DDL Driver
5Pages

{{requestButtons}}

Catalog excerpts

DDL Driver - 1

DLA SERIES + ACCESSORIES LINEAR ACTUATORS

Open the catalog to page 1
DDL Driver - 2

ACTUATOR DATA Reduction ACTUATOR STROKE DATA Stroke version B (mm) Life time number single strokes Weight (g) Motor wiring ACTUATOR FEATURES AND STANDARD DATA STANDARD Type CUSTOMIZATION OPTIONS Electric linear actuator Motor type Voltage Screw type Noise level Life time Limit switches Direction movement Stroke tolerance Duty cycle Max. duty operational time Protection class Insulation class Max. motor winding temp. EMC Gear box 4 million mm total stroke Integrated non adjustable Stroke length By reversing voltage polarity 25% 1 min. max. thrust IP65 F 155 ºC EN55014 IEC61000 Metal spur...

Open the catalog to page 2
DDL Driver - 3

DLA series 50-300 mm 1200 N with potentiometer feedback 132 72 ACTUATOR DATA Reduction ACTUATOR STROKE DATA Stroke version B (mm) Resistance (Kohm) Feedback (ohm/mm) Life time number single strokes Weight (g) POTENTIOMETER FEATURES AND DATA ACTUATOR FEATURES AND STANDARD DATA STANDARD Type CUSTOMIZATION OPTIONS Noise level Life time Resistance tolerance ±0.25% 3+2 leads flying wire 900 mm 4 million mm total stroke Limit switches Wire wound 0.3 - 9.7 Kohm Cable Screw type Type Resistance Electric linear actuator Motor type Voltage Direction movement Stroke tolerance Duty cycle Max. duty...

Open the catalog to page 3
DDL Driver - 4

DLA series 50-300 mm 1200 N with hall sensor feedback 20 ACTUATOR STROKE DATA Stroke version B (mm) Life time number single strokes Weight (g) ACTUATOR DATA Reduction HALL SENSOR FEATURES AND DATA 5 Number of encoder channels Output saturnation voltage, Vce(sat) Output leakage current, Icex Output rise and fall time, tr/tf Hall sensor channel counts per mm ACTUATOR FEATURES AND STANDARD DATA STANDARD Type CUSTOMIZATION OPTIONS Electric linear actuator Hall sensor output circut Motor type Voltage Screw type Noise level Open collector output Vcc - Yellow Life time 4 million mm total stroke...

Open the catalog to page 4
DDL Driver - 5

DLA series control system CONTROL SYSTEM DATA 110/60Hz Output current limit (A) Weight HDL hand control (g) CONTROL SYSTEM FEATURES AND DATA STANDARD Type CUSTOMIZATION OPTIONS AC/DC transformer Battery backup Integrated voltage polarity switch Current limit Actuator connector Hand control connector Transmotec www.transmotec.com © Copyright Transmotec Page 5