800 Infinitron® ESVM
2Pages

{{requestButtons}}

Catalog excerpts

800 Infinitron® ESVM - 1

The ±100 V Trek Model 800 Infinitron® Voltmeter may be used in either contacting or non-contacting mode to acquire precision surface voltage measurements. It is especially beneficial when used with applications that demand infinitely high loading impedance levels far beyond the reach of currently available high impedance voltmeter instruments. The Model 800 comes with a guarantee of virtually no modification of the object being measured. This allows the instrument to indicate, with high precision, the voltage level of both conductive and insulative objects and surfaces. Key Specifications • Measurement Range: 0 to ±100 V DC or peak AC • Measurement Accuracy: Better than ±0.1% of full scale (voltage monitor output) • Speed of Response: Less than 3.5 ms for a 100 V input step • Input Characteristics Resistance: Greater than 1 x 1016 W Capacitance: Less than 1 x 10-15 F Typical Applications Include • Accurate reading of electrostatic voltage levels associated with ESD sensitive components, circuits and surfaces Features and Benefits • Two voltage monitor outputs scale factors at 20:1 and 1:1 • Probe electrode may be easily replaced with other sensor tips • Monitor provides a low voltage replica of the measured electrostatic potential for monitoring purposes or for use as a feedback signal in a closed loop system • Easy-to-read LED display • CE compliant • Designed to be operated on a bench top Available Probes • Model 800P Probe - Sensor 1.27 mm gold plated rounded tip electrode. The sensors may be easily replaced, dependent on the measurement requirements - Orientation Pencil probe structure with end contact sensor. - Probe Dimensions 192.2 mm L x 33.9 mm Diameter (7.57” L x 1.34” Diameter) - Probe Cable Length 3 m ±76 mm (10 ft ±3 in.) TREK, INC. • 190 Walnut Street • Lockport, NY 14094 • USA • 800-FOR TREK 716-438-7555 • 716-201-1804 (fax) • www.trekinc.com •

Open the catalog to page 1
800 Infinitron® ESVM - 2

Performance Measurement Range Measurement Accuracy Voltage Monitor Output Voltage Display Speed of Response (10% to 90%) Large Signal Bandwidth (-3 db) Input Resistance Input Capacitance Voltage Monitor Output Ratio Output Voltage Output Noise Output Impedance Features 0 to ±100 V DC or peak AC Better than ±0.1% of full scale Better than ±0.1% of reading, ±1 digit (referred to measured input) Less than 3.5 ms for 100 V step DC to greater than 100 Hz for 200 V pp Greater than 1 X 1016 W Less than 1 X 10-15 F Two BNC outputs provide buffered low-voltage replica of the measured voltage 20:1 of...

Open the catalog to page 2

All TREK catalogs and technical brochures

  1. PD04002A

    2 Pages

  2. 158A

    2 Pages

  3. 157

    2 Pages

  4. 156A

    2 Pages