EA-PS 10000 2U

EA-PS 10000 2U
1 / 68 PagesView full catalog

EA-PS 10000 2U

Product catalog summary
General Information
  • Document Usage: The manual should be kept near the equipment for reference and delivered with the equipment if relocated.
  • Copyright: Unauthorized reproduction or use is prohibited.
  • Validity: Applicable to specific EA-PS models.
  • Symbols and Warnings: Symbols indicate dangers and safety notices.
Warranty and Liability
  • Warranty: Covers functional competence and performance from delivery.
  • Limitation of Liability: Manufacturer not liable for misuse or unauthorized modifications.
Disposal
  • Equipment must be returned to the manufacturer for disposal per European regulations.
Product Key
  • Explanation of product description and labeling for identification.
Intended Usage
  • Designed as a variable voltage and current source or sink.
Safety
  • Safety Notices: High voltage risks require specific safety rules.
  • Operator Responsibility: Ensure safety compliance and training.
  • User Requirements: Only qualified individuals should operate the equipment.
Alarm Signals
The device provides alarm signals for non-dangerous conditions, including OverTemperature, OverVoltage, OverCurrent, OverPower, Power Fail, Master-Slave Protection, and Share Bus Fail.
Functionality Test
Operators must decide when to test the device's functionality, involving voltage and current measurements.
Technical Data
Approved Operating Conditions: Operates between 0 °C to 50 °C, stored between -20 °C to 70 °C, and up to 2000 m altitude.
Cooling: Fan cooling with automatic speed adjustment.
General Technical Data
Display: 5” color TFT touch screen.
Controls: Two rotary knobs and one pushbutton.
Specific Technical Data
AC Input: Voltage ranges from 110-127 V and 208-240 V.
DC Output: Specifications for load regulation, line regulation, stability, and temperature coefficient.
Protective Functions: Adjustable protections for overvoltage, overcurrent, overpower, and overtemperature.
Interfaces: USB, Ethernet, and optional interfaces like CAN, RS232, and ModBus TCP.
Device Configuration
Supports parallel operation of up to 64 units with master-slave and share bus systems.
Safety and EMC
Complies with safety and EMC standards.
Environmental Conditions
Operating temperature is 0-50 °C, with storage temperature from -20 to 70 °C.
Mechanical Construction
Cooling through forced air flow, with specified dimensions for different power units.
Technical Specifications
Detailed specifications for various models, including voltage range, ripple, current range, power range, and efficiency.
Control Elements
Control panel includes a touchscreen display, rotary knobs, and an On/Off button for the DC output.
General Description
The PS 10000 2U series DC laboratory power supplies are designed for test systems and industrial applications, featuring a compact 19” enclosure with 2 height units.
Block Diagram
Shows main components and their relationships, including digital, microprocessor-controlled components.
Scope of Delivery
Includes power supply device, remote sensing plugs, USB cable, DC terminal covers, USB stick with documentation and software, and a cable tie.
Accessories and Options
Available accessories include digital interface modules and 19” racks for parallel systems.
Control Panel (HMI)
Features a touchscreen display, rotary knobs, a pushbutton, and a USB port.
USB Ports
Front USB port for data recording and loading profiles; rear USB-B port for device communication and firmware updates.
Interface Module Slot
Accommodates various interface modules for different communication protocols.
Analog Interface
15-pole Sub-D socket for remote control via analog or digital signals.
Share BUS Connector
Allows for parallel operation in master-slave configurations.
Sense Connector
Compensates for voltage drops along DC cables.
Master-Slave Bus
RJ45 sockets enable multiple devices to connect via a digital bus.
Ethernet Port
RJ45 LAN/Ethernet port for device communication.
Remote Control and Monitoring
Offers remote control via HTTP and TCP/IP access, supporting SCPI or ModBus RTU protocols.
Installation & Commissioning
Transport and Storage: Transport horizontally using original packaging.
Unpacking and Visual Check: Inspect for damage before commissioning.
Installation: Ensure proper safety procedures and ventilation.
Connection to AC Supply
Qualified personnel must handle AC connections, ensuring correct voltage and cable cross-section.
Connection to DC Loads
Ensure correct polarity and recommended cable cross-sections.
Remote Sense Connection
Effective during constant voltage operation, requiring proper cable placement.
Grounding
Enclosure and DC output can be grounded for safety.
Interface Module Installation
Optional modules can be retrofitted, following ESD protection procedures.
Connecting Interfaces and Initial Setup
Includes analog interface, Share BUS connectors, USB port, and initial commissioning steps.
Operation and Safety
Only trained personnel should operate the device due to dangerous voltages.
Operating Modes
  • Voltage Regulation (CV): Maintains constant voltage.
  • Current Regulation (CC): Maintains constant current.
  • Power Regulation (CP): Maintains constant power.
  • Internal Resistance Regulation (CR): Simulates a virtual internal resistor.
Alarm Conditions
Includes Power Fail, Overtemperature, Overvoltage Protection, Overcurrent Protection, and Overpower Protection.
Overview: Provides detailed technical specifications and operational procedures for a power supply device.
Specifications: Includes safety Over Voltage Protection and Share bus fail alarm.
Manual Operation: Device is switched on using a toggle switch or external circuit breaker.
Configuration via Menu: Allows configuration of operating parameters and remote control settings.
Communication: Supports digital communication via USB and Ethernet.
Key Features: Emphasizes correct device configuration to prevent unintended operation.
Network Configuration:
Includes IP Address, Subnet Mask, Gateway, DNS, Port, Host Name, and Domain settings.
Profinet/IO Settings:
Customizable settings for Profinet slave.
CAN Bus Settings:
Adjustable baud rate and ID format.
RS232 Settings:
Selectable baud rate with fixed serial settings.
Timeouts and Protocols:
Configurable timeouts and protocol settings.
HMI Setup:
Configurable language, sound, clock, and backlight settings.
Adjustment Limits:
Set values adjustable from 0 to 102%.
Operating Modes:
Switchable modes via knobs or direct input.
DC Output Control:
Manual or remote switching with USB logging support.
USB Logging File Format
Records set and actual values for voltage, current, power, and resistance.
Special Notes and Limitations
Maximum log file size is 4 GB, with up to 1024 log files storable.
Quick Menu
Provides easy access to frequently used features and modes.
The Graph
Displays temporal run of voltage, current, and power values.
Remote Control
Possible via built-in interfaces or optional modules.
Digital Interface Remote Control
Supports various digital interfaces, including CANopen and ModBus TCP.
Analog Interface Remote Control
Allows remote control of current, voltage, power, and internal resistance.
Analog Interface Specification
Includes pins for setting and monitoring values.
Specifications and Resolution:
Outlines specifications of an analog input/output system.
Sub-D Socket Overview:
Provides a simplified diagram of the pins.
Application Examples:
Includes switching the DC output using pin REM-SB.
Device Alarm Handling:
Alarms trigger a DC output switch-off and display a notification.
Locking and User Profiles:
Describes how to lock the control panel and save/load user profiles.
Parallel Operation in Master-Slave Mode:
Multiple devices can be connected in parallel for higher total current and power.
Specifications and Wiring:
Outlines wiring and configuration in a master-slave setup.
Master-Slave Configuration:
Involves setting each unit as either a master or a slave.
Alarms and Problem Situations:
Includes MSP alarms and re-initialization requirements.
Series Connection:
Possible but restricted for safety and isolation reasons.
SEMI F47 Compliance:
Requires devices to continue operating during an AC supply undervoltage.
SEMI F47 Feature: Adjusts maximum power output based on AC input circuit's capacity.
Service and Maintenance: Device requires no regular maintenance, but internal fans may need cleaning.
Troubleshooting: Reversed polarity connection can damage the internal power stage.
Contact and Support: Repairs handled by the manufacturer, with technical support available via email or phone.
See more

