Catalog excerpts

Railway technology Pressure and temperature monitoring solutions NN Pressure switches NN Pressure transmitters NN Thermostats
Open the catalog to page 1
Air-conditioning systems Pressure monitoring for cooling compressors, room temperature monitoring Brake systems Pneumatic and hydraulic brake systems, emergency brake systems Propulsion Monitoring of pressure and temperature in water or oil circuits of motors, gearboxes and in cooling circuits of current converters Lubrication systems Pressure monitoring for automatic lubrication systems Control and safety systems overload control, door-closing systems, fire extinguishing systems Pantographs Pneumatically actuated pantographs Diagnostic systems Mobile units for testing pressures on rail...
Open the catalog to page 2
Overview railway products Pressure transmitters NAR 8258 www.trafag.com/H72307 Very compact and robust. 1st choice for all applications with electrical connector M12x1 or Industrial standard. www.trafag.com/H72300 Very compact and robust. For applications where accuracy of 0.15% is required (e.g. braking systems). www.trafag.com/H72319 Very ro bust, wide range of process connections. 1st choice for all applications with electrical connector DIN EN 175301-803-A. www.trafag.com/H72337 Very versatile, frontal membrane and corrosion resistant materials available. 1st choice for absolute...
Open the catalog to page 3
EPR 8283 Railway Pressure Transmitter Features NN NN NN NN NN Dielectrical strength: 710 VDC, meets EN 50155 (Railways) Compact design Good temperature resistance Different accuracy classes Completely welded steel sensor system without additional seals Technical Data Measuring principle Thin film on steel Media temperature Measuring range Ambient temperature Output signal Approval / conformity EN 50155 (Railway) EN 45545-2 (Fire protection) 36–38 with male thread 48.5–50.5 with female cable length Data sheet Instructions
Open the catalog to page 4
Ordering information/type code 1) Customized pressure ranges upon request 2) Upon request 3) Only with pressure connection 17 (G1/4") 4) Max. allowable pressure range 60 bar at 120 bar overpressure 5) According to norm SAE J1926-3, max. 35 MPa 6) Cable length see accessories (max. length 50 m, in 5-meter sections) 7) IP68, max. 3 m, Media +10°C ... +35°C 8) Cable length max. 3 m, for pressure ranges < 16 bar 9) Not according to standard EN 45545-2 sensors ^[►controls
Open the catalog to page 5
EPR 8293 Railway Pressure Transmitter Features NN NN NN NN NN Dielectrical strength: 500 VAC, 50 Hz, meets EN 50155 (Railways) Compact design Good temperature resistance Different accuracy classes Completely welded steel sensor system without additional seals Technical Data Measuring principle Thin film on steel Media temperature Measuring range Ambient temperature Output signal Approval / conformity Cable clamping range 6...11mm Data sheet Instructions
Open the catalog to page 6
Burst pressure [bar] 100 100 100 200 200 300 300 500 500 1000 1000 1500 2000 Sensor Relative pressure, accuracy: 0.3 % Relative pressure, accuracy: 0.5 % Pressure G1/4" male (Seal) connection R1/4" male 2) 1/4" NPT male 3) 1/2" NPT male 3) Electrical Male electrical plug EN 175301-803-A (DiN43650-A), Mat. PA connection Male electrical plug EN 175301-803-A, Mat. PA, Extended vibration resistance Male electrical plug MiL-C 26482, 6-pole, metal 4) Output Signal output Load resistance I (supply) U (supply) 1) Extended overpressure as well as customized pressure ranges upon request 2)...
Open the catalog to page 7
Features ■ Measuring accuracy 0.3 % ■ Optional: Switching output 1 or 2 PNP transistors ■ Excellent long-term stability ■ Dielectrical strength: 710 VDc, meets EN 50155 (Railways) Parameterization of switching points The switching points, delay times and output functions can be parameterized via Smartphone app (Android). the SMI Sensor Master interface required for the parameterization as well as the Smartphone are not part of the delivery. the android App is available for free in the Google Play Store. ■ ordering No. SMi Sensor Master interface: F90170 ■ Data sheet SMi Sensor Master...
Open the catalog to page 8
Female electrical plug M12x1,5-pole 2) 33 Female electrical connector industrial standard (for electrical connection 01) Parameterisation according to customer specification for output signal PS, T1 (see table parameter) ZC Output signalAccessories 1) customized pressure ranges upon request 3) only with electrical connection 32 4) Max. allowable pressure range 60 bar at 120 bar overpressure 5) Max. allowable pressure range 160 bar at 500 bar overpressure 6) only for pressure connections 17, 30, 32 sensors ^[►controls
Open the catalog to page 9
Features ■ Smallest design ■ Accuracy classes 0.1%, 0.3% ■ Excellent temperature resistance ■ improved vibration resistance ■ completely welded steel sensor system without additional seals
Open the catalog to page 10
Measuring range 1) Pressure measurement range [bar] Pressure measurement range [psi] Sensor Relative pressure, accuracy: 0.3 % Pressure connection Output Signal output Load resistance I (supply) U (supply) Accessories Female electrical plug M12x1,5-pole, for electrical connections 32 and 35 33 Female electrical connector industrial standard 34 Meets EN 50155 (railways) dielectrical strength: 500 VAC, 50 Hz 5) 11 Pressure peak damping element 0 1.0 mm 6) 40 Pressure peak damping element 0 0.3 mm 6) 43 Pressure peak damping element 0 0.5 mm 6) 45...
