LRS-100 series

LRS-100 series

LRS-100 series

Product catalog summary

Overview

This document provides detailed technical specifications, safety standards, environmental conditions, protection features, and mechanical details for the 100W Single Output Switching Power Supply LRS-100 series by Mean Well.

Specifications

  • Models and Output Voltages: Available in 3.3V, 5V, 12V, 15V, 24V, 36V, and 48V variants.
  • Rated Current: Ranges from 2.3A (48V model) up to 20A (3.3V model).
  • Rated Power: Approximately 66W to 110.4W depending on model.
  • Output Voltage Adjustment Range: Each model has a specified adjustable voltage range (e.g., 3.8~4.45V for 5V model).
  • Ripple & Noise: Maximum ripple ranges from 100mVp-p to 200mVp-p depending on output voltage.
  • Voltage Tolerance: ±1.0% typical, with line regulation ±0.5% and load regulation ±0.5% to ±2.0% depending on model.
  • Input Voltage Range: 85~264VAC or 120~373VDC withstanding 300VAC surge for 5 seconds.
  • Frequency Range: 47~63Hz.
  • Efficiency: Typical efficiency ranges from 84.5% to 91% depending on model.
  • Inrush Current: Cold start 50A at 230VAC.
  • Leakage Current: Less than 0.75mA at 240VAC.
  • Hold-up Time: Typically 55ms at 230VAC full load.

Protection Features

  • Overload Protection (O.L.P.): Hiccup mode with automatic recovery after fault removal.
  • Overvoltage Protection (O.V.P.): Shut down output voltage, requires re-power on to recover.

Safety and Compliance

  • Certified to UL 62368-1, TUV EN62368-1, EN60335-1, EN61558-1, BSMI CNS14336-1, CCC GB4943, and other regional standards.
  • EMC compliance includes EN55032 (CISPR32) Class B, EN55014, EN61000-3-2/-3, GB/T 9254, and others.
  • EMC Immunity tested to EN61000-4 series standards and heavy industry level criteria A.
  • Overvoltage category III compliant with EN61558, EN50178, EN60664-1, EN62477-1; suitable for altitudes up to 2000 meters.

Environmental Conditions

  • Operating temperature range: -30°C to +70°C (with derating).
  • Storage temperature: -40°C to +85°C.
  • Humidity: 20% to 90% RH non-condensing during operation; 10% to 95% RH non-condensing for storage.
  • Vibration resistance: 10~500Hz, 5G, 10 minutes per cycle along X, Y, Z axes.
  • MTBF: Minimum 720,600 hours at 25°C per MIL-HDBK-217F.

Mechanical and Installation Details

  • Dimensions: 129mm (L) x 97mm (W) x 30mm (H).
  • Weight: Approximately 0.34 kg.
  • Packing: 40 pieces per carton, total weight 14.6 kg, volume 0.92 cubic feet.
  • Terminal pin assignments clearly defined for DC output, AC input, and FG (frame ground).
  • Includes a derating curve for operation at different ambient temperatures and loads.
  • Block diagram provided showing internal circuit components such as EMI filter, rectifiers, power switching, control, and protection circuits.

Additional Notes

  • Setup and rise time: 500ms at 230VAC, 30ms at 115VAC at full load.
  • Recommended to refer to the official manual at http://www.meanwell.com/manual.html for detailed installation and usage instructions.
See more

Catalog excerpts

LRS-100 series-1

100W Single Output Switching Power Supply Bauar t gepruft Sicherheit egel ma ge od o s be wac g Universal AC input / Full range Withstand 300VAC surge input for 5 second Protections: Short circuit / Overload / Over voltage Cooling by free air convection Miniature size and 1U low profile Compliance to IEC/EN 60335-1(PD3) and IEC/EN61558-1, 2-16 for household appliances Operating altitude up to 5000 meters (Note.7) Withstand 5G vibration test LED indicator for power on No load power consumption<0.3W Over voltage category Ⅲ 100% full load burn-in test High operating temperature up to 70℃ High efficiency, long life and high reliability 3 years warranty Industrial automation machinery Industrial control system Mechanical and electrical equipment Electronic instruments, equipments or apparatus Household appliances ■ Model Encoding LRS - 100 - 3.3 Output voltage Rated wattage Series name

 Open the catalog to page 1
LRS-100 series-2

100W Single Output Switching Power Supply SPECIFICATION MODEL RATED CURRENT CURRENT RANGE RATED POWER SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE LEAKAGE CURRENT 10ms/115VAC at full load 120 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) 88% 110 ~ 150% rated output power OVER LOAD Protection type : Hiccup mode, recovers automatically after fault condition is removed OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover WORKING TEMP. -30 ~ +70℃ (Refer to "Derating Curve") WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85℃,...

 Open the catalog to page 2
LRS-100 series-3

100W Single Output Switching Power Supply Block Diagram RECTIFIERS & FILTER RECTIFIERS & FILTER POWER SWITCHING DETECTION CIRCUIT Derating Curve Static Characteristics

 Open the catalog to page 3
LRS-100 series-4

100W Single Output Switching Power Supply Mechanical Specification 4.5 Assignment DC OUTPUT -V DC OUTPUT +V Installation Manual Please refer to : http://www.meanwell.com/manual.html

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.