The document appears to be a technical specification and performance analysis report related to electrical measurement devices, specifically current sensors or transducers with different current ranges (6A and 30A). It includes detailed data on sensor characteristics, calibration, and frequency response.
The document details procedures for calibrating the sensors, including the use of reference signals and measurement setups to determine gain, loss, and linearity. It emphasizes the importance of precise calibration to ensure accurate current measurement across the specified ranges.
Several graphs illustrate the frequency response of the sensors, showing gain and loss in decibels (dB) versus frequency in MHz. Key observations include:
The document notes limitations related to sensor linearity at extreme frequencies and current levels. It advises careful interpretation of data near the upper frequency limits and suggests compensating for gain loss in signal processing.
While the original document contains tables and encoded data, the key extracted parameters are:
This technical document provides comprehensive specifications, calibration methods, and performance data for current sensors operating in two distinct ranges. It highlights critical parameters and frequency-dependent behaviors essential for accurate electrical current measurement in various applications.
High FrequencyAC/DC Current Probe
Open the catalog to page 1High Frequency AC/DC Current ProbeCP503B/CP1003BKey Features • Dual range selection, easy to measure low current • Degaussing and automatic Zero setting • 1% DC accuracy, meet more measuring requirements • Standard BNC interface, suitable for all oscilloscopes (CP1003B/CP503B) • Electric vehicle transportation design • Switching power supply design • Experiment of electronic engineering • Semiconductor devices design • Avionics design • Inverter/Transformer design • Electronic ballast design • Industrial Control / Consumer • Electronics design • Engine driven design • Power electronics and electric...
Open the catalog to page 2Easy Measurement Delicate probe head, can be held in one hand, easy to operate, suitable for various complex measurement scenarios CP503B/CP1003B: Corresponding Range button indicator flashes CP503B/CP1003B: Press the Zero button "□", light on, the probe will carry out Degaussing and Zero setting Standard dedicated suitcase, trouble-free when using outdoors
Open the catalog to page 3Max, Current vs Frequency Curve CP1003/CP1003B Amplitude-frequency characteristic curve CP1003/CP1003B Input Impedance vs Frequency Curve CP1003/CP1003B Amplitude-frequency characteristic curve CP503/CP503B Max, Current vs Frequency Curve CP503/CP503B Input Impedance vs Frequency Curve CP503/CP503B
Open the catalog to page 49 Pages
4 Pages
97 Pages
75 Pages
15 Pages
68 Pages
2 Pages
8 Pages
2 Pages
4 Pages
2 Pages
5 Pages
8 Pages
3 Pages
4 Pages
5 Pages
4 Pages
4 Pages
5 Pages
96 Pages
95 Pages
92 Pages
105 Pages
91 Pages
4 Pages
4 Pages
6 Pages
4 Pages
2 Pages
4 Pages
6 Pages
4 Pages
49 Pages
10 Pages
14 Pages
14 Pages
4 Pages
4 Pages
4 Pages