Catalog excerpts
Gross prices! · phone +43 / 26 89 / 27 44 - 0 · fax +43 / 26 89 / 27 44 - 9 · info@trafomodern.com · www.trafomodern.com www.trafomodern.com Product Catalogue valid as from 1.5.2008 Transformers Chokes Power supplies
Open the catalog to page 1leadership in transformation trafomodern Transformatorenges. m.b.H. Industriestraße II/11 · A 7053 Hornstein phone +43 / 26 89 / 27 44 - 0 fax +43 / 26 89 / 27 44 - 9 info@trafomodern.com www.trafomodern.com Since 1945 trafomodern Transformatorengesellschaft m.b.H. located in Hornstein, Austria develops, manufactures, produces and sells transformers, chokes, power supplies and other electrical components. Additionally trafomodern offers services like for example calculations around all kind of inductive components or wiring of products. trafomodern is an international mid-size enterprise...
Open the catalog to page 3Gross prices! · phone +43 / 26 89 / 27 44 - 4 Gross prices! l Tel. +43 / 26 89 / 27 44 - 0 0l F· afxa x+ +434 3/ 2 / 62 68 98 9/ 2 / 72 74 4 4- 9- 9l i·n infofo@@trtarfaofommoodderenrn.c.ocomm l w· wwwww.t.rtarfaofommoodderenrn.c.ocomm Titel Untertitel Typ Designed and tested according to · IEC/EN 61558-2-2 / 2-4 / 2-6 · VDE 0570-2-2 / 2-4 / 2-6 · UL 506 · CSA 22.2 No. 66 For use according to · IEC/EN 60204-1 / ÖVE EN13 · VDE 0113 / VDE 0100 Teil 410 Typical applications · Control voltage circuits · Functional low voltage · Protective separation Transformers Single-phase Transformers...
Open the catalog to page 4Gross prices! · phone +43 / 26 89 / 27 44 - Gross prices! l Tel. +43 / 26 89 / 27 44 - 0 0l F· afxa x+ +434 3/ 2 / 62 68 98 9/ 2 / 72 74 4 4- 9- 9l i·n infofo@@trtarfaofommoodderenrn.c.ocomm l w· wwwww.t.rtarfaofommoodderenrn.c.ocomm 5 Typ Titel Untertitel Designed and tested according to · IEC/EN 61558-2-2 / 2-4 / 2-6 · VDE 0570-2-2 / 2-4 / 2-6 · UL 506 · CSA 22.2 No. 66 For use according to · IEC/EN 60204-1 / ÖVE EN13 · VDE 0113 / VDE 0100 Teil 410 Typical applications · Control voltage circuits · Functional low voltage · Protective separation Chokes Engineering data Type DEG DEK DDK...
Open the catalog to page 5Gross prices! · phone +43 / 26 89 / 27 44 - 8 0 · fax +43 / 26 89 / 27 44 - 9 · info@trafomodern.com · www.trafomodern.com Transformers Single-phase control transformers STN Designed and tested according to · IEC/EN 61558-2-2 · VDE 0570-2-2 · UL 506 · CSA 22.2 No. 66 For use according to · IEC/EN 60204-1 / ÖVE EN13 · VDE 0113 / VDE 0100 Teil 410 Typical applications · Control voltage circuits · Functional low voltage Basic equipment · Separate windings · Insulation class B · Ambient temperature –25 to 40 °C · Connection terminal (<63 A) · Frequency 50/60 Hz · ±5 % tapping on the primary...
Open the catalog to page 8Gross prices! · phone +43 / 26 89 / 27 44 - 10 0 · fax +43 / 26 89 / 27 44 - 9 · info@trafomodern.com · www.trafomodern.com Transformers Single-phase control transformers STI Designed and tested according to · IEC/EN 61558-2-2 / 2-4 / 2-6 · VDE 0570-2-2 / 2-4 / 2-6 · UL 506 · CSA 22.2 No. 66 For use according to · IEC/EN 60204-1 / ÖVE EN13 · VDE 0113 / VDE 0100 Teil 410 Typical applications · Control voltage circuits · Functional low voltage · Safety low voltage · Protective separation Basic equipment · Separate windings · Insulation class B · Ambient temperature –25 to 40 °C · Connection...
Open the catalog to page 10Gross prices! · phone +43 / 26 89 / 27 44 - 12 0 · fax +43 / 26 89 / 27 44 - 9 · info@trafomodern.com · www.trafomodern.com Transformers Single-phase control transformers STZ Designed and tested according to · IEC/EN 61558-2-2 / 2-4 / 2-6 · VDE 0570-2-2 / 2-4 / 2-6 · UL 506 · CSA 22.2 No. 66 For use according to · IEC/EN 60204-1 / ÖVE EN13 · VDE 0113 / VDE 0100 part 410 Typical applications · Control voltage circuits · Functional low voltage · Safety low voltage · Protective separation Basic equipment · Separate windings · Insulation class B · Ambient temperature –25 to 40 °C · Connection...
Open the catalog to page 12Gross prices! · phone +43 / 26 89 / 27 44 - 14 0 · fax +43 / 26 89 / 27 44 - 9 · info@trafomodern.com · www.trafomodern.com STA Designed and tested according to · IEC/EN 61558-2-2 / 2-4 / 2-6 · VDE 0570-2-2 / 2-4 / 2-6 · EN50014 · EN50019 For use according to · IEC/EN 60204-1 / ÖVE EN13 · VDE 0113 / VDE 0100 Teil 410 · EU Ratsrichtlinie 94/9/EG Typical applications · Control voltage circuits · Functional low voltage · Functional low voltage · Protective separation Basic equipment · Separate windings · Insulation class B · Ambient temperature –25 to 40 °C · Connection terminals · Frequency...
Open the catalog to page 14Gross prices! · phone +43 / 26 89 / 27 44 - 16 0 · fax +43 / 26 89 / 27 44 - 9 · info@trafomodern.com · www.trafomodern.com Transformers Single-phase matching transformers ET Designed and tested according to · IEC/EN 61558-2-1 · VDE 0570-2-1 · EN 60076-1 · UL 506 · CSA 22.2 No. 66 Typical applications · Voltage adjustment Basic equipment · Separate windings · Insulation class B / F from 6.3 kVA · Ambient temperature –25 to 40 °C · Connection terminal (<63 A) · Frequency 50/60 Hz Further equipment · Enclosure IP23 page 56 · Additional tapping page 59 · Additional winding page 61 · Static...
Open the catalog to page 16Gross prices! · phone +43 / 26 89 / 27 44 - 18 0 · fax +43 / 26 89 / 27 44 - 9 · info@trafomodern.com · www.trafomodern.com ETSP Designed and tested according to · IEC/EN 61558-2-13 · VDE 0570-2-13 · EN 60076-1 · UL 506 · CSA 22.2 No. 66 Typical applications · Cost-efficient solutions for voltage adjustment Basic equipment · Insulation class B / F from 6.3 kVA · Ambient temperature –25 to 40 °C · Connection terminal (<63 A) · Frequency 50/60 Hz Further equipment · Enclosure IP23 page 56 · Additional tapping page 59 · Additional winding page 61 · Static shield winding page 59 · Temperature...
Open the catalog to page 18All Trafomodern Transformatorengesellschaft catalogs and technical brochures
-
Product c atalogue
68 Pages
-
DTA Transformers
1 Pages
-
DDK Chokes
1 Pages
-
GW GD - DC power supply units
1 Pages