EA-PS 10000 2U
1 /68Pages

EA-PS 10000 2U

EA-PS 10000 2U
1 /68Pages

Catalog excerpts

EA-PS 10000 2U-1

Programmable DC Power Supplies © EA Elektro-Automatik in 2022, this information is subject to change without notice

 Open the catalog to page 1
EA-PS 10000 2U-2

1.1 About this document 4 1.6.1 Symbols and warnings on the device 6 1.8.1 Approved operating conditions 10 1.8.2 General technical data 10 1.8.3 Specific technical data 11 1.9.7 USB port (rear side) 22 1.9.8 Interface module slot 23 1.9.11 "Sense” connector (remote sensing) 24 2.2 Unpacking and visual check 25 2.3.1 Safety procedures before installation and use 25 2.3.6 Connection of remote sense 30 2.3.8 Installation of an interface module 31 2.3.9 Connecting the analog interface 32 2.3.11 Connecting the USB port (rear side) 32 2.3.13 Commission after a firmware update or a long 3.2.1 Voltage...

 Open the catalog to page 2
EA-PS 10000 2U-3

3.8 Locking the adjustment limits and user pro 3.9 Loading and saving user profiles 59 3.10.1 Parallel operation in master-slave (MS) 60 4.2 Fault finding / diagnosis / repair 65 4.2.2 Trouble-shooting device problems 66 Attention! The part of this document that deals with the handling of features on the control panel is only valid for devices with firmwares "KE: 3.02”, "HMI: 3.02” and "DR: 1.0.2.20” or higher. © EA Elektro-Automatik in 2022, this information is subject to change without notice

 Open the catalog to page 3
EA-PS 10000 2U-4

This document is to be kept in the vicinity of the equipment for future reference and explanation of the operation of the device. This document is to be delivered and kept with the equipment in case of change of location and/or user. The most recent issue of this document can be found online, on our website. Reprinting, copying, also partially, usage for other purposes as foreseen of this manual are forbidden and breach may lead to legal process. This manual is valid for the following equipment including derived variants: EA Elektro-Automatik guarantees the functional competence of the applied...

 Open the catalog to page 4
EA-PS 10000 2U-5

A piece of equipment which is intended for disposal must, according to European laws and regulations (ElektroG, WEEE) be returned to the manufacturer for scrapping, unless the person operating the piece of equipment or another, delegated person is conducting the disposal. Our equipment falls under these regulations and is accordingly marked with the following symbol: The device contains a Lithium battery cell. Disposal of that battery follows the above stated rule or specific local regulations. Decoding of the product description on the label, using an example: © EA Elektro-Automatik in 2022,...

 Open the catalog to page 5
EA-PS 10000 2U-6

The equipment is intended to be used only as a variable voltage and current source or only as a variable current sink. Furthermore it's only intended to be used installed and operated in suitable equipment (19” rack or similar), together with a rigid, non-retractable AC supply connection. Typical application for a voltage source is DC power supply to any relevant user, including when used as battery charger to test charge various battery types, and for current sinks the replacement of an ohmic resistor by an adjustable electronic DC load in order to load relevant voltage and current sources of...

 Open the catalog to page 6
EA-PS 10000 2U-7

• Electrical equipment operation means that some parts accessible on the outside of the device can be under high voltage. Therefore all parts under voltage must be covered during operation! This basically applies to all models, except for the 60 V model according to SELV. • The DC terminal is isolated from the AC input and not connected to ground internally. Hence there can be dangerous potential between the DC poles and PE, for instance caused by a connected external source application. Due to charged capacitors this could even be true if the DC output or the device are already switched off....

 Open the catalog to page 7
EA-PS 10000 2U-8

Operator is any natural or legal person who uses the equipment or delegates the usage to a third party, and is responsible during its usage for the safety of the user, other personnel or third parties. The equipment is in industrial operation. Therefore the operators are governed by the legal safety regulations. Alongside the warning and safety notices in this manual the relevant safety, accident prevention and environmental regulations must also be applied. In particular the operator has to be acquainted with the relevant job safety requirements identify other possible dangers arising from the...

 Open the catalog to page 8
EA-PS 10000 2U-9

The equipment offers various possibilities for signaling alarm conditions, however, not for danger situations. The signals may be optical (on the display as text), acoustic (piezo buzzer) or electronic (status output of the analog interface or digitally readable status bits). All alarms will cause the device to switch off the DC output. For details about the different alarms refer to section "3.3. Alarm conditions". The meaning of the signals is as follows: The operator of the device must decide when to check the device for correct functionality, by whom and how often. The when could either be...

 Open the catalog to page 9
EA-PS 10000 2U-10

Technical data Approved operating conditions Ambiance The allowed ambient temperature range for operation is 0 °C (32 °F) to 50 °C (122 °F). During storage or transport, the allowed range extends to -20 °C (-4 °F) to 70 °C (158 °F). In case water condensation occurred due to transport, the device must be acclimatized prior to operation for at least 2 hours, ideally in a place with good air circulation. The device is intended to be operation in dry rooms. It must not be exposed or operated to extreme dust, high air humidity, danger of explosion and aggressive chemicals polluting the air. The operating...

 Open the catalog to page 10
EA-PS 10000 2U-11

Specific technical data General specifications AC input Voltage, Phases Range 1: 110 - 127 V, ±10%, 1ph AC (with DC output power derating to 1.2 kW or 1.5 kW) Range 2: 208 - 240 V, ±10%, 1ph AC Power factor Leakage current Inrush current Overvoltage category DC output static Load regulation CV ≤0.05% FS (0 - 100% load, constant output voltage and constant temperature) ≤0.01% FS (110 V - 240 V AC +10%, constant load and constant temperature) ≤0.02% FS (during 8 h of operation, after 30 minutes warm-up, at constant output voltage, load and temperature) ≤30ppm/°C (after 30 minutes of warm-up) Compensation...

 Open the catalog to page 11

All TPS Elektronik GmbH catalogs and technical brochures

  1. TO Series

    9  Pages

  2. EA-PSI 10000 4U

    97  Pages

  3. EA-PS 100004U

    75  Pages

  4. TPS-MPT36S

    2  Pages

  5. ESD Trolley

    2  Pages

  6. EA-ELR 10000 4U

    96  Pages

  7. EA-ELR 10000 3U

    95  Pages

  8. EA-PSI 10000 2U

    92  Pages

  9. EA-PSB 10000 2U

    105  Pages

  10. EA-ELR 10000 2U

    91  Pages

  11. EA-PS 9000 1U

    4  Pages

  12. EA-PS 2000 B

    4  Pages

  13. EA-PS 3000C

    4  Pages

  14. HYT-1500360E

    6  Pages

  15. FSP550-50FS

    49  Pages

  16. FSP220-50FGBBI

    10  Pages

  17. FSP300-50UCB

    14  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.