Type AGW
10Pages

{{requestButtons}}

Catalog excerpts

Type AGW - 1

Volume flow rate balancing Type AGW Damper units, made of dip coated sheet steel, for installation into rectangular ducts Damper units with opposed action blades ■■ Nominal sizes 225 × 75 – 1225 × 525 mm ■■ Perimeter angle section frame

Open the catalog to page 1
Type AGW - 2

Volume flow rate balancing General information Page General information Function Technical data Specification text Order code Dimensions and weight Installation details Commissioning Basic information and nomenclature Application – Type AGW damper units for supply air and extract air – Adjustable blades for volume flow rate balancing – For installation into rectangular ducts Nominal sizes Parts and characteristics – Angle section frame – Front border – Adjustable transverse blades, opposed action Construction features – Centrally supported blades – Angle section frame without fixing holes...

Open the catalog to page 2
Type AGW - 3

Volume flow rate balancing ① Blade for flow adjustment

Open the catalog to page 3
Type AGW - 4

Volume flow rate balancing Technical data Nominal sizes

Open the catalog to page 4
Type AGW - 5

Volume flow rate balancing Specification text This specification text describes the general properties of the product. Texts for variants can be generated with our Easy Product Finder design programme. Damper units, rectangular, made of sheet steel, for supply and extract air. Installation preferably in rectangular ducts. Ready-to-install component which consists of an angle section frame and transverse opposed action blades for flow adjustment. Materials and surfaces – Angle section frame and blades made of sheet steel – Angle section frame and blades dip coated RAL 9005, jet black...

Open the catalog to page 5
Type AGW - 6

Volume flow rate balancing Order code  Type AGW Damper unit Order example: AGW/625×225 Nominal size

Open the catalog to page 6
Type AGW - 7

Volume flow rate balancing The weight table shows the available nominal sizes

Open the catalog to page 7
Type AGW - 8

Volume flow rate balancing Installation details Installation and commissioning – Installation preferably in rectangular ducts – Fix the angle section frame with screws or rivets

Open the catalog to page 8
Type AGW - 9

Volume flow rate balancing Volume flow rate balancing When several ventilation grilles are installed on the same duct, it may be necessary to balance the volume flow rates. – Damper unit with opposed action blades, adjustable, secured with a locking screw Volume flow rate balancing -*G X

Open the catalog to page 9
Type AGW - 10

Volume flow rate balancing Basic information and nomenclature Principal dimensions Nominal height of the ventilation grille L [mm] Nominal length of the ventilation grille Nomenclature LWA [dB(A)] Sound power level of the air-regenerated noise  [m³/h] and [l/s] Volume flow rate Δpt [Pa] Total differential pressure lS [m] Distance from single grille or horizontal run section (throw distance)

Open the catalog to page 10

All Trox GmbH catalogs and technical brochures

  1. Type QLV

    18 Pages

  2. Type QLE

    14 Pages

  3. Type QLF

    16 Pages

  4. Type ASW

    10 Pages

  5. Type DGW

    10 Pages

  6. Type TRS-R

    15 Pages

  7. Type TR

    16 Pages

  8. Type AWT

    15 Pages

  9. Type TRS-K

    15 Pages

  10. Z-LVS

    9 Pages

  11. LVS

    9 Pages

  12. AK-Uni

    15 Pages

  13. Type DLQ-AK

    15 Pages

  14. Type VD

    17 Pages

  15. Type PCD

    12 Pages

  16. FD

    20 Pages

  17. TDF-SILENTAIR

    20 Pages

  18. RFD

    29 Pages

  19. AIRNAMIC

    19 Pages

  20. AKR

    9 Pages