SAFETY DATA SHEET Tough GardTM 1. IDENFICATION OF THE SUBSTANCE/MIXTURE AND THE COMPANY/UNDERTAKING 1.1 Product Identifier: Trade name: TOUGH GARD™ Anti-Spatter Liquid Product Number: TG101-01, TG101-05, TG101-14S, TG101-32SP, TG101-55. 1.2 Relevant Identified Users of the Substance or Mixture and Uses Advised Against Product use: Protect welding torch components from excessive spatter accumulation. 1.3 Details of the Supplier of the Safety Data Sheet: Manufacturer: Tregaskiss, 2570 North Talbot Road, Windsor, Ontario, Canada N0R 1L0, Information Phone: 1-855-644-9353, Fax: 1-877-737-2111, email: techsupport@tregaskiss.com 1.4 Emergency Phone Number: Spill information: 1-519-737-3000 (8:00 a.m. to 5:00 p.m., time zone: -5) 1.5 SDS Date of Preparation: July 31, 2015 2. HAZARDS IDENTIFICATION 2.1 Classification of the Substance of Mixture CLP/GHS Classification (1272/2008): Not classified as hazardous EU Classification (67/548/EEC): Not classified as dangerous 2.2 Label elements: None required 2.3 Other hazardous: No 3. COMPOSITION/INFORMATION ON INGREDIENTS 3.1 Substances Chemical Name Polymeric Glycol Not classified as dangerous Not classified as dangerous GHS Classification Regulation (EC) No 1272/2008 Not hazardous See Section 16 for further information on EU and GHS Classification 4: FIRST AID MEASURES 4.1 Description of First Aid Measures Eye: Flush with running water for at least 15 minutes. Get medical attention if irritation develops. Skin: No first aid should be required. Wash with running water and soap. Inhalation: No first aid should be needed. Remove to fresh air. Assist in breathing if necessary, and get medical attention. Ingestion: Rinse mouth with water. Seek medical attention. 4.2 Most important Symptoms and Effects, Both Acute and Delayed: May cause slight eye irritation with redness and tearing. 4.3 Indication of Any Immediate Medical Attention and Special treatment Needed: None required.
Open the catalog to page 15. FIRE-FIGHTING MEASURES 5.1 Extinguishing Media: Use any media that is suitable for the surrounding fire. 5.2 Special Hazards Arising from the Substance or Mixture: Unusual Fire and Explosion Hazards: None, this product is not combustible. Hazard Decomposition Products: Combustion of the residue after the water has evaporated will release oxides of carbon. 5.3 Advice for Fire-Fighters: Firefighters should always wear self-contained breathing apparatus and full protective clothing for fires involving chemicals or in confined spaces. Cool fire exposed containers with water. 6. ACCIDENTAL...
Open the catalog to page 29. PHYSICAL AND CHEMICAL PROPERTIES 9.1 Information on Basic Physical and Chemical Properties: Appearance: Green translucent liquid Vapor density: Same as water Odor: Odorless Specific Gravity: 1.04 (Water = 1.00). Odor Threshold: No data available Solubility in water by wt: 100 % water-soluble pH: 5 – 7 Octanol/water partition coefficient: Not available Auto-ignition Temperature: None Boiling point @ 760 mmHg: 100 C. Decomposition Temperature: None Freezing Point: - 2 C Flash point: Non-flammable Viscosity: 1.02 centipoises at 25 C Evaporation Rate: < 0.01 (n-Butyl acetate = 1.00)...
Open the catalog to page 312. ECOLOGICAL INFORMATION 12.1 Toxicity: Practically non-toxic to aquatic organisms. Polymeric glycol: LC50 fathead minnow 87,209 mg/L/96 hr; LC50 daphnia magna 53,484 mg/L/48 hr. 12.2 Persistence and Degradability: Polymeric glycol is expected to readily biodegrade. BOD 20 40.2-70%. 12.3 Bioaccumulative Potential: Not expected to bioacumulate. 12.4 Mobility in Soil: No data available. 12.5 Results of PBT and vPvB Assessment: Not required. 12.6 Other Adverse Effects: None known 13. DISPOSAL INFORMATION Dispose in accordance with federal, state and local environmental control regulations....
Open the catalog to page 4U.S. Regulations: OSHA Hazard Classification: Not Hazardous CERCLA: This product is not subject to CERCLA reporting requirements, however, many states have more stringent release reporting requirements. Report spills required under federal, state and local regulations. EPA SARA 302: This product does not contain chemicals regulated under SARA Section 302. EPA SARA 311 Hazard Classification: Not Hazardous EPA SARA 313: This product contains the following chemicals that are regulated under SARA Title III, section 313: None California Proposition 65: This product contains the following...
Open the catalog to page 5All Tregaskiss catalogs and technical brochures
-
TREGASKISS™ POWER PINS
3 Pages
-
TOUGH GUN™ TT3 Reamer
8 Pages
-
Tregaskiss™
14 Pages
-
AUTOMATION CATALOG
15 Pages
-
TOUGH GUN I.C.E
2 Pages
-
Tregaskiss Automation Catalog
13 Pages
-
Power Pins Spec Sheet
3 Pages
-
Control Plugs Spec Sheet
2 Pages