1. Catalogs
  2. Toscano Linea Electronica
  3. Catalogue Pump Protection 2015
video corpo

Catalogue Pump Protection 2015

Catalogue Pump Protection 2015
1 / 32 PagesView full catalog

Catalogue Pump Protection 2015

Product catalog summary
Vigilec Pump Control System Overview: The Vigilec pump control system is designed for easy installation and provides advanced protection and control for various types of pumps. It supports dual power supply (230/400 V) and can handle motor currents up to 18 A AC3 with a maximum power rating of 2.2 kW. The system operates within a temperature range of -10º C to +55º C and is protected with an IP56 rating.
Protection Features: The system offers overload, underload, phase failure, overvoltage, dry running, and jammed impeller protection. It is storm-proof, ensuring reliable operation in various conditions.
Control Modes and Applications: Vigilec supports multiple control modes with or without probes, suitable for wells, boreholes, booster pumps, pools, and drainage systems. It supports various sensors and switches for precise control and monitoring.
Installation and Operation: Designed for easy installation with wide cable glands and terminal blocks, it features manual-off-auto push buttons, pilot lights, and an alarm reset button for user convenience.
Advanced Features: Incorporates SMD technology and expertise control systems, ensuring reliability and cost-effectiveness. It complies with international standards.
Pump Control and Protection Units Overview: These units manage multiple pumps with automatic alternation, suitable for single and three-phase pumps with direct-on-line (DOL) starting. They support dual voltage supply (230/400V AC).
Specifications and Functionality: The units handle motor currents up to 12A or 18A AC3, with a maximum power rating of 5.5 kW at 400V AC. They feature adjustable overload protection and underload adjustment, automatic pump alternation, and remote control input.
Protections and Equipment: Equipped with phase failure, overvoltage, overload, and dry running protections. Includes main switch-disconnector, power circuit breakers, and MANUAL-OFF-AUTO push buttons.
Installation and Additional Features: Designed for clevis wall mounting, protected with an IP56 rating, and includes remote control capabilities and a 3-digit LED display for pressure and current value adjustments.
Water Level Control Relays and Remote Control Systems Overview: These systems are essential for maintaining optimal water levels and ensuring efficient pump operations. They include models like TH1, TH2, TH3, TH5, TH6, THZT, and THR with specific features.
Specifications and Procedures: Models offer dual power supply options, adjustable probe sensitivity, and various load contact capacities. Designed for easy installation, they require correct ground connection for effective operation.
Remote Control Systems and Alternation Relays: The THR model features a radio remote water level control system. Alternation relays ensure balanced operating time across pumps.
Recommendations: Ensure proper grounding and adhere to specified voltage and temperature ranges for optimal performance.
TPM2 Motor Protection Relay Overview: Designed for safeguarding motors and pumps against electrical issues. Features dual power supply, dry running protection, and easy current trip adjustment.
Specifications and Functionalities: Includes overload, underload, and phase failure detection, selectable restart options, and LED status indicators. Suitable for both three-phase and single-phase motors.
Additional Features and Accessories: Offers easy current adjustment, environmental independence, and transducer options. Accessories include continuity tester, surge arresters, and pressure and flow sensors.
See more

Catalog excerpts

Catalogue Pump Protection 2015-1

pump controllers water level relays remote level controllers alternation relays motor protectors

 Open the catalog to page 1
Catalogue Pump Protection 2015-2

tOSCanO offers products ttaat give advanced and practical solutions to your installations at competitive prices Otlr aim is to develop and manufacture quality products, easy to install, with the whole technical support and the expcnence of years working togethei with our customers. Thank you for trusting in tOSCanO

 Open the catalog to page 2
Catalogue Pump Protection 2015-3

V igilec. Just to install. Vigilec is more than just a pump panel board, it’s a ready to install pump controller that the market nowdays demands. Dual power supply 230/400 Vca Safety Transformer High-rate Starting Alarm (contact output) Circuit Breaker Multi-Function Remote Control: Voltage (6 to 400 Vac/Vdc) or Voltage-free Contact Overload Adjustment Power Contactor Solenoid valve option Underload Adjustment 3 Modes: - 2 Probes -1 Probe - No Probes Wide Wiring Area Control Terminal Blocks (wrong wiring protection) Pump Running LED Wide range in cable glands DRY RUNNING OVER/UNDER LOAD OVER/UNDER...

 Open the catalog to page 3
Catalogue Pump Protection 2015-4

V igilec. New Times. New Concepts. For Pump Manufacturers and Dealers: • • • • • Greater protection for their pumps. Electronic control of Over/Underload and Phase failure. Advanced control possibilities. Extensive product range. Custom Labelling. Reduction of stock requirements. Only one model dual power supply 230/400 V. Only one model up to 12 amps. Competitive prices. For Installers and Panel Builders: • • • • Easy mounting and adjustment. Advanced control possibilities. Automatic level control without probes. Auto pressure control with no pressure switches. Detection of high frequency starts....

 Open the catalog to page 4
Catalogue Pump Protection 2015-5

V igilec. Just to install. ion tallat : sy Ins Ea aving d ney s o ion an and M stallat in d easy uick an nt.  Q stme adju g. e savin lay: tim P g and glands  Plu t cable pu ut/out ide inp al blocks.  W ermin and t High tech manufacturing process: :  Ex clusiv e feat ures.  Up -date d des ign.  SM D tec hnolo gy.  Ex pertis e con trol s ystem . te  Series production with absolu reliability.  Full operation warranty. y  Scale cost reduction offers ver . attractive prices  Endurance and computer testing.  Expertise standards and application knowledge.  International standards approval....