Open the catalog to page 11
ECR 8478 Railway Pressure Transmitter Features NN NN NN NN Dielectrical strength: 710 VDC, meets EN 50155 (Railways) Measuring ranges from 100 mbar Relative or absolute pressure measurement Frontal membrane optional Technical Data Measuring principle Thick film on ceramic Media temperature Measuring range Ambient temperature Output signal Approval / conformity EN 50155 (Railway) EN 45545-2 (Fire protection) 36–38 with male thread 48.5–50.5 with female thread Data sheet Instructions 31-33 with male thread
Open the catalog to page 12
Measuring range 11 Pressure measurement range [bar] Pressure measurement range [psi] Sensor with temperature compensation without temperature compensation Pressure connection 11 Extended overpressure as well as customized pressure ranges upon request 2) Upon request 3) Max. 40 bar or 500 psi 4) > 1 bar 5) Only with pressure connection 17 (1.4305) 6) Only for pressure ranges < 10 bar or 150 psi sensors ^[►controls
Open the catalog to page 13All Trafag AG sensors & controls catalogs and technical brochures
-
Pressostat P/PS 900/904/912
6 Pages
-
Pressostat PK 944/947
6 Pages
-
Pressostat 987/988
5 Pages
-
PICOSTAT PST4 9B4
5 Pages
-
8212/13 NAVI-MINITRAG H
4 Pages
-
8822 PRESSURE TRANSDUCER
4 Pages
-
PICOTRANS NPN 8264
6 Pages
-
PRESSURE TRANSMITTER NAH 8254
13 Pages
-
Flush Membrane Transmitter
5 Pages
-
Trafag AG: Temperature monitoring
175 Pages
-
TMT502
4 Pages
-
Navitrag
4 Pages
-
Sensor Master Interface
2 Pages
-
Potentially hazardous areas
12 Pages
-
Hydraulics
24 Pages
-
8100 navitrag T
4 Pages
-
TMP301
10 Pages
-
TMP203
5 Pages
-
Railway Technology
2 Pages
-
Shipbuilding
16 Pages
-
H70696a_EN_CAN2USB_Tool
2 Pages
-
H70677i_EN_8202_N_Navitrag
2 Pages
-
H70650a
4 Pages
-
H70649a
4 Pages
-
H70636e_EN_878X_Hybrid_GDM
4 Pages
-
H70603a
2 Pages
-
H70600
2 Pages
-
H72302
5 Pages
-
H72304
9 Pages
-
H72303
10 Pages
-
H72207
4 Pages
-
H72206
4 Pages
-
H70694
2 Pages
-
H72335
4 Pages
-
H70697
2 Pages
-
H72307
9 Pages
-
Data Sheet 900/904/912
5 Pages
-
Instruction ECTN 8477
2 Pages
-
Instruction EPI 8287
2 Pages
-
Instruction PST4M 9M4
2 Pages
-
Instruction PST4K 9K4
2 Pages
-
Instruction PSTD 9D0
2 Pages
-
Instruction PST4 9B4
2 Pages
-
Instruction PST4B 9B4
2 Pages
-
Flyer EXPK 944/947/953
2 Pages
-
Data Sheet EXPK 944/947/953
6 Pages
-
Instruction PK 944/947
2 Pages
-
Flyer EXPD 920/924/932
2 Pages
-
Data Sheet EXPD 920/924/932
5 Pages
-
Instruction PD 920/924/932
2 Pages
-
Flyer EXP 900/904/912
2 Pages
-
Data Sheet EXP 900/904/912
5 Pages
-
Instruction P/PS 900/904/912
2 Pages
-
Flyer P/PS 900/904/912
2 Pages
-
Instruction DCS 8864
4 Pages
-
Flyer DCS 8864
2 Pages
-
Data Sheet DCS 8864
5 Pages
-
Instruction EXNA 8854
4 Pages
-
Flyer EXNA 8854
2 Pages
-
Instruction EXNA 8852/8853
4 Pages
-
Flyer EXNA 8852/8853
2 Pages
-
Flyer NAP 8842/8843
2 Pages
-
Data Sheet NAP 8842/8843
6 Pages
-
Flyer NAL 8838
2 Pages
-
Instruction ECON 8498
2 Pages
-
Flyer ECON 8498
2 Pages
-
Data Sheet ECON 8498
4 Pages
-
Instruction ECT 8472
2 Pages
-
Flyer ECT 8472
2 Pages
-
Instruction ECTR 8471
2 Pages
-
Flyer ECTR 8471
2 Pages
-
Data Sheet ECTR 8471
6 Pages
-
