Type TR
1 /16Pages

Type TR

Type TR
1 /16Pages

Catalog excerpts

Type TR-1

Ventilation grilles for instal lation into walls, sills or rec tangular ducts Type TR Ventilation grilles, made of sheet steel, with indivi dually adjustable, horizontal blades Ventilation grille with droplet shaped blades ■■ Nominal sizes 225 × 125 – 1225 × 525 mm ■■ Volume flow rate range 23 – 2000 l/s or 83 – 7200 m³/h ■■ Grille face made of sheet steel, powder-coated ■■ Front border with countersunk holes, 27 mm wide Optional equipment and accessories ■■ Grille face in RAL CLASSIC colours ■■ Grille face made of galvanised sheet steel, without powder coating ■■ Installation subframe ■■ Installation subframe for fitting filter media ■■ Attachments for volume flow rate balancing and air direction con

 Open the catalog to page 1
Type TR-2

Ventilation grilles for installation into walls, sills or rectangular ducts General information Page General information Function Technical data Quick sizing Specification text Order code Dimensions and weight Product details Installation examples Installation details Commissioning Basic information and nomenclature Application – Ventilation grille of Type TR as supply air or extract air variant for comfort zones and industrial zones – Directed supply air discharge for mixed flow ventilation – Blades are adjustable to meet different local requirements – For variable and constant volume flows...

 Open the catalog to page 2
Type TR-3

Ventilation grilles for installation into walls, sills or rectangular ducts Functional description Ventilation grilles are air terminal devices for the supply air and extract air of ventilation and air conditioning systems. They direct the supply air into the room. Ventilation grilles with adjustable blades allow for adapting the discharge direction to the local conditions. The result is a mixed flow ventilation in comfort zones and industrial zones, with good overall room ventilation. Induction slows the airflow down, i.e. the airflow velocity decreases as the distance from the grille increases....

 Open the catalog to page 3
Type TR-4

Ventilation grilles for installation into walls, sills or rectangular ducts Air pattern with ceiling effect, sectional view Air pattern without ceiling effect, sectional view Distance from ceiling ≤ 0.3 m Air pattern with ceiling effect, top view Air pattern without ceiling effect, top view Air pattern with ceiling effect, group of grilles, top view Distance between single grilles ≥ 0.15 × lS Distance from ceiling ≤ 0.8 m Air pattern without ceiling effect, group of grilles, top view Distance between single grilles ≥ 0

 Open the catalog to page 4
Type TR-5

Ventilation grilles for installation into walls, sills or rectangular ducts Air pattern, group of grilles, top view b < 0.1 × lS Several single grilles arranged in a row and with not much distance between them have the same effect as a continuous horizontal run.

 Open the catalog to page 5
Type TR-6

Ventilation grilles for installation into walls, sills or rectangular ducts Technical data Nominal sizes Minimum volume flow rate Maximum volume flow rate, with LWA max. 40 dB(A) without attachments Supply air to room air temperature difference Volume flow rates apply to supply air Geometric free area H mm Effective air discharge area (supply air) H mm Effective area of extract air grille H mm

 Open the catalog to page 6
Type TR-7

Ventilation grilles for installation into walls, sills or rectangular ducts Quick sizing × LWA = 40 dB(A) with unrestricted airflow+ LWA = 40 dB(A) with airflow restricted

 Open the catalog to page 7
Type TR-8

Ventilation grilles for installation into walls, sills or rectangular ducts Specification text This specification text describes the general properties of the product. Texts for variants can be generated with our Easy Product Finder design programme. Ventilation grilles, rectangular, made of sheet steel, for supply and extract air. Aesthetic sloped border with chamfered inside edge Preferably for wall and sill installation but also suitable for rectangular ducts. Ready-to-install component which consists of a border and individually adjustable, horizontal blades. Concealed screw fixing or countersunk...

 Open the catalog to page 8
Type TR-9

Ventilation grilles for installation into walls, sills or rectangular ducts Order code  Type TR Single grille  Attachments A Without (grille face only) AG Damper unit, opposed action blades AS Hit and miss damper D Air direction control, blades installed at 90° to the front blades, independently adjustable DG D combined with AG  Nominal size [mm] L × H  Installation subframe No entry: none A1 With Order example: TR-DG/825×225/A1/C11  Fixing No entry: countersunk holes C11 With concealed screw fixing  Exposed surface No entry: powder-coated RAL 9010, pure white P1 Powder-coated, specify...

 Open the catalog to page 9
Type TR-10

Ventilation grilles for installation into walls, sills or rectangular ducts Order code  Type E-EF Replacement filter medium  Nominal size [mm] L × H

 Open the catalog to page 10
Type TR-11

Ventilation grilles for installation into walls, sills or rectangular ducts The weight table shows the available nominal sizes TR, 27 mm wide front border L Nominal length Vertical centre mullion if L > 625 mm Weights apply to ventilation grilles without attachments

 Open the catalog to page 11
Type TR-12

Ventilation grilles for installation into walls, sills or rectangular ducts Product details

 Open the catalog to page 12
Type TR-13

Ventilation grilles for installation into walls, sills or rectangular ducts Installation examples Wall installation Nominal length over 625 mm: with vertical centre mullion

 Open the catalog to page 13
Type TR-14

Ventilation grilles for installation into walls, sills or rectangular ducts Installation details Installation and commissioning – Installation preferably in walls, sills and rectangular ducts – Installation with installation subframe is recommended – If no installation subframe is used, the border should be fixed with screws These are only schematic diagrams to illustrate installation details. Ventilation grille with concealed screw fixing ① Installation subframe ② Concealed screw fixing ③ Ventilation grille Ventilation grille with spring clip fixing ① Installation subframe ② Spring clip ③ Ventilat...

 Open the catalog to page 14
Type TR-15

Ventilation grilles for installation into walls, sills or rectangular ducts Volume flow rate balancing When several ventilation grilles are installed on the same duct, it may be necessary to balance the volume flow rates. – AG: Damper unit with opposed action blades, adjustable, secured with a locking screw – AS: Damper unit with hit and miss damper, adjustable, secured with a locking screw Air pattern – Adjustable blades: Set the air control blades individually or together and depending on the local conditions – D, DG: Air control blades, fitted at 90° to the front blades, can be adapted to...

 Open the catalog to page 15

All Trox GmbH catalogs and technical brochures

  1. Type QLV

    18  Pages

  2. Type QLE

    14  Pages

  3. Type QLF

    16  Pages

  4. Type ASW

    10  Pages

  5. Type AGW

    10  Pages

  6. Type DGW

    10  Pages

  7. Type TRS-R

    15  Pages

  8. Type AWT

    15  Pages

  9. Type TRS-K

    15  Pages

  10. Z-LVS

    9  Pages

  11. LVS

    9  Pages

  12. AK-Uni

    15  Pages

  13. Type DLQ-AK

    15  Pages

  14. Type VD

    17  Pages

  15. Type RFD-SIRIUS

    19  Pages

  16. Type PCD

    12  Pages

  17. FD

    20  Pages

  18. TDF-SILENTAIR

    20  Pages

  19. RFD

    29  Pages

  20. AIRNAMIC

    19  Pages

  21. AKR

    9  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.