EA-ELR 10000 4U
1 /96Pages

EA-ELR 10000 4U

EA-ELR 10000 4U
1 /96Pages

Catalog excerpts

EA-ELR 10000 4U-1

EA-ELR 10000 4UProgrammable Electronic DC Loads with Energy Recovery 33200800_manual_elr_10000_4u_30kw_en_03 © EA Elektro-Automatik in 2022, this information is subject to change without notice

 Open the catalog to page 1
EA-ELR 10000 4U-2

1.1 About this document 5 1.1.4 Symbols and warnings in this document 5 1.6.1 Symbols and warnings on the device 7 1.8.1 Approved operating conditions 11 1.8.2 General technical data 11 1.8.3 Specific technical data 12 1.9.7 USB port (rear side) 26 1.9.8 Interface module slot 26 1.9.11 "Sense” connector (remote sensing) 27 2.2 Unpacking and visual check 29 2.3.1 Safety procedures before installation and use 29 2.3.4 Connection to water supply (WC models) 32 2.3.8 Connection of remote sensing 38 2.3.9 Installation of an interface module 39 2.3.10 Connection of the analog interface 40 2.3.12 Connection...

 Open the catalog to page 2
EA-ELR 10000 4U-3

3.5.3 Remote control via a digital interface 59 3.5.4 Remote control via the analog interface 61 3.6.2 Device alarm and event handling 65 3.7 Locking the control panel (HMI) 68 3.8 Locking the adjustment limits and user profiles 68 3.9 Loading and saving user profiles 69 3.10.5 Sine wave function 72 3.10.12 IU table function (XY table) 80 3.10.13 Battery test function 81 3.10.15 Remote control of the function generator 86 3.11.1 Parallel operation in master-slave (MS) 87 4.2 Fault finding / diagnosis / repair 92 4.2.2 Trouble-shooting device problems 93 The part of this document that deals with...

 Open the catalog to page 3
EA-ELR 10000 4U-4

© EA Elektro-Automatik in 2022, this information is subject to change without notice 33200800_manual_elr_10000_4u_30kw_en_03 4

 Open the catalog to page 4
EA-ELR 10000 4U-5

This document is to be kept in the vicinity of the equipment for future reference and explanation of the operation of the device. This document is to be delivered and kept with the equipment in case of change of location and/or user. The most recent issue of this document can be found online, on our website. Modification and partial or complete usage of this PDF document for other purposes as intended are forbidden and breach may lead to legal process. This manual is valid for the following equipment and its variants: 1.1.4 Symbols and warnings in this document Warning and safety notices as well...

 Open the catalog to page 5
EA-ELR 10000 4U-6

A piece of equipment which is intended for disposal must, according to European laws and regulations (ElektroG, WEEE) be returned to the manufacturer for scrapping, unless the person operating the piece of equipment or another, delegated person is conducting the disposal. Our equipment falls under these regulations and is accordingly marked with the following symbol: The device contains a Lithium battery cell. Disposal of that battery follows the above stated rule or specific local regulations. Decoding of the product description on the label, using an example: EA-ELR 10080 - 1000 4U xxx Options...

 Open the catalog to page 6
EA-ELR 10000 4U-7

The equipment is intended to be used only as a variable voltage and current source or only as a variable current sink. Furthermore it's only intended to be used installed and operated in suitable equipment (19” rack or similar), together with a rigid, non-retractable AC supply connection. Typical application for a voltage source is DC power supply to any relevant user, including when used as battery charger to test charge various battery types, and for current sinks the replacement of an ohmic resistor by an adjustable electronic DC load in order to load relevant voltage and current sources of...

 Open the catalog to page 7
EA-ELR 10000 4U-8

Safety notices • Electrical equipment operation means that some parts accessible on the outside of the device can be under high voltage. Therefore all parts under voltage must be covered during operation! This basically applies to all models. • The DC terminal is isolated from the AC input and not connected to ground internally. Hence there can be dangerous potential between the DC poles and PE, for instance caused by a connected external source application. Due to charged capacitors this could even be true if the DC input or the device are already switched off. • Do not insert any object, particularly...

 Open the catalog to page 8
EA-ELR 10000 4U-9

Operator is any natural or legal person who uses the equipment or delegates the usage to a third party, and is responsible during its usage for the safety of the user, other personnel or third parties. The equipment is in industrial operation. Therefore the operators are governed by the legal safety regulations. Alongside the warning and safety notices in this manual the relevant safety, accident prevention and environmental regulations must also be applied. In particular the operator has to • be acquainted with the relevant job safety requirements • identify other possible dangers arising from...

 Open the catalog to page 9
EA-ELR 10000 4U-10

The equipment offers various possibilities for signaling alarm conditions, however, not for danger situations. The signals may be optical (on the display as text or via LED), acoustic (piezo buzzer) or electronic (pin/status output of an analog interface). All alarms will cause the device to switch off the DC input. For details about the different alarms refer to section "3.3. Alarm conditions". The meaning of the signals is as follows: The operator of the device must decide when to check the device for correct functionality, by whom and how often. The when could either be before every use or...

 Open the catalog to page 10
EA-ELR 10000 4U-11

Technical Data Approved operating conditions Ambiance The allowed ambient temperature range for operation is 0 °C (32 °F) to 50 °C (122 °F). During storage or transport, the allowed range extends to -20 °C (-4 °F) to 70 °C (158 °F). In case water condensation occurred due to transport, the device must be acclimatized prior to operation for at least 2 hours, ideally in a place with good air circulation. The device is intended to be operation in dry rooms. It must not be exposed or operated to extreme dust, high air humidity, danger of explosion and aggressive chemicals polluting the air. The operating...

 Open the catalog to page 11
EA-ELR 10000 4U-12

Specific technical data General specifications AC input Voltage, Phases Range 1: 208 V, ±10%, 3ph AC (with DC input power derating to 18 kW) Range 2: 380 - 480 V, ±10%, 3ph AC Power factor Leakage current Inrush current / Phase current Overvoltage category DC input static Load regulation CV ≤0.05% FS (0 - 100% load, constant input voltage and constant temperature) ≤0.01% FS (208 V - 480 V AC +10% input voltage, constant load and constant temperature) ≤0.02% FS (during 8 h of operation, after 30 minutes warm-up, at constant input voltage, load and temperature) ≤30ppm/°C (after 30 minutes of warm-up)...

 Open the catalog to page 12

All TPS Elektronik GmbH catalogs and technical brochures

  1. TO Series

    9  Pages

  2. EA-PSI 10000 4U

    97  Pages

  3. EA-PS 100004U

    75  Pages

  4. EA-PS 10000 2U

    68  Pages

  5. TPS-MPT36S

    2  Pages

  6. ESD Trolley

    2  Pages

  7. EA-ELR 10000 3U

    95  Pages

  8. EA-PSI 10000 2U

    92  Pages

  9. EA-PSB 10000 2U

    105  Pages

  10. EA-ELR 10000 2U

    91  Pages

  11. EA-PS 9000 1U

    4  Pages

  12. EA-PS 2000 B

    4  Pages

  13. EA-PS 3000C

    4  Pages

  14. HYT-1500360E

    6  Pages

  15. FSP550-50FS

    49  Pages

  16. FSP220-50FGBBI

    10  Pages

  17. FSP300-50UCB

    14  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.