Instruction ECL 8438
2 Pages
-
Flyer ECL 8438
2 Pages
-
Instruction EXL 8432
2 Pages
-
Flyer EXL 8432
2 Pages
-
Instruction EPN-S 8320
2 Pages
-
Flyer EPN-S 8320
2 Pages
-
Instruction EPN/EPNCR 8298
2 Pages
-
Flyer EPN/EPNCR 8298
2 Pages
-
Instruction EPI 8297
2 Pages
-
Flyer EPI 8297
2 Pages
-
Data Sheet EPI 8297
4 Pages
-
Instruction EPR 8293
2 Pages
-
Flyer EPR 8293
2 Pages
-
Instruction EXNT 8292
2 Pages
-
Flyer EXNT 8292
2 Pages
-
Instruction CMP 8270
2 Pages
-
Flyer CMP 8270
2 Pages
-
Instruction NPN 8264
2 Pages
-
Flyer NPN 8264
2 Pages
-
Data Sheet NPN 8264
6 Pages
-
Instruction NSL 8257
2 Pages
-
Flyer NSL 8257
2 Pages
-
Instruction NAE 8256
2 Pages
-
Flyer NAE 8256
2 Pages
-
Instruction NAE 8255
2 Pages
-
Flyer NAE 8255
2 Pages
-
Data Sheet NAE 8255
5 Pages
-
Instruction NAH 8254
2 Pages
-
Instruction NAH 8253
2 Pages
-
Flyer NAH 8253
2 Pages
-
Instruction NAT 8252
2 Pages
-
Instruction FPT 8235
2 Pages
-
Flyer FPT 8235
2 Pages
-
Data Sheet FPT 8235
5 Pages
-
Instruction ND 8204
2 Pages
-
Flyer ND 8204
2 Pages
-
Data Sheet ND 8204
4 Pages
-
Instruction N 8202
2 Pages
-
Flyer N 8202
2 Pages
-
Data Sheet N 8202
4 Pages
-
Instruction L...R 755
2 Pages
-
Flyer L...R 755
2 Pages
-
Data Sheet L...R 755
5 Pages
-
Instruction L/LF 736/754
2 Pages
-
Flyer L/LF 736/754
2 Pages
-
Data Sheet L/LF 736/754
5 Pages
-
Instruction MP/MSP 663/664
2 Pages
-
Flyer MP/MSP 663/664
2 Pages
-
Data Sheet MP/MSP 663/664
5 Pages
-
Instruction GS 657/658
2 Pages
-
Flyer GS 657/658
2 Pages
-
Data Sheet GS 657/658
5 Pages
-
Instruction A/AS/ASE 645/650
2 Pages
-
Flyer A/AS/ASE 645/650
2 Pages
-
Data Sheet A/AS/ASE 645/650
5 Pages
-
Instruction MS...R 630/632
2 Pages
-
Flyer MS...R 630/632
2 Pages
-
Data Sheet MS...R 630/632
5 Pages
-
Instruction MSK 624/634
2 Pages
-
Flyer MSK 624/634
2 Pages
-
Data Sheet MSK 624/634
5 Pages
-
Instruction MST 624/634
2 Pages
-
Flyer MST 624/634
2 Pages
-
Data Sheet MST 624/634
5 Pages
-
Instruction M/MS 624/634
2 Pages
-
Flyer M/MS 624/634
2 Pages
-
Data Sheet M/MS 624/634
6 Pages
-
Instruction ISP/ISPT 474
2 Pages
-
Flyer ISP/ISPT 474
2 Pages
-
Data Sheet ISP/ISPT 474
6 Pages
-
Instruction ISN/ISNT 471/472
2 Pages
-
Flyer ISN/ISNT 471/472
2 Pages
-
Data Sheet ISN/ISNT 471/472
6 Pages
-
Instruction EXAS 409/419
12 Pages
-
Flyer EXAS 409/419
2 Pages
-
Data Sheet EXAS 409/419
5 Pages
-
Instruction IA/IAS 409/419
2 Pages
-
Flyer IA/IAS 409/419
2 Pages
-
Data Sheet IA/IAS 409/419
5 Pages
-
Instruction EXS 404/414
12 Pages
-
Flyer EXS 404/414
2 Pages
-
Data Sheet EXS 404/414
6 Pages
-
Instruction I/IS 404/414
2 Pages
-
Flyer I/IS 404/414
2 Pages
-
Data Sheet I/IS 404/414
6 Pages
-
Instruction ADS 319
2 Pages
-
Flyer ADS 319
2 Pages
-
Data Sheet ADS 319
5 Pages
-
Instruction D...R 302
2 Pages
-
Flyer D...R 302
2 Pages
-
Data Sheet D...R 302
5 Pages
-
Instruction A2/A2S 198/199
2 Pages
-
Flyer A2/A2S 198/199
2 Pages
-
Data Sheet A2/A2S 198/199
5 Pages
-
Instruction M2S 104/114
2 Pages
-
Flyer M2S 104/114
2 Pages
-
Data Sheet M2S 104/114
6 Pages
-
Potentially hazardous areas EX
12 Pages
-
SF6 Gas Density Monitoring
12 Pages
-
Trafag Insight Brochure
20 Pages
-
Trafag Products Catalogue 2016
161 Pages