@ctiveIO Automation - rugged and dynamic
20Pages

{{requestButtons}}

Catalog excerpts

@ctiveIO Automation - rugged and dynamic - 1

Automating – Robust & Dynamic @activeIO

Open the catalog to page 1
@ctiveIO Automation - rugged and dynamic - 2

Industrial-PC _ VPC/EPC/MIPC - Industrial PC for progressive control engineering _ User-Interface visualization SPC - Slot-SPS _ Central control _ Fieldbus master _ PCI-Slot _ Standard PC-Interfaces @activeIO _ Fieldbus based automation system with decentralized intelligence _ Fieldbus-ready _ Standard sensors and actuators

Open the catalog to page 2
@ctiveIO Automation - rugged and dynamic - 3

@activeIO The system There are two basic series to choose from that fit into the industrial environment. First, the @Control module with © Modules sideways attached for flexible setup; and second, the @Box module where @X modules are inserted for extreme robust applications with higher shock and vibration resistance. There are three performance classes that offer scalable power according to the application: the ^Controller 80C165, the Net-ARM-Prozessor with TCP/IP-Stack onboard and the PC core. @Print @Print The ©Prints are the determining I/O components. A conglomeration of ©Prints build...

Open the catalog to page 3
@ctiveIO Automation - rugged and dynamic - 4

E/A-Module Our variety of I/O modules is as big as the world of automation. Two submodules (@Print) are put together to make one module (@Module). Therefore, different forms of signals can be combined in one module. One controller typically provides up to 20 sub-modules (equals 10 fully equipped modules) with data. The supply voltage for the I/O will be supplied separately to each submodule; therefore, the digital and analog I/O are galvanically separated from the signal processing. Housing Due to various requirements in logistics and modularity, we provide @ctiveIO in two basic housing...

Open the catalog to page 4
@ctiveIO Automation - rugged and dynamic - 5

Controller The @C controllers are the head of the @ctiveIO system. They establish the connection to superior systems via fieldbus or ethernet and communicate with the attached I/O modules. Further, they have the technology function as a controller algorithm, cam controller. @C100 These controllers bring all of the I/O data to the bus. @C101 Fieldbus node with an enhanced storage area for technology functions. @C200 Industrial Ethernet onboard. No matter how your version of the Industrial Ethernet is laid out, with the @C200 you also will have the option of fieldbus and ethernet. @C201, 202,...

Open the catalog to page 5
@ctiveIO Automation - rugged and dynamic - 6

RU N A CT LINK DIAG SP ERR COLL The fieldbus nodes with C165 µController and RS232 interfaces are for diagnoses via @ctiveIO Toolkit. @C5 – Modular platform with high processing power Fieldbus node with ethernet – @C2 The Ethernet controller opens up a connection to Industrial Ethernet. There is standardized transfer of programs into the controller via Ftp (File Transfer Protocol) and the IP address allocation is implemented via the @ctiveIO Toolkit. You can displace alarm signals over an external modem via FTP, URL, UMP or PPP. The DIN rail mounted PC @C500 has a similar modularity as our...

Open the catalog to page 6
@ctiveIO Automation - rugged and dynamic - 7

Fieldbus node @C1_ product Storage – standard _ Flash _ SRAM _ NVRAM 1 MByte (16 Bits) 512 kByte (16 Bits) 1 MByte (16 Bits) 1 MByte (16 Bits) 32 kByte (8 Bits) Power supply Classification _ CANopen _ FiberOptic IIO _ Profibus DP _ DeviceNet _ Ethernet Fieldbus node to connect the I/O with the fieldbus Fieldbus node for technology functions as @PLC Storage – enhanced _ RTC _ SRAM weblink QR-Code Can‘t find the right variant? Please contact us (info@tr-electronic

Open the catalog to page 7
@ctiveIO Automation - rugged and dynamic - 8

Fieldbus node @C1_ product @ctive IO RU N A CT LINK DIAG SP ERR COLL RU N A CT LINK DIAG SP ERR COLL RU N A CT LINK DIAG SP ERR COLL Storage – standard _ Flash _ SRAM _ NVRAM 2 MByte (16 Bits) 8 MByte (32 Bits) 2 MByte (16 Bits) 8 MByte (32 Bits) 32 kByte (8 Bits) 4 MByte (16 Bits) 8 MByte (32 Bits) 32 kByte (8 Bits) × 512 kByte (16 Bits) im Co-Prozessor Power supply Classification _ CANopen _ FiberOptic IIO _ Profibus DP _ DeviceNet _ Ethernet Fieldbus node to connect the I/O with the fieldbus and/or ethernet Fieldbus node for technology functions as @PLC Fieldbus node for technology...

Open the catalog to page 8
@ctiveIO Automation - rugged and dynamic - 9

DIN rail mounted PC -Configuration @C5_ series product Processor _standard _optional Drives _standard _optional Interfaces _standard Power supply _Standard _auf Anfrage 24 VDC, ±20% UPS, other power supply voltage Versorgungsspannung _Moglichkeiten Profibus-DP/FMS combi master, INTERBUS master, CANopen, DeviceNet Master, alternatively as slave Can't find the right variant? Please contact us (info@tr-electronic.de) www.trsystems.de

Open the catalog to page 9
@ctiveIO Automation - rugged and dynamic - 11

Analog Analog input - @P3

Open the catalog to page 11
@ctiveIO Automation - rugged and dynamic - 12

Link x (bis 20)LVDS-Link 10 mSerialized communication @P5 4 12 Serial Interface

Open the catalog to page 12
@ctiveIO Automation - rugged and dynamic - 13

Sensor InterfaceMeasurement system - input @P5

Open the catalog to page 13
@ctiveIO Automation - rugged and dynamic - 14

Condition Monitoring @DIAG Are you interested in the early detection of deterioration and high availability of your system? Then the @DIAG is exactly the right thing for you. The technology module of the @ctiveIO series of TRsystems was developed for the dynamic vibration analysis of industrial machines. You can realize the real time frequency analysis via fast signal processing technology. You can use the advatage of an early-warning system to recognize damages of the roller bearing. Detect plant damages when they emerge. @ctive IO RUN ACT LINK DIAG SP ERR COLL _ capture impact sound based...

Open the catalog to page 14
@ctiveIO Automation - rugged and dynamic - 15

@PLC Modular decentralized allocation of intelligence is key to flexible machine conception as it is required more and more on the market. @PLC is our answer to this challenge. It does appear as a fieldbus node, but the @PLC does hard work in the field at a high-performance level to prepare decentralized signals and to operate independent subprocesses. Therefore, it relieves the master control system and fielbus Machine components can then be built up independently from each other. Another advantage is the standardized programming language IEC-61131 which means continuity throughout your...

Open the catalog to page 15
@ctiveIO Automation - rugged and dynamic - 16

Camshaft Gear @CAM Fast processes need fast signals. The camshaft gear @CAM is able to achieve high performances due to optimized porgramming. @CAM-C203-EN @ctive IO RUN ACT LINK DIAG SP ER R C OLL The @CAM module is a technical software solution to a mechanical camshaft gear. Regardless of whether you are using a distance or positioning measurement system, it simulates up to 255 dynamic cam tracks. There is a total of up to 1024 cams that can be programmed and allocated arbitrarily to the existing 255 cam tracks. For programming, every cam track has a dead time available for increasing and...

Open the catalog to page 16