 Open the catalog to page 5
Catalogue Pump Protection 2015-6

Pump protection & Homeowners safety with Vigilec TURBINE PROTECTION ■ Underload. ■ Dry running. MOTOR PROTECTION ■ Overload. ■ Phase failure, overvoltage. ■ Jammed impeller. ■ Wiring defects. OVERLOAD ■ Vigilec has an accurate motor current control. ■ It can adjust and limit the maximum current. ■ In case of overload the motor will stop in a few secs. ■ It avoids motor overheating. UNDERLOAD ■ Without flow the motor current will be lower, working in these conditions will damage the turbine. ■ Vigilec detects it and shut down the pump. ■ This feature prevents serious pump damage. DRY RUNNING ■...

 Open the catalog to page 6
Catalogue Pump Protection 2015-7

V igilec. Just to install. Vigilec Typical Applications Wells & Boreholes Booster pumps WELLS & BOREHOLES  1 Probe (auto restart on delay).  2 Probes (on-off).  Without probes.  Float & pressure switches / relays / Voltage 24 Vac (irrigation prog.). BOOSTER PUMPS  Pressure switches.  Internal sensor.  External sensor 4-20 mA. POOLS  Time switch.  Dirty filter detection. DRAINAGE & SEWAGE PUMPS  Float switches.  External sensor 4-20 mA.  Air bubbler system. BOOSTER PUMP SETS  Pressure switches.  Internal sensor.  External sensor 4-20 mA. Booster pump sets Drainage & Sewage pumps...

 Open the catalog to page 7
Catalogue Pump Protection 2015-8

NOTE: Extra internal ciruits for further remote signals (start, overload, failure water) etc.

 Open the catalog to page 8
Catalogue Pump Protection 2015-9

ump controllers General use1 Pump_ 1 Single-phase pump control up to 2’2 KW. (direct-on-line starting -DOL-) V1M ■ An all-in-one control and protection unit for any pump. ■ Multicontrol. ■ Single-phase 230 V AC, direct-on-line starting (DOL). ■ Pump wiring failure protection. ■ Overvoltage protection. ■ Overload protection. ■ Underload protection. ■ Connection failures protection warranted. ■ Overvoltage transient protected (Storm-proof). ■ Dry-running protection by 3 configurations. ■ Jammed impeller protection for long resting periods (only in AUTO mode). ■ Alarm for detection of high frequency...

 Open the catalog to page 9
Catalogue Pump Protection 2015-10

iThree/single phase pump control up to 15 KW (direct-on-line starting -DOL-), Multicontrol V1N ■ An all-in-one control and protection unit for any pump. ■ Multicontrol. ■ Three/Single-phase, direct-on-line starting (DOL). ■ Dual voltage supply: 230/400V AC. ■ Phase failure protection. ■ Pump wiring failure protection. ■ Overvoltage protection. ■ Overload protection. ■ Underload protection. ■ Connection failures protection warranted. ■ Overvoltage transient protected (Storm-proof). ■ Dry-running protection by 3 configurations. ■ Protection against jammed impeller for long resting periods (only in...

 Open the catalog to page 10
Catalogue Pump Protection 2015-11

V1N / V10-PLUS DIRECT CURRENT DISPLAY VOLT VOLTAGE TAGE SELECT MODE SELECT V-10 PLUS ADDITIONAL ADVANCES Amp. MAX • Current digital display. • Reset time adjustment. • General alarm output. 230V • Selectable protection against jammed impeller (ON/OFF). • Selectable control mode: - 1 Probe - 2 Probes. - Without probes. WELL & BOREHOLE WELL & BOREHOLE WELL & BOREHOLE DRAINAGE & SEWAGE PROBES MODE FLOAT MODE WITHOUT PROBES MODE

 Open the catalog to page 11
Catalogue Pump Protection 2015-12

2 Single phase pumps control up to 2,2 kW (direct-on-line starting V2M -DOL-), by Pressure switches or Embedded pressure sensor ump controllers Booster sets2 Pumps ■ Control and protection unit for two pumps with automatic alternation, by two pressure switches (V2MP), or embedded sensor (V2MT). ■ Multi-control. ■ Single phase. Direct-on-line starting (DOL). ■ Voltage 230V AC. ■ Overvoltage protection. ■ Overload protection. ■ Overvoltage transient protected (Storm-proof). ■ Dry running protection by built-in water level or float contact. ■ Jammed impeller protection for long resting periods....

 Open the catalog to page 12
Catalogue Pump Protection 2015-13

ump controllers Booster sets2 Pumps 2 Three/single phase pumps control up to 5,5 kW (direct-on-line starting -DOL-), by Pressure switches or embedded Pressure sensor V2 ■ Control and protection unit for two pumps with automatic alternation, by two pressure switches (V2P), or embedded sensor (V2T). ■ Multicontrol. ■ Three/Single-phase, direct-on-line starting (DOL). ■ Dual voltage supply: 230/400V AC. ■ Phase failure protection. ■ Overvoltage protection. ■ Overload protection. ■ Overvoltage transient protector (storm-proof). ■ Dry running protection by built-in water level or float contact. ■...

 Open the catalog to page 13
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.