1. Catalogs
  2. Trimod'Besta
  3. Operating instructions – types I…5, IE9…5

Operating instructions – types I…5, IE9…5

Operating instructions – types I…5, IE9…5
1 / 59 PagesView full catalog

Operating instructions – types I…5, IE9…5

Product catalog summary
Operating Instructions Overview:
The document provides comprehensive operating instructions for the Trimod Besta Level Switch, designed for use in potentially explosive atmospheres. It includes certification schemes such as ATEX, UKEX, and IECEx.
Main Sections:
  • Used Symbols and Signs: Clarifies symbols used for safety and clarity.
  • Safety Instructions: Guidelines for safe operation and handling.
  • Intended Use: Appropriate applications and environments for the switch.
  • Conformity of Standards: Compliance with international standards and certifications.
  • Technical Data: Specifications including operational parameters and environmental conditions.
  • Installation and Initial Start-up: Step-by-step installation and commissioning instructions.
  • Maintenance: Routine maintenance guidelines for longevity and reliability.
  • Malfunctioning and Troubleshooting: Solutions for common operational issues.
  • Replacement of the Switch Module: Instructions for component replacement.
  • Fire Protection: Precautions to prevent fire hazards.
  • Disposal: Methods for environmentally compliant disposal.
  • Storage & Transport: Recommendations for safe storage and transportation.
  • Certification Appendices: Includes various certification documents and temperature diagrams.
Key Information:
The document emphasizes adherence to safety instructions and intended use to prevent accidents in explosive environments. Compliance with international standards is crucial for safe operation.
Maintenance:
Annual inspection and cleaning are required. Key steps include disconnecting power, ensuring atmospheric pressure, inspecting for damage, and using original spare parts for replacements.
Troubleshooting:
Common issues include lack of power, float obstruction, or damage. Solutions involve checking power supply, cleaning, and replacing components.
Switch Module Replacement:
Defective modules must be replaced with factory-tested units, requiring complete type numbers for ordering.
Fire Protection and Disposal:
Switches must be protected from external fires and disposed of according to regulations, free from hazardous materials like asbestos.
Storage and Transport:
Store in original packaging, protected from damage and environmental factors, within specified temperature ranges.
Safety Instructions:
Installation by qualified personnel is required, following explosion-proof standards and regulations.
Intended Use:
Designed for monitoring liquids in various industries, adhering to explosion protection standards.
Conformity and Standards:
Complies with ATEX, UKEX, and IECEx standards, certified for safety integrity levels.
Technical Data:
Includes explosion protection markings, electrical connection guidelines, and recommended evaluation electronics.
Specifications:
Outlines different types of level switches, categorized by design and application, with specific limits for proximity switch types and temperature conditions.
Installation and Initial Start-up:
Emphasizes correct operating position, free float movement, and avoiding turbulence, with detailed flange connection instructions.
Maintenance:
Regular maintenance includes disconnecting power, venting vessels, checking for damage, and using original spare parts.
Malfunctioning and Troubleshooting:
Lists common malfunctions and remedies, such as checking voltage and ensuring float movement.
Replacement of the Switch Module:
Defective modules must be replaced with new, tested units, with proper documentation for explosive atmospheres.
Fire Protection and Disposal:
Protection against external fires and compliance with disposal regulations are required.
Storage and Transport:
Store in a dry, clean place, protected from damage, within specified temperature ranges.
Safety and Compliance:
Includes safety instructions for handling electrical connections and adhering to explosion-proof standards, with compliance to international standards.
Technical Specifications:
Outlines explosion protection data and certification details, with SIL levels for proximity detectors.
Electrical Connection:
Adheres to safety regulations for explosion-proof devices, with specific cable requirements.
Amplifier-Separator Selection:
Guidelines for ensuring output values remain below certified limits.
Implementation Principles:
Describes operational principles for various detector types.
Installation and Commissioning:
Requires attention to service position and free float movement, with specific flange and electrical connection instructions.
Maintenance:
Regular verification and cleaning are recommended.
Troubleshooting:
Provides a guide for common issues and remedies.
Replacement of Control Module:
Emphasizes the use of original parts for replacements.
See more

