 160 Selected: Z-L
Open the catalog to page 4Product data sheet Specification text This specification text describes the general characteristics of the product. Texts for variants can be generated with our Easy Product Finder design program. Specification text Circular disc valves as supply air devices, preferably for small rooms. For installation into walls and suspended ceilings. Ready-to-install component which consists of a valve casing with cross bar, a valve disc with threaded spindle, and an installation subframe. The valve disc can be turned for volume flow rate balancing. The valve setting can be fixed with a lock nut. Spigot...
Open the catalog to page 5Product data sheet Order code Z-LVS / 160 | | 1 2 1 Type Z-LVS Disc valve 2 Nominal size [mm] 100, 125, 160, 200 Order example: Z-LVS/160 nominal size
Open the catalog to page 6Product data sheet Dimensions Z-LVS Installation subframe for LVS and Z-LVS ØD₁
Open the catalog to page 7Product data sheet Product details Installation and commissioning ▪ Installation flush with the wall or ceiling ▪ Perform volume flow rate balancing by turning the valve disc, then tighten the lock nut to fix the valve disc in the required position These are only schematic diagrams to illustrate installation details. Installation flush with the wall or ceiling, with installation subframe Setting range 0 Nominal size 100: max = 12 mm Nominal size 125: max = 15 mm Nominal size 160, 200: max = 20 mm
Open the catalog to page 8Product data sheet Nomenclature NS [mm] Nominal size ØD [mm] Outer diameter of the spigot LWA [dB(A)] A-weighted sound power level of air-regenerated noise ØD₁ [mm] Outer diameter of a circular diffuser face qv [m³/h]; [l/s] Volume flow rate L₁ [mm] Length of the face cover ring Δtz [K] Supply air to room air temperature difference, i.e. supply air temperature minus room temperature L₂ [mm] Installed length A [m²] Upstream cross section Δpt [Pa] Total differential pressure All sound power levels are based on 1 pW.
Open the catalog to page 9All Trox GmbH catalogs and technical brochures
-
Type QLV
18 Pages
-
Type QLE
14 Pages
-
Type QLF
16 Pages
-
Type ASW
10 Pages
-
Type AGW
10 Pages
-
Type DGW
10 Pages
-
Type TRS-R
15 Pages
-
Type TR
16 Pages
-
Type X-GRILLE Basic
18 Pages
-
Type AWT
15 Pages
-
Type TRS-K
15 Pages
-
Type X-GRILLE Cover
18 Pages
-
X-GRILLE modular
28 Pages
-
LVS
9 Pages
-
AK-Uni
15 Pages
-
Type DLQ-AK
15 Pages
-
Type VD
17 Pages
-
Type RFD-SIRIUS
19 Pages
-
Type PCD
12 Pages
-
FD
20 Pages
-
TDF-SILENTAIR
20 Pages
-
RFD
29 Pages
-
AIRNAMIC
19 Pages
-
AKR