Catalog excerpts
Applications ■ Machine tools ■ Hydraulics ■ HVAC ■ Refrigeration ■ Process technology ■ Water treatment INDUSTRIAL PRESSURE TRANSMITTER Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of pressure and temperature. The industrial pressure transmitter NAT 8252 features an exceptionally long-term stable thin-film-on-steel sensor cell with triple (optionally 5-fold) overpressure safety. Optionally, the NAT 8252 is available as a pressure switch with 1 or 2 switching outputs. The robust design and the wide temperature range from -40°C to +125°C qualify the NAT 8252 as the ideal solution for a wide range of demanding applications. ■ Smallest design ■ Completely welded steel sensor system without additional seals ■ Excellent long-term stability ■ Optional: 5-fold overpressure resistance ■ Optional: Switching output 1 or 2 PNP transistors Subject to change Data sheet H72303y 09/2020 www.trafag.com trafag@trafag.com trcifciqsensors controls
Open the catalog to page 18252. XX Measuring range 1) Pressure measurement range [bar] Pressure measurement range [psi] Sensor Relative pressure Pressure GW male, seal: DIN 3869 (accessories 61/63/83) connection G1/4" male, with integrated damping 0 0.5 mm, Seal: DIN 3869 (accessories 61/63/83) G1/4" male (Manometer) EN 837 G1/8" male DIN3852-E, seal: accessory 61 5) 1/4" NPT male 1/4" NPT female 5) 1/8" NPT male 5) 7/16"-20UNF female, SAE J512 with valve opener 4) 7/16"-20UNF female, SAE J512 without valve opener 4) 7/16"-20UNF male, DIN3866 4) 7/16"-20UNF SAE4 male (J1926), seal: accessory 61 9/16"-18UNF male,...
Open the catalog to page 2Male electrical connector, industrial standard, contact distance 9.4 mm, Mat. PA 01 Male electrical connector M12x1,4-pole, Mat. PA, IEC 61076-2-101 32 Male electrical connector M12x1,5-pole, Mat. PA, IEC 61076-2-101 35 Male electrical connector MIL-C 26482, 6-pole, metal 02 Male electrical connector Deutsch DT04-3P, 3-pole D3 Male electrical connector Deutsch DT04-4P, 4-pole D4 Cable Mat. PVC, IP67/IP68, 2 x 2 x 0.14 mm2, max. traction on cable: 2 N 7) 22 Cable Mat. Radox Tenuis, IP67/IP68, 4 x 0.5 mm2 7) Output signal Load resistance See graphic > 5.0 kQ to Us> 5.0 kQ to Us> 5.0 kQ to Us>...
Open the catalog to page 311 Customized pressure ranges upon request 2) For electrical connections 32 and 35 3) Only with electrical connections 32, 22,24, 08, 88 4) Max. allowable pressure range 60 bar at 180 bar overpressure 5) Max. allowable pressure range 160 bar at 480 bar overpressure 6) Not for pressure connections 53, 24, 44, 18 7) Cable length see accessories 8) The order quantity must be a multiple of 50, only for electrical connections 01,32, 35, 02, D3, D4, not for pressure connection 30 with electrical connections 02, D3, D4 9) Upon request 10) Only with electrical connections 32, 22, 24, 08, 88, D3 11)...