Catalog excerpts

Operating instructions – types I…5, IE9…5-1

Betriebsanleitung Operating instructions Mode d’emploi Instrucciones de servicio Betriebsanleitung Trimod Besta Füllstandschalter Typ I…8, IE9…8 Für den Einsatz in explosionsgefährdeten Bereichen Typ I…7, IE9…7 Typ I…5, IE9…5 Operating instructions Trimod Besta Level Switch for use in potentially explosive atmospheres Instrucciones de servicio Interruptor de nivel Trimod Besta para uso en atmósferas potencialmente explosivas 2014/34/EU (ATEX) UK SI 2016 No. 1107 (UKEX) IECEx scheme (IECEx) Type I…8, IE9…8 2014/34/EU (ATEX) Type I…7, IE9…7 UK SI 2016 No. 1107 (UKEX) Type I…5, IE9…5 acc. to IECEx scheme (IECEx) Mode d’emploi Contrôleur de niveau Trimod Besta Type I…8, IE9…8 pour utilisation en zones à risque d'explosion Type I…7, IE9…7 UK SI 2016 No. 1107 (UKEX) Type I…5, IE9…5 IECEx scheme (IECEx) Tipo I…8, IE9…8 2014/34/UE (ATEX) Tipo I…7, IE9…7 UK SI 2016 No. 1107 (UKEX) Tipo I…5, IE9…5 IECEx scheme (IECEx) Technische Änderungen vorbehalten / Subject to technical modification / Sous réserve de modifications techniques / Se reserva el derecho de realizar modificacio

 Open the catalog to page 1
Operating instructions – types I…5, IE9…5-3

Level measurement A brand of Bachofen AG www.trimodbesta.com Betriebsanleitung Operating instructions Mode d’emploi Instrucciones de servicio

 Open the catalog to page 3
Operating instructions – types I…5, IE9…5-4

Level measurement A brand of Bachofen AG www.trimodbesta.com Betriebsanleitung Operating instructions Mode d’emploi Instrucciones de servicio 7, IE9...7 UK SI 2016 No. 1107 (UKEX) 5, IE9...5 IECEx scheme (IECEx) Trimod Besta Fullstandschalter - Typ I Trimod Besta Fullstandschalter - Typ I Trimod Besta Fullstandschalter - Typ I 2. Sicherheitshinweise 1” Vordem Einbau muss die Betriebsanleitung gelesen und verstanden werden. Bei Unklarheiten kon-taktieren Sie die Bachofen AG. Der elektrische Anschluss darf nur durch qualifiziertes und vom Betreiber autorisiertes Personal vor-genommen werden. Alle...

 Open the catalog to page 4
Operating instructions – types I…5, IE9…5-5

Level measurement A brand of Bachofen AG www.trimodbesta.com Betriebsanleitung Operating instructions Mode d’emploi Instrucciones de servicio |SIL Wenn ein Trimod Besta Fullstandschalter in einer sicherheitsrelevanten Anwendung nach IEC 61508 und IEC 61511 eingesetzt wird, muss der Einbau und die Inbetriebnahme gemass dem Safety Manual erfolgen. Das Safety Manual fuhrt die Einschrankungen und Grenzwerte der IEC 61508-Zertifizierung fur Trimod Besta Fullstandschalter auf. Es kann unter http://www.trimodbesta.com/downloads/Operating Instruction/ heruntergeladen werden. Die Trimod Besta Fullstandschalter...

 Open the catalog to page 5
Operating instructions – types I…5, IE9…5-6

Level measurement A brand of Bachofen AG www.trimodbesta.com Betriebsanleitung Operating instructions Mode d’emploi Instrucciones de servicio Die Auswahl des Trennschaltverstarkers beeinflusst indirekt die Maximaltemperaturen des Initiators. Daher mussen die Werte Uo, Io und Po alle unterhalb der in der jeweiligen Konformitatsbescheinigung angegebenen Grenzwerte Ui, Ii und Pi sein. Es gilt also: Uo (Trennschaltverstarker) < Ui (Initiator) Entsprechend der Wahl eines Trennschaltverstarkers durch den Betreiber ergibt sich via die beschei-nigten Hochstwerte und der vom Medium abhangigen Temperaturklasse...