Catalog excerpts

EA-PS 10000 2U-1

Programmable DC Power Supplies © EA Elektro-Automatik in 2022, this information is subject to change without notice

 Open the catalog to page 1
EA-PS 10000 2U-2

1.1 About this document 4 1.6.1 Symbols and warnings on the device 6 1.8.1 Approved operating conditions 10 1.8.2 General technical data 10 1.8.3 Specific technical data 11 1.9.7 USB port (rear side) 22 1.9.8 Interface module slot 23 1.9.11 "Sense” connector (remote sensing) 24 2.2 Unpacking and visual check 25 2.3.1 Safety procedures before installation and use 25 2.3.6 Connection of remote sense 30 2.3.8 Installation of an interface module 31 2.3.9 Connecting the analog interface 32 2.3.11 Connecting the USB port (rear side) 32 2.3.13 Commission after a firmware update or a long 3.2.1 Voltage...

 Open the catalog to page 2
EA-PS 10000 2U-3

3.8 Locking the adjustment limits and user pro 3.9 Loading and saving user profiles 59 3.10.1 Parallel operation in master-slave (MS) 60 4.2 Fault finding / diagnosis / repair 65 4.2.2 Trouble-shooting device problems 66 Attention! The part of this document that deals with the handling of features on the control panel is only valid for devices with firmwares "KE: 3.02”, "HMI: 3.02” and "DR: 1.0.2.20” or higher. © EA Elektro-Automatik in 2022, this information is subject to change without notice

 Open the catalog to page 3
EA-PS 10000 2U-4

This document is to be kept in the vicinity of the equipment for future reference and explanation of the operation of the device. This document is to be delivered and kept with the equipment in case of change of location and/or user. The most recent issue of this document can be found online, on our website. Reprinting, copying, also partially, usage for other purposes as foreseen of this manual are forbidden and breach may lead to legal process. This manual is valid for the following equipment including derived variants: EA Elektro-Automatik guarantees the functional competence of the applied...

