Catalog excerpts
Large Display Alarm LED’s The 12.5mm LCD display is easy to read, even from a distance. Switch to Set Upper Limit or Set Lower Limit to display and set the control limits. Separate Alarm LED’s for the High and Low Set Points provide visual indication of when the control limits are exceeded. Automatic Control Analogue Outputs Relay Outputs 4 to 20 mA and 0 to 1 V outputs can be userselected and are supplied as standard. A custom 4 to 20 mA output can be factory set, in addition to the usual 4 to 20 mA output for 0 to full scale. The relay outputs are rated to 2 amps at 240 V AC. The limits...
Open the catalog to page 2Specifications and Ordering Information pH Resolution . . . . . . . . . . . . . . . 0.01 pH Accuracy . . . . . . . . . . . . . . +/-0.01 pH Linearity . . . . . . . . . . . . . . +/-0.01 pH Repeatability. . . . . . . . . . . +/-0.01 pH O Ambient Drift . . . . <0.01 pH per 10 C change Resolution . . . . . . . . . . . . . . . . . 1 mV Accuracy . . . . . . . . . . . . . . . . +/-1 mV Linearity . . . . . . . . . . . . . . . . +/-1 mV Repeatability . . . . . . . . . . . . . +/-1 mV O Ambient Drift . . . . . <0.02% span / C Long Term Drift . . . . . <0.1% per year Long Term Drift . . . . . <0.1%...
Open the catalog to page 3Dissolved Oxygen Specifications Specifications Conductivity Specifications Ranges k=0.1 Sensor . . . . . . 0 to 19.99 uS/cm 0 to 199.9 uS/cm 0 to 1999. uS/cm k=1.0 Sensor . . . . . . 0 to 199.9 uS/cm 0 to 1999. uS/cm 0 to 19.99 mS/cm Accuracy. . . . . . . +/-0.2% of full scale k=10 Sensor . . . . . . 0 to 1999. uS/cm 0 to 19.99 mS/cm 0 to 199.9 mS/cm Linearity . . . . . . . . . . . . . . . . +/-0.1% Repeatability . . . . . . . . . . . . . +/-0.2% o Ambient Drift . . . . . . <0.05% span/ C Resolution. . . . . . . . 0.1% of full scale Accuracy. . . . . . . +/-0.2% of full scale Long Term...
Open the catalog to page 4Specifications and Ordering Information Salinity / TDS Dilution Indicator Range . . . . . . . . . . . . . . 0 to 199.9 OC (sensor limit 120 OC) Linearity . . . . . . +/-0.05% of full scale Resolution. . . . . . . . . . . . . . 0.1% D.I. Accuracy. . . . . . . . . . . . . +/-0.1% D.I. Repeatability . . +/-0.05% of full scale O Ambient Drift . . . . . . . . . <0.02% / C Long Term Drift . . . . . <0.1% per year Resolution. . . . . . . . 0.1% of full scale Temperature Compensation Automatic, 0 to 100 OC Accuracy. . . . . . . +/-0.2% of full scale O Resolution . . . . . . . . . . . . . . . . 0.1...
Open the catalog to page 5All TPS catalogs and technical brochures
-
pH Cube
2 Pages
-
labCHEM
4 Pages
-
90-P
4 Pages
-
WP-80
4 Pages
-
WP-91
5 Pages
-
easyCHEM 100
4 Pages
-
General Brochure
6 Pages
-
Hydroponics Products
6 Pages
Archived catalogs
-
pH Cube Benchtop pH Meter
2 Pages