Data Sheet M2S 104/114
6Pages

{{requestButtons}}

Catalog excerpts

Data Sheet M2S 104/114 - 1

Machine tools HVAC Refrigeration Process technology With 1 adjustable step between 2 stages Short response time Protection IP54 Electrical connection on terminal screw Technical Data Designation of application Multistage thermostat with remote sensor Switching differential Measuring range Output signal Floating change-over contact Trafag Sensors & Controls Switzerland www.trafag.com trafag@trafag.com Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for the measurement of pressure and temperature.

Open the catalog to page 1
Data Sheet M2S 104/114 - 2

M2S 104/114 Ordering information/type code XXX XX XX XXX XX XXXXXXXXX XX XX Custom build code External adjustment Internal adjustment Small switching differential, not adjustable Average switching differential, not adjustable With gold plated contacts, not adjustable Sensor diameter Sensor material [mm] Sensor diameter Sensor material [mm] Ø4.7 Copper Stainless steel Stainless steel Stainless steel Copper Copper nickel plated Copper nickel plated Copper nickel plated Copper nickel plated Copper nickel plated Copper nickel plated Copper nickel plated Copper nickel plated Copper nickel plated...

Open the catalog to page 2
Data Sheet M2S 104/114 - 3

Signal lamp Switchpoint fixed and sealed upon customer’s request 4) Switchpoint preset upon customer’s request, no guarantee on switching accuracy 4) Switchpoint adjustment please indicate when ordering: - Switchpoint [bar] - Increasing or decreasing Condensator over Pin 1-2 Outdoor usage (aerated) Capillary tube protection: Flexible metal tube, brass nickel plated Capillary tube protection: Flexible metal tube 1.4541/V2A Capillary tube protection: PVC tube Capillary tube length Capillary tube length up to 5000 mm (no specification required for direct mounting on protection tube) L=XXXX...

Open the catalog to page 3
Data Sheet M2S 104/114 - 4

Temperature compensated with bimetal switch lever Ambient temperature Range ≤ +45°C: -30°C ... +50°C Range +45°C ... +250°C: -30°C ... +70°C Range > + 250°C: -10°C ... +70°C (Important: Temperature at sensor may not exceed maximum sensortemperature) Storage temperature Sensor housing Screwed cable gland Dielectric strength Life time (mechanical) Microswitch 10/11: 20 Mio. cycles Microswitch 21: 0.5 Mio. cycles Cable gland Terminal screw Electrical connection Switching point Switching differential Mechanical Data Environmental conditions Additional information Documents Data sheet...

Open the catalog to page 4
Data Sheet M2S 104/114 - 5

Electrical connection ​ Stage adjustable

Open the catalog to page 5
Data Sheet M2S 104/114 - 6

M2S 104/114 Switching differential typ. Range Microswitch 10 Switching differential (fixed value, not adjustable) Microswitch 11 Switching differential (fixed value, not adjustable) Microswitch 21 Switching differential (fixed value, not adjustable) Steps between stages from switch S2 to switch S1 (S1 on scale): S1 > S2 Steps between stages from switch S2 to switch S1 (S1 on scale): S1 < S2 Microswitch 10 Switching differential (fixed value, not adjustable) Microswitch 11 Switching differential (fixed value, not adjustable) Microswitch 21 Switching differential (fixed value, not adjustable)...

Open the catalog to page 6

All Trafag AG sensors & controls catalogs and technical brochures

  1. TMT502

    4 Pages

  2. Navitrag

    4 Pages

  3. Hydraulics

    24 Pages

  4. TMP301

    10 Pages

  5. TMP203

    5 Pages

  6. Shipbuilding

    16 Pages

  7. H70650a

    4 Pages

  8. H70649a

    4 Pages

  9. H70603a

    2 Pages

  10. H70600

    2 Pages

  11. H72302

    5 Pages

  12. H72304

    9 Pages

  13. H72303

    10 Pages

  14. H72207

    4 Pages

  15. H72206

    4 Pages

  16. H70694

    2 Pages

  17. H72335

    4 Pages

  18. H70697

    2 Pages

  19. H72307

    9 Pages

  20. Flyer N 8202

    2 Pages