TRANSMILLE 3010A PRECISION MULTIPRODUCT CALIBRATOR
24Pages

{{requestButtons}}

Catalog excerpts

TRANSMILLE 3010A PRECISION MULTIPRODUCT CALIBRATOR - 1

OUTPUT CONTROL LiliUfr LlliLiU high current mjxiuarv terming

Open the catalog to page 1
TRANSMILLE 3010A PRECISION MULTIPRODUCT CALIBRATOR - 2

3010A EXTENDED SPECIFICATIONS General Specifications TRANSMILLE LTD Due to continuous development specifications may be subject to change. 3010A Extended Specifications General Specifications : V1.81 www.T l"ansmille.com

Open the catalog to page 2
TRANSMILLE 3010A PRECISION MULTIPRODUCT CALIBRATOR - 3

1 year Total Accuracy Specifications at Tcal ±5°C & Range Parameters Range Stability (Accuracy relative to calibration Standards) Range Notes Note 1: Allowance must be made for output resistance when driving Into a load. Note 2: Limited by 50 Ohm output impedance. Note 3 : Internally adjustable from 2mA to 30mA - Factory set to 20mA as standard. For safety the trip is controlled by a fail-safe circuit independant of the processor which shuts the high voltage output off in the event of an overload. Note 4: Typical RMS noise figures at 50% of full scale, bandwidth 1Hz to 10Hz. High Voltage...

Open the catalog to page 3
TRANSMILLE 3010A PRECISION MULTIPRODUCT CALIBRATOR - 4

1 year Total Accuracy Specifications at TCal ±5°C & Range Parameters Range Stability (Accuracy relative to calibration Standards) Range Notes Note 1 : Typical RMS noise figures at 50% of full scale. Note 2 : Power & temperature sensor on 30A range - microprocessor monitors & protects from overheating. Higher resistance loads allow a longer ON period. See graphs 1 and 2 for details. Note 3 : Specifications apply to loads of less than 10% of the maximum burden voltage. Note 4: Zero or floor allowance. Specifications apply at TCal ± 5°C Outside this range an allowance of 0.18 x 1 Year Spec....

Open the catalog to page 4
TRANSMILLE 3010A PRECISION MULTIPRODUCT CALIBRATOR - 5

Time (Minutes) Current (Amps) Measurement Conditions : Ambient Temperature 20'C, Mains Voltage 230V, Mains Frequency 50Hz Allow at least 7 minutes 'off' period between current output Shorter periods will reduce the output time availiable. A higher ohmic value load (for example, a 0.1R Shunt) allows greater output time as more heat is dissapated within the shunt / load. With lower loads more heat is dissapated within the instrument, reducing output time Into a 0.1R Load outputs of up to 20A are available for periods of greater than 30 minutes continously, considerations of self heating of...

Open the catalog to page 5
TRANSMILLE 3010A PRECISION MULTIPRODUCT CALIBRATOR - 6

1 year Total Accuracy Specifications at TCal ±5°C & Range Parameters Range Stability (Accuracy relative to calibration Standards) All specifications apply from 10% of full scale. 5 AC Frequency Accuracy : 30ppm Notes Note 1: Current limited by 50 ohms output resistance. Note 2 : Internally adjustable from 2mA to 30mA - Factory set to 20mA as standard For safety the trip is controlled by a fail-safe circuit independant of the processor which shuts the high voltage output off in the event of an overload. Note 3 : Frequency and voltage combinations are limited. Note 4 :...

Open the catalog to page 6
TRANSMILLE 3010A PRECISION MULTIPRODUCT CALIBRATOR - 7

2 Wire output / Remote sensing not available. Maximum floating voltage : 100V. Isolation : Floating or grounded selection available as standard. Specifications apply at TCal ± 5°C. Outside this range an allowance of 0.18 x 1 Year Spec. per °C should be added. High Voltage Safety High voltage output is ramped to allow instruments under test to auto-range. Standby is automatically activated when setting voltages greater than 20V or 200V from a lower voltage. Standby is automatically selected for high voltage (>20V) after 20 minutes on the same setting for frequencies up to 5kHz or 3 mins...