Open the catalog to page 4r Standard products (extra short lead time) trofaq sensors ^^controls
Open the catalog to page 5Standard products (extra short lead time) trofaq sensors ^^controls
Open the catalog to page 6Parameterization of switching points The switching points, delay times and output functions can be parameterized via Smartphone app (Android). The SMI Sensor Master Interface required for the parameterization as well as the Smartphone are not part of the delivery. The Android App is available for free in the Google Play Store. ■ Ordering No. SMI Sensor Master Interface: F90170 ■ Data sheet SMI Sensor Master Interface: H72618 trofaq sensors ^^controls
Open the catalog to page 711 See electrical connection 2) For electrical connections 32 and 35 trofaq sensors ^^controls
Open the catalog to page 8Analogue output TC zero point and span [% FS/K typ.] ± 0.03 Long term stability 1 year [% FS typ.] ± 0.1 Rise time Typ. 1 ms / 10 ... 90 % nominal pressure Measuring accuracy trofaq sensors ^^controls
Open the catalog to page 9NAT8252 Protection / electrical connection 03 C =3 Q_ =3 o -j—j—© Us Ipos. Supply)—> i i I I I I -j-1—0 Us (nag. Supply)—> 11 Provided female connector is mounted according to instructions 2) Ventilation via male electric plug/cable end H72303y page 12/14 trofaq sensors ^^controls
Open the catalog to page 12M12x1 Cable Cable Cable DT04-3P white green yellow brown white green brown red white green black white blue - yellow / green black black brown blue black 8252.xx.xxxx.xx.PS/T1 11 Provided female electrical plug is mounted according to instructions 2) Ventilation via male electric plug/cable end H72303y page 13/14 trofaq sensors ^^controls
Open the catalog to page 13Functions switching output Window trofaq sensors ^^controls
Open the catalog to page 14All Trafag AG sensors & controls catalogs and technical brochures
-
Pressostat P/PS 900/904/912
6 Pages
-
Pressostat PK 944/947
6 Pages
-
Pressostat 987/988
5 Pages
-
PICOSTAT PST4 9B4
5 Pages
-
8212/13 NAVI-MINITRAG H
4 Pages
-
8822 PRESSURE TRANSDUCER
4 Pages
-
PICOTRANS NPN 8264
6 Pages
-
PRESSURE TRANSMITTER NAH 8254
13 Pages
-
Flush Membrane Transmitter
5 Pages
-
Trafag AG: Temperature monitoring
175 Pages
-
TMT502
4 Pages
-
Navitrag
4 Pages
-
Sensor Master Interface
2 Pages
-
Potentially hazardous areas
12 Pages
-
Hydraulics
24 Pages
-
8100 navitrag T
4 Pages
-
TMP301
10 Pages
-
TMP203
5 Pages
-
Railway Technology
2 Pages
-
Railway vehicles
20 Pages
-
Shipbuilding
16 Pages
-
H70696a_EN_CAN2USB_Tool
2 Pages
-
H70677i_EN_8202_N_Navitrag
2 Pages
-
H70650a
4 Pages
-
H70649a
4 Pages
-
H70636e_EN_878X_Hybrid_GDM
4 Pages
-
H70603a
2 Pages
-
H70600
2 Pages
-
H72302
5 Pages
-
H72304
9 Pages
-
H72303
10 Pages
-
H72207
4 Pages
-
H72206
4 Pages
-
H70694
2 Pages
-
H72335
4 Pages
-
H70697
2 Pages
-
H72307
9 Pages
-
Data Sheet 900/904/912
5 Pages
-
Instruction ECTN 8477
2 Pages
-
Instruction EPI 8287
2 Pages
-
Instruction PST4M 9M4
2 Pages
-
Instruction PST4K 9K4
2 Pages
-
Instruction PSTD 9D0
2 Pages
-
Instruction PST4 9B4
2 Pages
-
Instruction PST4B 9B4
2 Pages
-
Flyer EXPK 944/947/953
2 Pages
-
Data Sheet EXPK 944/947/953
6 Pages
-
Instruction PK 944/947
2 Pages
-
Flyer EXPD 920/924/932
2 Pages
-
Data Sheet EXPD 920/924/932
5 Pages
-
Instruction PD 920/924/932
2 Pages
-
Flyer EXP 900/904/912
2 Pages
-
Data Sheet EXP 900/904/912
5 Pages
-
Instruction P/PS 900/904/912
2 Pages
-
Flyer P/PS 900/904/912
2 Pages
-
Instruction DCS 8864
4 Pages
-
Flyer DCS 8864
2 Pages
-
Data Sheet DCS 8864
5 Pages
-
Instruction EXNA 8854
4 Pages
-
Flyer EXNA 8854
