605A High-Voltage Reference Supply
2Pages

{{requestButtons}}

Catalog excerpts

605A High-Voltage Reference Supply - 1

The Trek Model 605A is a high-voltage reference supply designed to provide precise control of output voltages in the range of 0 to +1 kV DC or 0 to -1 kV DC with an output current range of 0 to ±1 mA DC. • Line and Load Regulation Better than 0.002% • Automatic current limit feature to protect the instrument from output short circuits or overloads • Remote high voltage on/off feature ideal for use with automated or computer-controlled systems Model 605AHigh-Voltage Reference Supply • Output Voltage Range Fixed Mode +1 kV or -1 kV Variable Mode 0 to +1 kV or 0 to -1 kV • Output Current Range 0 to ±1 mA • Output Accuracy Better than 0.1% of Full Scale The Model 605A provides two modes of operation, a fixed mode providing a constant +1 kV or -1 kV output, and a variable mode providing variable control of the output voltage with a one (1) volt resolution over a range of 0 to ±1 kV. The Model 605A features an all-solid-state design for accurate, low-noise operation and is protected against over-current conditions that may be generated by output short circuits to ground. A Digital Enable feature provides a connection for a remote device to turn on and off the high voltage of the instrument. This makes the 605A suitable for automated or computer-controlled systems. The 605A is designed to be operated on a bench top. Please contact TREK, INC. for further information about this product and its various applications. We would like to talk with you about your particular needs and determine how this product or other Trek products can meet your specific requirements.

Open the catalog to page 1
605A High-Voltage Reference Supply - 2

All specifications are with no load unless otherwise noted. Output Output Voltage Range Fixed Mode +1 kV or -1 kV. Variable Mode Adjustable from 0 to +1 kV DC or 0 to -1 kV DC. Output Voltage Resolution (Variable Mode) 1 V. Output Current Range 0 to ±1 mA DC. Performance Output Voltage Accuracy Fixed Mode Better than 0.1% of full scale. Variable Mode Better than 0.1% of full scale. Zero Offset Voltage Less than 500 mV. Regulation Line Better than 0.002% for a line change from 90 to 110 V AC, 104 to 126 V AC, or 207 to 250 V AC. Load Better than 0.002% for a load change from 0 to 1...

Open the catalog to page 2

All TREK catalogs and technical brochures

  1. PD04002A

    2 Pages

  2. 158A

    2 Pages

  3. 157

    2 Pages

  4. 156A

    2 Pages