Open the catalog to page 7
TRANSMILLE 3010A PRECISION MULTIPRODUCT CALIBRATOR - 8

1 year Total Accuracy Specifications at TCal ±5°C & Range Parameters Range All specifications apply from 10% of full scale. AC Frequency Accuracy : 30ppm Settling Time: For 50% change in output: Less than 3 second from standby to within spec Inductive Loads : Up to 1H may be connected without additional protection providing the frequency/inductance combination does not exceed the maximum burden voltage. Due to continuous development specifications may be subject to change. 3010A Extended Specifications ACI Specifications : V1.81

Open the catalog to page 8
TRANSMILLE 3010A PRECISION MULTIPRODUCT CALIBRATOR - 9

Stability (Accuracy relative to calibration Standards) Notes Note 1 : Temperature sensor on 30A range - microprocessor monitors & protects from overheating. Higher resistance loads allow a longer ON period. See graph for details. Note 2 : Specifications apply to loads of less than 10% of the maximum burden voltage. Due to continuous development specifications may be subject to change. 3010A Extended Specifications ACI Specifications : V1.81 www.Transmille.com

Open the catalog to page 9
TRANSMILLE 3010A PRECISION MULTIPRODUCT CALIBRATOR - 10

Driving Coils and Inductive Loads When driving any load exceeding the maximum compliance voltage will cause the calibrator to trip into standby The maximum compliance voltage on the 10Amp range is specified at a max 2.8V RMS, 7.8V Peak to Peak at 220V supply Slightly higher compliances are available when powered from a 240V supply. When using EA002 with leads supplied it is possible to drive 30Amps/50Hz from a 230V supply, falling to 10Amps at 400Hz Specifications apply at TCal ± 5°C Outside this range an allowance of 0.18 x 1 Year Spec. per °C should be added. Time (Minutes) Current (Amps)...

Open the catalog to page 10
TRANSMILLE 3010A PRECISION MULTIPRODUCT CALIBRATOR - 11

3010A EXTENDED SPECIFICATIONS Frequency Specifications TRANSMILLE LTD * Frequency band available from Firmware Version 12.3.16 / 13.0.06 Specifications apply at TCal ± 5°C Outside this range an allowance of 0.18 x 1 Year Spec. per °C should be added. Due to continuous development specifications may be subject to change. 3010A Extended Specifications Frequency Specifications : V1.81

Open the catalog to page 11
TRANSMILLE 3010A PRECISION MULTIPRODUCT CALIBRATOR - 12

3010A EXTENDED SPECIFICATIONS DC Resistance Specifications TRANSMILLE LTD For the highest possible accuracy and dependability of the measured value, regardless of the measurement technique used, the 3000 Series calibrators use passive standard resistors, the calibrated value of which is displayed when selected. 1 year Total Accuracy Specifications at TCal ±5°C & Range Parameters For 2-Wire connection allow 35m on all resistance specifications. The 2 and 4 Wire value for each resistor is calibrated. The 2-Wire value is measured at the terminals The 4-Wire values are taken using the zero...

Open the catalog to page 12
TRANSMILLE 3010A PRECISION MULTIPRODUCT CALIBRATOR - 13

Capacitance Specifications For the highest possible accuracy and dependability of the measured value, regardless of the measurement technique used, the 3000 Series calibrators use passive standard capacitors, the calibrated value of which is displayed when selected. Capacitance is calibrated as value at the terminals ie. displayed value incorporates capacitance of circuit up to and including the terminals Specifications apply at TCal ±5°C. Outside this range an allowance of 0.18 x 1 Year Spec. per °C should be added. Due to continuous development 3010A Extended Specifications Capacitance...

Open the catalog to page 13