GW GD - DC power supply units
1Pages

{{requestButtons}}

Catalog excerpts

GW GD  -  DC power supply units - 1

Gross prices! · phone +43 / 26 89 / 27 44 - 0 · fax +43 / 26 89 / 27 44 - 9 · info@trafomodern.com · www.trafomodern.com Gross prices! · phone +43 / 26 89 / 27 44 - 46 0 · fax +43 / 26 89 / 27 44 - 9 · info@trafomodern.com · www.trafomodern.com DC power supply units GW GD Designed and tested according to · IEC/EN 61558-2-6 · VDE 0570-2-6 · UL 506 · CSA 22.2 No. 66 For use according to · IEC/EN 60204-1 · VDE 0113 Typical applications · Control voltage circuits · Functional low voltage Basic equipment · Separate windings · Insulation class B · Ambient temperature –25 to 40 °C · Connection terminal (<63 A) · Frequency 50/60 Hz · Single-phase GW units with fuse on the DC side and LED Further equipment · Enclosure IP23 page 56 · Additional tapping page 59 · Temperature Control page 61 47 DC power supply units GW, GD V AC V DC A Euro 230 24 3 GW4-030-BA3 84.80 0.36 (5 %) 200016 5 GW4-050-BA3 106.20 0.37 200017 8 GW4-080-BA3 122.10 0.82 200018 10 GW4-100-BA3 131.70 0.96 200019 400 (± 5 %) 24 5 GD4-050-BD3 104.80 0.65 (3 %) 200007 10 GD4-100-BD3 125.30 1.12 200009 15 GD4-150-BD3 146.50 1.30 200011 20 GD4-200-BD3 167.80 2,10 200012 30 GD4-300-BD3 200.20 3.00 200014 Design input voltage 50/60 Hz Design output voltage (residual ripple) Design output current Type Order no. Price**) per unit Cu-factor1) Type U1 I1 Switch Rated current Switch only short-circuit protection **) All prices are quoted net 1) Material surcharge –› page 64 Type a b b1 c e f ø g Fig1 GW4-030-BA3 GW4-050-BA3 GW4-080-BA3 GW4-100-BA3 Fig2 GD4-050-BD3 GD4-100-BD3 GD4-150-BD3 GD4-200-BD3 GD4-300-BD3 Residual ripple Shortcircuit losses No-load losses Total weight 2 2.5 3.65 4.45 2.4 4.4 5.8 7.6 11.2 kg W W Electromagnetic compatibility Interference emission ESD RFI Burst Surge Impulse voltage Environmental data Ambient temperature Storage and transport temperature Degree of soiling Vibration Shock Installation altitude Class B, ( EN 55 011, 22 ) 6 kV contact ( level 3 ) 8 kV air ( level 3 ), IEC/EN 61 000-4-2 10 V/m, modulated, IEC/EN 61 000-4-3 2 kV ( level 3 ), IEC/EN 61 000-4-4 2 kV ( inst.-class 3 ), IEC/EN 61 000-4-5 4.9 kV, IEC/EN 60 947 -25 °C to +55 °C linear characteristic of the Derating Curve from 40 °C to 55 °C from 100 % output to 93 % output 25 °C to +85 °C 2, EN 50 178 0.0075 mm, ( 10-57 Hz ), 10 Zyklen, IEC 60 068-2-6 11 ms/15 g, IEC 60 068-2-27, ( 3 shocks ) max. 2000 m above sea level, if higher: take derating into account Fig.1 Fig.2 V A A GW 4-030-BD3 230 0.45 PKZM0-0.63 0.45 FAZN S1 • GW 4-050-BD3 230 0.8 PKZM0-1 0.8 FAZN S1 - GW 4-080-BD3 230 1.2 PKZM0-1.6 1.2 FAZN S1 - GW 4-100-BD3 230 1.4 PKZM0-1.5 1.4 FAZN S2 - GD 4-050-BD3 3 x 400 0.24 PKZM0-0.25 0.24 FAZN S1 • GD 4-100-BD3 3 x 400 0.46 PKZM0-0.63 0.46 FAZN S1 • GD 4-150-BD3 3 x 400 0.65 PKZM0-1 0.65 FAZN S1 - GD 4-200-BD3 3 x 400 0.9 PKZM0-1 0.9 FAZN S1 - GD 4-300-BD3 3 x 400 1.8 PKZM0-2.5 1.8 FAZN S2 - GW GD In order to help the user to select the correct protective motor switch, protective motor switches made by Moeller are listed in the above table as examples. Of course other protective motor switches of other manufacturers are equally suited and approved for the performance of the task. < 5 % < 5 % < 5 % < 5 % < 3 % < 3 % < 3 % < 3 % < 3 % 26 41 46 57 27 45 63 89 101 7.6 9 12.8 14.1 5 14.2 13.9 25.5 38.2 85 85 106 121 125 155 155 190 190 4.8 4.8 5.8 5.8 58888 60.5 69 69.5 70 45 57 72 58 78 64 64 80.5 90 100 130 130 170 170 119 134 150 168 135 165 165 220 235 74 83 87 86 61 77 92 83 103 85 93 95 100 68 77 92 100 110 all dimensions in mm Output current Output current Output voltage Output voltage

Open the catalog to page 1

All Trafomodern Transformatorengesellschaft catalogs and technical brochures

  1. DDK Chokes

    1 Pages

Archived catalogs