General Specifications Double the time since last used, up to 20 minutes maximum Standard Interfaces Optional Interfaces Temperature Performance Relative Humidity Operation : 3000m (10,000ft) Maximum Transit : 12000m (40,000ft) Maximum The calibrator line input plug must be earthed See D.O.C for full details Line Power Line Voltage Selectable : 100V/120V/230V/240V Line Frequency : 50Hz to 60Hz Line Voltage Variation : -6% +10% Power Consumption Front Panel Connections Voltage / 2 Wire Resistance / Capacitance 1x Black : 1x Red 4mm Binding Posts Low Current (<=2A) / Resistance Compensation 1x...
Open the catalog to page 2Interpreting Specifications Interpreting Specifications Transmille have taken great care over presenting the extended specifications in a manner that is easy to read while including high levels of details Transmille specify specifications as both Total Accuracy and Relative Specifciation, with varying calibration intervals, from 24 Hours to 2 Years By 'Total Accuracy', this means that all internal components of the calibrator have been compensated for. This includes stability, line voltage variations, temperature, humidity as well as the uncertainty of calibration as performed by Transmille Ltd....
Open the catalog to page 31 year Total Accuracy Specifications at Tcal ±5°C Range Typical Output 50 Ohms 0.2 Ohms 0.2 Ohms 0.5 Ohms 0.7 Ohms Stability (Accuracy relative to calibration Standards) Range Notes Note 1 : Allowance must be made for output resistance when driving into a load. Note 2 : Limited by 50 Ohm output impedance. Note 3 : Internally adjustable from 2mA to 30mA - Factory set to 20mA as standard. For safety the trip is controlled by a fail-safe circuit independant of the processor which shuts the high voltage output off in the event of an overload. Note 4 : Typical RMS noise figures at 50% of full scale,...
Open the catalog to page 41 year Total Accuracy Specifications at TCal ±5°C Range Compliance Voltage 4.2 Volts 4.2 Volts 4.2 Volts 4.2 Volts 4.2 Volts 3.9 Volts 3.9 Volts Notes Note 1 : Typical RMS noise figures at 50% of full scale. Note 2 : Power & temperature sensor on 30A range - microprocessor monitors & protects from overheating. Higher resistance loads allow a longer ON period. See graphs 1 and 2 for details. Note 3 : Specifications apply to loads of less than 10% of the maximum burden voltage. Note 4: Zero or floor allowance. Specifications apply at TCal ± 5°C Outside this range an allowance of 0.18 x 1 Year Spec....
Open the catalog to page 5Time (Minutes) Current (Amps) Measurement Conditions : Ambient Temperature 20'C, Mains Voltage 230V, Mains Frequency 50Hz Allow at least 7 minutes 'off' period between current output Shorter periods will reduce the output time availiable. A higher ohmic value load (for example, a 0.1R Shunt) allows greater output time as more heat is dissapated within the shunt / load. With lower loads more heat is dissapated within the instrument, reducing output time Into a 0.1R Load outputs of up to 20A are available for periods of greater than 30 minutes continously, considerations of self heating of the...
Open the catalog to page 61 year Total Accuracy Specifications at TCal ±5°C Range Typical Output Resistance Overload 1 Year Accuracy Protection ppm set uV Due to continuous development specifications may be subject to change. 4610M Extended Specifications www.Transmille.com ACV Specifications : V1.5
Open the catalog to page 7Stability (Accuracy relative to calibration Standards) Range Due to continuous development specifications may be subject to change. 4610M Extended Specifications www.Transmille.com ACV Specifications : V1.5
Open the catalog to page 84610M EXTENDED SPECIFICATIONS Notes Note 1: Note 2 : Note 3 : Note 4 : Note 5 : Note 7 : Note 9 : Current limited by 50 ohms output resistance. Internally adjustable from 2mA to 30mA - Factory set to 20mA as standard For safety the trip is controlled by a fail-safe circuit independant of the processor which shuts the high voltage output off in the event of an overload. Frequency and voltage combinations are limited. Specifications apply up to 10% of maximum load current. Above this level, allowance must be made for output resistance. Zero or floor allowance. THD less than 0.39% of output - 10Hz...
Open the catalog to page 91 Year Total Accuracy Specifications at TCal ±5°C Range Voltage (peak) Settling Time: For 50% change in output: Less than 3 second from standby to within spec Inductive Loads : Up to 1H may be connected without additional protection providing the frequency/inductance combination does not exceed the maximum burden voltage. Due to continuous development specifications may be subject to change. 4610M Extended Specifications www.Transmille.com AC Current : V1.5
Open the catalog to page 10Stability (Accuracy relative to calibration Standards) Range Notes Note 1 : Temperature sensor on 30A range - microprocessor monitors & protects from overheating. Higher resistance loads allow a longer ON period. See graph 5 for details. Note 2 : Specifications apply to loads of less than 10% of the maximum burden voltage. Note 3 : Frequency limited to 10kHz above 1A Note 4 : Frequency limited to 5kHz above 10A Due to continuous development specifications may be subject to change. 4610M Extended Specifications www.Transmille.com AC Current : V1.5
Open the catalog to page 11Driving Coils and Inductive Loads When driving any load exceeding the maximum compliance voltage will cause the calibrator to trip into standby The maximum compliance voltage on the 30Amp range is specified at a max 2.8V RMS, 7.8V Peak to Peak at 220V supply Slightly higher compliances are available when powered from a 240V supply. When using EA002 with leads supplied it is possible to drive 30Amps/50Hz from a 230V supply, falling to 10Amps at 400Hz Specifications apply at TCal ± 5°C Outside this range an allowance of 0.18 x 1 Year Spec. per °C should be added. Time (Minutes) Current (Amps) Measurement...
Open the catalog to page 12Frequency Output Total Accuracy Specifications at TCal ±5°C Range * Frequency continuously variable. Maximum frequency range available on the 2V AC Range Specifications apply at TCal ± 5°C Outside this range an allowance of 0.18 x 1 Year Spec. per °C should be added. Duty Cycle Accuracy Better than 0.1% Setting Level Accuracy Better than 0.05V Level Accuracy Better than 0.1V PWM Output provides a square wave output with variable level, duty cycle and DC offset Due to continuous development specifications may be subject to change. 4610M Extended Specifications www.Transmille.com Frequency Output...