Group: sensors & controls
Catalog excerpts
RAILWAY PRESSURETRANSMITTER Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of pressure and temperature. The pressure transmitter NAR 8258 with increased accuracy of 0.3 % was specifically designed for railway vehicles (EN 50155) and has a long-term stable thin-film-on-steel sensor cell. The wide temperature range from -40°C to +125°C and the triple overpressure protection make the NAR 8258 the ideal choice for railway vehicles in rough environmental conditions. Features ■ measuring accuracy 0.3 % ■ Optional: switching output 1 or 2 PNP transistors ■ excellent long-term stability ■ Dielectrical strength: 710 VDC, meets EN 50155 (Railways) subject to change Data sheet H72307 a 05/2017 Trafag Sensors & Controls Industriestrasse 11 sensors controls
Open the catalog to page 1Ordering information/type code Female electrical plug M 12x1,5-pole 2) 33 Output signal Female electrical connector industrial standard (for electrical connection 01) Parameterisation according to customer specification (see table parameter), for output signal PS, T1 ZC 1) Customized pressure ranges upon request 2) For electrical connections 32 and 35 3) Only with electrical connection 32 4) max. allowable pressure range 60 bar at 120 bar overpressure 5) max. allowable pressure range 160 bar at 500 bar overpressure 6) Only for pressure connections 17, 30, 32 7) According to norm...
Open the catalog to page 2trofaq sensors ^^controls
Open the catalog to page 311 See electrical connection 2) Surge voltage on shield, shield connected on both sides trofaq sensors ^^controls
Open the catalog to page 4Measuring accuracy trofaq sensors ^^controls
Open the catalog to page 511 in Category 3 the 2010 versions' higher severity levels apply in each case 2) Chapter 5.1 Voltage supply trofaq sensors ^^controls
Open the catalog to page 6NAR 8258 Electrical connection Protection / electrical connection IP65 *) **) Industrial standard Contact distance 9.4 mm Output signal 8258.xx.xxxx.xx.PS/T1 *) Provided female connector is mounted according to instructions **) Ventilation via male electric plug/cable end 4...20mA: min./max resistor vs. supply voltage @ Pmax = 100% 1200 Customer Load Resistor (Ohm) Rmax Rmin 100°C Rmin 125°C Connection of loads to switching output Customer Supply Voltage (V)
Open the catalog to page 8Functions switching output r Additional information trofaq sensors ^^controls
Open the catalog to page 9All Trafag AG sensors & controls catalogs and technical brochures
-
Pressostat P/PS 900/904/912
6 Pages
-
Pressostat PK 944/947
6 Pages
-
Pressostat 987/988
5 Pages
-
PICOSTAT PST4 9B4
5 Pages
-
8212/13 NAVI-MINITRAG H
4 Pages
-
8822 PRESSURE TRANSDUCER
4 Pages
-
PICOTRANS NPN 8264
6 Pages
-
PRESSURE TRANSMITTER NAH 8254
13 Pages
-
Flush Membrane Transmitter
5 Pages
-
Trafag AG: Temperature monitoring
175 Pages
-
TMT502
4 Pages
-
Navitrag
4 Pages
-
Sensor Master Interface
2 Pages
-
Potentially hazardous areas
12 Pages
-
Hydraulics
24 Pages
-
8100 navitrag T
4 Pages
-
TMP301
10 Pages
-
TMP203
5 Pages
-
Railway Technology
2 Pages
-
Railway vehicles
20 Pages
-
Shipbuilding
16 Pages
-
H70696a_EN_CAN2USB_Tool
2 Pages
-
H70677i_EN_8202_N_Navitrag
2 Pages
-
H70650a
4 Pages
-
H70649a
4 Pages
-
H70636e_EN_878X_Hybrid_GDM
4 Pages
-
H70603a
2 Pages
-
H70600
2 Pages
-
H72302
5 Pages
-
H72304
9 Pages
-
H72303
10 Pages
-
H72207
4 Pages
-
H72206
4 Pages
-
H70694
2 Pages
-
H72335
4 Pages
-
H70697
2 Pages
-
Data Sheet 900/904/912
5 Pages
-
Instruction ECTN 8477
2 Pages
-
Instruction EPI 8287
2 Pages
-
Instruction PST4M 9M4
2 Pages
-
Instruction PST4K 9K4
2 Pages
-
Instruction PSTD 9D0
2 Pages
-
Instruction PST4 9B4
2 Pages
-
Instruction PST4B 9B4
2 Pages
-
Flyer EXPK 944/947/953
2 Pages
-
Data Sheet EXPK 944/947/953
6 Pages
-
Instruction PK 944/947
2 Pages
-
Flyer EXPD 920/924/932
2 Pages
-
Data Sheet EXPD 920/924/932