 Open the catalog to page 4
EA-PS 10000 2U-5

A piece of equipment which is intended for disposal must, according to European laws and regulations (ElektroG, WEEE) be returned to the manufacturer for scrapping, unless the person operating the piece of equipment or another, delegated person is conducting the disposal. Our equipment falls under these regulations and is accordingly marked with the following symbol: The device contains a Lithium battery cell. Disposal of that battery follows the above stated rule or specific local regulations. Decoding of the product description on the label, using an example: © EA Elektro-Automatik in 2022,...

 Open the catalog to page 5
EA-PS 10000 2U-6

The equipment is intended to be used only as a variable voltage and current source or only as a variable current sink. Furthermore it's only intended to be used installed and operated in suitable equipment (19” rack or similar), together with a rigid, non-retractable AC supply connection. Typical application for a voltage source is DC power supply to any relevant user, including when used as battery charger to test charge various battery types, and for current sinks the replacement of an ohmic resistor by an adjustable electronic DC load in order to load relevant voltage and current sources of...

 Open the catalog to page 6
EA-PS 10000 2U-7

• Electrical equipment operation means that some parts accessible on the outside of the device can be under high voltage. Therefore all parts under voltage must be covered during operation! This basically applies to all models, except for the 60 V model according to SELV. • The DC terminal is isolated from the AC input and not connected to ground internally. Hence there can be dangerous potential between the DC poles and PE, for instance caused by a connected external source application. Due to charged capacitors this could even be true if the DC output or the device are already switched off....

 Open the catalog to page 7
EA-PS 10000 2U-8

Operator is any natural or legal person who uses the equipment or delegates the usage to a third party, and is responsible during its usage for the safety of the user, other personnel or third parties. The equipment is in industrial operation. Therefore the operators are governed by the legal safety regulations. Alongside the warning and safety notices in this manual the relevant safety, accident prevention and environmental regulations must also be applied. In particular the operator has to be acquainted with the relevant job safety requirements identify other possible dangers arising from the...

 Open the catalog to page 8
EA-PS 10000 2U-9

The equipment offers various possibilities for signaling alarm conditions, however, not for danger situations. The signals may be optical (on the display as text), acoustic (piezo buzzer) or electronic (status output of the analog interface or digitally readable status bits). All alarms will cause the device to switch off the DC output. For details about the different alarms refer to section "3.3. Alarm conditions". The meaning of the signals is as follows: The operator of the device must decide when to check the device for correct functionality, by whom and how often. The when could either be...

 Open the catalog to page 9
EA-PS 10000 2U-10

Technical data Approved operating conditions Ambiance The allowed ambient temperature range for operation is 0 °C (32 °F) to 50 °C (122 °F). During storage or transport, the allowed range extends to -20 °C (-4 °F) to 70 °C (158 °F). In case water condensation occurred due to transport, the device must be acclimatized prior to operation for at least 2 hours, ideally in a place with good air circulation. The device is intended to be operation in dry rooms. It must not be exposed or operated to extreme dust, high air humidity, danger of explosion and aggressive chemicals polluting the air. The operating...

 Open the catalog to page 10
EA-PS 10000 2U-11

Specific technical data General specifications AC input Voltage, Phases Range 1: 110 - 127 V, ±10%, 1ph AC (with DC output power derating to 1.2 kW or 1.5 kW) Range 2: 208 - 240 V, ±10%, 1ph AC Power factor Leakage current Inrush current Overvoltage category DC output static Load regulation CV ≤0.05% FS (0 - 100% load, constant output voltage and constant temperature) ≤0.01% FS (110 V - 240 V AC +10%, constant load and constant temperature) ≤0.02% FS (during 8 h of operation, after 30 minutes warm-up, at constant output voltage, load and temperature) ≤30ppm/°C (after 30 minutes of warm-up) Compensation...

 Open the catalog to page 11

All TPS Elektronik GmbH catalogs and technical brochures

  1. TO Series

    9  Pages

  2. EA-PSI 10000 4U

    97  Pages

  3. EA-PS 100004U

    75  Pages

  4. TPS-MPT36S

    2  Pages

  5. ESD Trolley

    2  Pages

  6. EA-ELR 10000 4U

    96  Pages

  7. EA-ELR 10000 3U

    95  Pages

  8. EA-PSI 10000 2U

    92  Pages

  9. EA-PSB 10000 2U

    105  Pages

  10. EA-ELR 10000 2U

    91  Pages

  11. EA-PS 9000 1U

    4  Pages

  12. EA-PS 2000 B

    4  Pages

  13. EA-PS 3000C

    4  Pages

  14. HYT-1500360E

    6  Pages

  15. FSP550-50FS

    49  Pages

  16. FSP220-50FGBBI

    10  Pages

  17. FSP300-50UCB

    14  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.