2 Pages
-
Instruction EXNA 8852/8853
4 Pages
-
Flyer EXNA 8852/8853
2 Pages
-
Flyer NAP 8842/8843
2 Pages
-
Data Sheet NAP 8842/8843
6 Pages
-
Flyer NAL 8838
2 Pages
-
Instruction ECON 8498
2 Pages
-
Flyer ECON 8498
2 Pages
-
Data Sheet ECON 8498
4 Pages
-
Instruction ECT 8472
2 Pages
-
Flyer ECT 8472
2 Pages
-
Instruction ECTR 8471
2 Pages
-
Flyer ECTR 8471
2 Pages
-
Data Sheet ECTR 8471
6 Pages
-
Instruction ECL 8438
2 Pages
-
Flyer ECL 8438
2 Pages
-
Instruction EXL 8432
2 Pages
-
Flyer EXL 8432
2 Pages
-
Instruction EPN-S 8320
2 Pages
-
Flyer EPN-S 8320
2 Pages
-
Instruction EPN/EPNCR 8298
2 Pages
-
Flyer EPN/EPNCR 8298
2 Pages
-
Instruction EPI 8297
2 Pages
-
Flyer EPI 8297
2 Pages
-
Data Sheet EPI 8297
4 Pages
-
Instruction EPR 8293
2 Pages
-
Flyer EPR 8293
2 Pages
-
Instruction EXNT 8292
2 Pages
-
Flyer EXNT 8292
2 Pages
-
Instruction CMP 8270
2 Pages
-
Flyer CMP 8270
2 Pages
-
Instruction NPN 8264
2 Pages
-
Flyer NPN 8264
2 Pages
-
Data Sheet NPN 8264
6 Pages
-
Instruction NSL 8257
2 Pages
-
Flyer NSL 8257
2 Pages
-
Instruction NAE 8256
2 Pages
-
Flyer NAE 8256
2 Pages
-
Instruction NAE 8255
2 Pages
-
Flyer NAE 8255
2 Pages
-
Data Sheet NAE 8255
5 Pages
-
Instruction NAH 8254
2 Pages
-
Instruction NAH 8253
2 Pages
-
Flyer NAH 8253
2 Pages
-
Instruction NAT 8252
2 Pages
-
Instruction FPT 8235
2 Pages
-
Flyer FPT 8235
2 Pages
-
Data Sheet FPT 8235
5 Pages
-
Instruction ND 8204
2 Pages
-
Flyer ND 8204
2 Pages
-
Data Sheet ND 8204
4 Pages
-
Instruction N 8202
2 Pages
-
Flyer N 8202
2 Pages
-
Data Sheet N 8202
4 Pages
-
Instruction L...R 755
2 Pages
-
Flyer L...R 755
2 Pages
-
Data Sheet L...R 755
5 Pages
-
Instruction L/LF 736/754
2 Pages
-
Flyer L/LF 736/754
2 Pages
-
Data Sheet L/LF 736/754
5 Pages
-
Instruction MP/MSP 663/664
2 Pages
-
Flyer MP/MSP 663/664
2 Pages
-
Data Sheet MP/MSP 663/664
5 Pages
-
Instruction GS 657/658
2 Pages
-
Flyer GS 657/658
2 Pages
-
Data Sheet GS 657/658
5 Pages
-
Instruction A/AS/ASE 645/650
2 Pages
-
Flyer A/AS/ASE 645/650
2 Pages
-
Data Sheet A/AS/ASE 645/650
5 Pages
-
Instruction MS...R 630/632
2 Pages
-
Flyer MS...R 630/632
2 Pages
-
Data Sheet MS...R 630/632
5 Pages
-
Instruction MSK 624/634
2 Pages
-
Flyer MSK 624/634
2 Pages
-
Data Sheet MSK 624/634
5 Pages
-
Instruction MST 624/634
2 Pages
-
Flyer MST 624/634
2 Pages
-
Data Sheet MST 624/634
5 Pages
-
Instruction M/MS 624/634
2 Pages
-
Flyer M/MS 624/634
2 Pages
-
Data Sheet M/MS 624/634
6 Pages
-
Instruction ISP/ISPT 474
2 Pages
-
Flyer ISP/ISPT 474
2 Pages
-
Data Sheet ISP/ISPT 474
6 Pages
-
Instruction ISN/ISNT 471/472
2 Pages
-
Flyer ISN/ISNT 471/472
2 Pages
-
Data Sheet ISN/ISNT 471/472
6 Pages
-
Instruction EXAS 409/419
12 Pages
-
Flyer EXAS 409/419
2 Pages
-
Data Sheet EXAS 409/419
5 Pages
-
Instruction IA/IAS 409/419
2 Pages
-
Flyer IA/IAS 409/419
2 Pages
-
Data Sheet IA/IAS 409/419
5 Pages
-
Instruction EXS 404/414
12 Pages
-
Flyer EXS 404/414
2 Pages
-
Data Sheet EXS 404/414
6 Pages
-
Instruction I/IS 404/414
2 Pages
-
Flyer I/IS 404/414
2 Pages
-
Data Sheet I/IS 404/414
6 Pages
-
Instruction ADS 319
2 Pages
-
Flyer ADS 319
2 Pages
-
Data Sheet ADS 319
5 Pages
-
Instruction D...R 302
2 Pages
-
Flyer D...R 302
2 Pages
-
Data Sheet D...R 302
5 Pages
-
Instruction A2/A2S 198/199
2 Pages
-
Flyer A2/A2S 198/199
2 Pages
-
Data Sheet A2/A2S 198/199
5 Pages
-
Instruction M2S 104/114
2 Pages
-
Flyer M2S 104/114
2 Pages
-
Data Sheet M2S 104/114
6 Pages
-
Potentially hazardous areas EX
12 Pages
-
SF6 Gas Density Monitoring
12 Pages
-
Trafag Insight Brochure
20 Pages
-
Trafag Products Catalogue 2016
161 Pages