5 Pages
-
Instruction PD 920/924/932
2 Pages
-
Flyer EXP 900/904/912
2 Pages
-
Data Sheet EXP 900/904/912
5 Pages
-
Instruction P/PS 900/904/912
2 Pages
-
Flyer P/PS 900/904/912
2 Pages
-
Instruction DCS 8864
4 Pages
-
Flyer DCS 8864
2 Pages
-
Data Sheet DCS 8864
5 Pages
-
Instruction EXNA 8854
4 Pages
-
Flyer EXNA 8854
2 Pages
-
Instruction EXNA 8852/8853
4 Pages
-
Flyer EXNA 8852/8853
2 Pages
-
Flyer NAP 8842/8843
2 Pages
-
Data Sheet NAP 8842/8843
6 Pages
-
Flyer NAL 8838
2 Pages
-
Instruction ECON 8498
2 Pages
-
Flyer ECON 8498
2 Pages
-
Data Sheet ECON 8498
4 Pages
-
Instruction ECT 8472
2 Pages
-
Flyer ECT 8472
2 Pages
-
Instruction ECTR 8471
2 Pages
-
Flyer ECTR 8471
2 Pages
-
Data Sheet ECTR 8471
6 Pages
-
Instruction ECL 8438
2 Pages
-
Flyer ECL 8438
2 Pages
-
Instruction EXL 8432
2 Pages
-
Flyer EXL 8432
2 Pages
-
Instruction EPN-S 8320
2 Pages
-
Flyer EPN-S 8320
2 Pages
-
Instruction EPN/EPNCR 8298
2 Pages
-
Flyer EPN/EPNCR 8298
2 Pages
-
Instruction EPI 8297
2 Pages
-
Flyer EPI 8297
2 Pages
-
Data Sheet EPI 8297
4 Pages
-
Instruction EPR 8293
2 Pages
-
Flyer EPR 8293
2 Pages
-
Instruction EXNT 8292
2 Pages
-
Flyer EXNT 8292
2 Pages
-
Instruction CMP 8270
2 Pages
-
Flyer CMP 8270
2 Pages
-
Instruction NPN 8264
2 Pages
-
Flyer NPN 8264
2 Pages
-
Data Sheet NPN 8264
6 Pages
-
Instruction NSL 8257
2 Pages
-
Flyer NSL 8257
2 Pages
-
Instruction NAE 8256
2 Pages
-
Flyer NAE 8256
2 Pages
-
Instruction NAE 8255
2 Pages
-
Flyer NAE 8255
2 Pages
-
Data Sheet NAE 8255
5 Pages
-
Instruction NAH 8254
2 Pages
-
Instruction NAH 8253
2 Pages
-
Flyer NAH 8253
2 Pages
-
Instruction NAT 8252
2 Pages
-
Instruction FPT 8235
2 Pages
-
Flyer FPT 8235
2 Pages
-
Data Sheet FPT 8235
5 Pages
-
Instruction ND 8204
2 Pages
-
Flyer ND 8204
2 Pages
-
Data Sheet ND 8204
4 Pages
-
Instruction N 8202
2 Pages
-
Flyer N 8202
2 Pages
-
Data Sheet N 8202
4 Pages
-
Instruction L...R 755
2 Pages
-
Flyer L...R 755
2 Pages
-
Data Sheet L...R 755
5 Pages
-
Instruction L/LF 736/754
2 Pages
-
Flyer L/LF 736/754
2 Pages
-
Data Sheet L/LF 736/754
5 Pages
-
Instruction MP/MSP 663/664
2 Pages
-
Flyer MP/MSP 663/664
2 Pages
-
Data Sheet MP/MSP 663/664
5 Pages
-
Instruction GS 657/658
2 Pages
-
Flyer GS 657/658
2 Pages
-
Data Sheet GS 657/658
5 Pages
-
Instruction A/AS/ASE 645/650
2 Pages
-
Flyer A/AS/ASE 645/650
2 Pages
-
Data Sheet A/AS/ASE 645/650
5 Pages
-
Instruction MS...R 630/632
2 Pages
-
Flyer MS...R 630/632
2 Pages
-
Data Sheet MS...R 630/632
5 Pages
-
Instruction MSK 624/634
2 Pages
-
Flyer MSK 624/634
2 Pages
-
Data Sheet MSK 624/634
5 Pages
-
Instruction MST 624/634
2 Pages
-
Flyer MST 624/634
2 Pages
-
Data Sheet MST 624/634
5 Pages
-
Instruction M/MS 624/634
2 Pages
-
Flyer M/MS 624/634
2 Pages
-
Data Sheet M/MS 624/634
6 Pages
-
Instruction ISP/ISPT 474
2 Pages
-
Flyer ISP/ISPT 474
2 Pages
-
Data Sheet ISP/ISPT 474
6 Pages
-
Instruction ISN/ISNT 471/472
2 Pages
-
Flyer ISN/ISNT 471/472
2 Pages
-
Data Sheet ISN/ISNT 471/472
6 Pages
-
Instruction EXAS 409/419
12 Pages
-
Flyer EXAS 409/419
2 Pages
-
Data Sheet EXAS 409/419
5 Pages
-
Instruction IA/IAS 409/419
2 Pages
-
Flyer IA/IAS 409/419
2 Pages
-
Data Sheet IA/IAS 409/419
5 Pages
-
Instruction EXS 404/414
12 Pages
-
Flyer EXS 404/414
2 Pages
-
Data Sheet EXS 404/414
6 Pages
-
Instruction I/IS 404/414
2 Pages
-
Flyer I/IS 404/414
2 Pages
-
Data Sheet I/IS 404/414
6 Pages
-
Instruction ADS 319
2 Pages
-
Flyer ADS 319
2 Pages
-
Data Sheet ADS 319
5 Pages
-
Instruction D...R 302
2 Pages
-
Flyer D...R 302
2 Pages
-
Data Sheet D...R 302
5 Pages
-
Instruction A2/A2S 198/199
2 Pages
-
Flyer A2/A2S 198/199
2 Pages
-
Data Sheet A2/A2S 198/199
5 Pages
-
Instruction M2S 104/114
2 Pages
-
Flyer M2S 104/114
2 Pages
-
Data Sheet M2S 104/114
6 Pages
-
Potentially hazardous areas EX
12 Pages
-
SF6 Gas Density Monitoring
12 Pages
-
Trafag Insight Brochure
20 Pages
-
Trafag Products Catalogue 2016