 Open the catalog to page 6
Operating instructions – types I…5, IE9…5-7

Level measurement A brand of Bachofen AG www.trimodbesta.com Betriebsanleitung Operating instructions Mode d’emploi Instrucciones de servicio

 Open the catalog to page 7
Operating instructions – types I…5, IE9…5-8

Level measurement A brand of Bachofen AG www.trimodbesta.com Betriebsanleitung Operating instructions Mode d’emploi Instrucciones de servicio Fullstandschalter mit Warmetauscher fur sehr hohe Betriebstemperaturen (Flachdichtungen IP65) Grenzwerte Umgebungs- Induktiver Nahe- temperatur Betriebs- temperatur Die Kombinationen der Maximalwerte sind zu vermeiden! Grenzwertkombinationen gemass Temperaturdiagramm Grenzwerte Umgebungs- Induktiver Nahe- temperatur Betriebs- temperatur Die Kombinationen der Maximalwerte sind zu vermeiden! Grenzwertkombinationen gemass Temperaturdiagramm Fullstandschalter...

 Open the catalog to page 8
Operating instructions – types I…5, IE9…5-9

Level measurement A brand of Bachofen AG www.trimodbesta.com Betriebsanleitung Operating instructions Mode d’emploi Instrucciones de servicio Fur seitlichen Einbau Pfeil "OBEN" auf Typenschild achten. Der Schwimmer muss sich frei uber den ganzen Weg bewegen konnen und darf nicht durch Tank-wande oder Tankeinbauten behindert werden. Einbaulagen, wo Turbulenzen sind, storen die Funktion und sollten unbedingt vermieden werden. Prozess-Anschlussflansch - Industriereihe Fur Schalter der Industriereihe mit Flanschen nach EN/DIN, ANSI usw. mussen die Dichtungen 1 und die Verbindungsbolzen 1 der entsprechenden...

 Open the catalog to page 9
Operating instructions – types I…5, IE9…5-10

Level measurement A brand of Bachofen AG www.trimodbesta.com Betriebsanleitung Operating instructions Mode d’emploi Instrucciones de servicio 7. Wartung Trimod Besta Fullstandschalter sind periodisch (min. 1x jahrlich) zu prufen und zu reinigen. yj\ 1. Vor dem Offnen des Gehauses die Speisespannung unterbrechen, Stromschlage konnen le-bensbedrohend sein. 2. Prozessbehalter/Schwimmerkammern mtissen vor Durchftihrung von Arbeiten auf atmosphari-schen Druck gebracht und entsprechend beluftet werden. Falls notig, Fullstand absenken. 1st der Schalter in einer Kammer montiert, entsprechende Absperrventile...

 Open the catalog to page 10
Operating instructions – types I…5, IE9…5-11

Betriebsanleitung Operating instructions Mode d’emploi Instrucciones de servicio dem Typenschild nur die Schaltmodulnummer eingeprägt. Diese ist für eine spätere Rückverfolgbarkeit des Schaltertyps ungenügend und muss daher unbedingt vom Betreiber ergänzt werden. Beispiel: Komplette Typennummer des Schalters I8 01 04 Nur Ersatz Schaltmodul I8 Typennummer komplettieren mit 01 04 I8 01 04 Das Vorgehen für das Ersetzen des Schaltmoduls wird in der ergänzenden Montageanleitung LTI004X «Schaltmodul Austausch» entnommen. Dieses Dokument wird mit dem Ersatz-Schaltmodul geliefert. Der korrekte Einbau...

 Open the catalog to page 11
Operating instructions – types I…5, IE9…5-12

Level measurement A brand of Bachofen AG www.trimodbesta.com Betriebsanleitung Operating instructions Mode d’emploi Instrucciones de servicio Trimod Besta Level Switch - type I_8, IE9...8 Trimod Besta Level Switch - type I...7, IE9...7 Trimod Besta Level Switch - type I...5, IE9...5 UK SI 2016 No. 1107 (UKEX) IECEx scheme (IECEx) 1. Used symbols and signs The operating manual must be read and understood before installation. If you are uncertain on any point, please contact Bachofen AG, Switzerland. The electrical connection may only be carried out by qualified personnel who have been authorised...

 Open the catalog to page 12
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.