Vigilec Pump Control System Overview: The Vigilec pump control system is designed for easy installation and provides advanced protection and control for various types of pumps. It supports dual power supply (230/400 V) and can handle motor currents up to 18 A AC3. The system offers overload and underload adjustments, with a reset time of 15 minutes after low current shutdown. It is protected against overvoltage, phase failure, and dry running, with an IP56 protection rating and an operating temperature range of -10º C to +55º C.
Protection and Control Features: Vigilec provides extensive protection for pumps, including overload, underload, phase failure, and jammed impeller protection. It includes a multi-function remote control, manual-auto modes, and various operation modes. The system supports remote control connections and has adjustable electronic relays for overload and underload protection.
Applications and Installation: Suitable for wells, boreholes, booster pumps, pools, and drainage and sewage pumps, Vigilec offers automatic level control without probes and auto pressure control without pressure switches. It is designed for easy installation with wide wiring areas and control terminal blocks, and it is maintenance-free.
Additional Features: The system includes storm-proof protection, high-frequency start detection, and customizable labeling options. It is compliant with international standards and offers competitive pricing.
Pump Control and Protection Units Overview: These units manage multiple pumps with automatic alternation, supporting both pressure switches and embedded sensors. They control pumps up to 5.5 kW with direct-on-line starting and offer phase failure, overvoltage, and overload protection.
Functionality and Protections: The units provide automatic alternation between pumps, start/stop cascade control, and remote control input options. They include dry running protection, jammed impeller protection, and air-break detection in pressure tanks. Comprehensive protection mechanisms include phase failure, overvoltage, overload, and dry running protection.
Equipment and General Features: Each unit is equipped with main switch-disconnectors, power circuit breakers, power contactors, and manual-off-auto push buttons. They are designed for clevis wall mounting and offer IP56 protection.
Water Level Control Relays and Remote Control Systems Overview: These systems are essential for maintaining optimal water levels and ensuring efficient pump operations. The document outlines several models of water level relays with specific features such as dual power supply options and adjustable probe sensitivity.
Procedures and Remote Control Systems: The relays are designed for easy installation, with proper grounding emphasized. The THR model features a radio remote water level control system, and the TAF system allows for reliable signal transmission over long distances.
Alternation Relays and Recommendations: Designed for alternating pump operations, these relays ensure balanced usage and reduce wear. The document recommends using standard alkaline batteries for remote stations without power supply.
Motor Protection Relays Overview: The TPM2 series is designed for overload, underload, and phase failure protection in motors and pumps. It includes technical specifications, operational features, and additional accessories for enhanced motor protection.
Specifications and Additional Features: The relays offer dual power supply, overload, underload, and phase failure detection, and dry running protection. They include LED status indicators, easy current trip adjustment, and auxiliary remote control for start-stop operations.
Applications: The TPM2 series is used for protecting motors and pumps from common issues such as overload, phase loss, phase reversal, and dry running, ensuring longevity and reliability in various industrial applications.
See more

Catalog excerpts

Catalogue Export [English]-1

level relays remote level

 Open the catalog to page 1
Catalogue Export [English]-2

tOSCariO offers products that grve advanced and practical solutions to your installations at competitive prices. Otir aim is to develop and manufacture quality products* easy to install. with the whole technical support and the experience of years working together with our customers. Thank you lor trusting In toscano

 Open the catalog to page 2
Catalogue Export [English]-3

V igilec. Just to install. Vigilec is more than just a pump panel board, it’s a ready to install pump controller that the market nowdays demands. Dual power supply 230/400 Vca Safety Transformer High-rate Starting Alarm (contact output) Circuit Breaker Multi-Function Remote Control: Voltage (6 to 400 Vac/Vdc) or Voltage-free Contact Overload Adjustment Power Contactor Solenoid valve option Underload Adjustment 3 Modes: - 2 Probes -1 Probe - No Probes Wide Wiring Area Control Terminal Blocks (wrong wiring protection) Pump Running LED Wide range in cable glands DRY RUNNING OVER/UNDER LOAD OVER/UNDER...

 Open the catalog to page 3
Catalogue Export [English]-4

V igilec. New Times. New Concepts. For Pump Manufacturers and Dealers: • • • • • Greater protection for their pumps. Electronic control of Over/Underload and Phase failure. Advanced control possibilities. Extensive product range. Custom Labelling. Reduction of stock requirements. Only one model dual power supply 230/400 V. Only one model up to 12 amps. Competitive prices. For Installers and Panel Builders: • • • • Easy mounting and adjustment. Advanced control possibilities. Automatic level control without probes. Auto pressure control with no pressure switches. Detection of high frequency starts....

 Open the catalog to page 4
Catalogue Export [English]-5

V igilec. Just to install. ion tallat : sy Ins Ea aving d ney s o ion an and M stallat in d easy uick an nt. Q stme adju g. e savin lay: tim P g and glands Plu t cable pu ut/out ide inp al blocks. W ermin and t High tech manufacturing process: : Ex clusiv e feat ures. Up -date d des ign. SM D tec hnolo gy. Ex pertis e con trol s ystem . te Series production with absolu reliability. Full operation warranty. y Scale cost reduction offers ver . attractive prices Endurance and computer testing. Expertise standards and application knowledge. International standards approval. ¡¡ Vigilec, the right...

 Open the catalog to page 5
Catalogue Export [English]-6

ijilcC. New Times. New Concepts. imp protection & Homeowners safety with Vigilec TURBINE PROTECTION Phase failure, overvoltage. Jammed impeller. ■ Vigilec has an accurate motor current control. ■ It can adjust and limit the maximum current. ■ In case of overload the motor will stop in a few sees. ■ It avoids motor overheating. ■ Without flow the motor current will be lower, working in these conditions will damage the turbine. ■ Vigilec detects it and shut down the pump. ■ This feature prevents serious pump damage. ■ Pumps can't work in dry running conditions for extended periods. ■ Vigilec will...

 Open the catalog to page 6
Catalogue Export [English]-7

V igilec. Just to install. Vigilec Typical Applications Wells & Boreholes Booster pumps WELLS & BOREHOLES 1 Probe (auto restart on delay). 2 Probes (on-off). Without probes. Float & pressure switches / relays / Voltage 24 Vac (irrigation prog.). BOOSTER PUMPS Pressure switches. Internal sensor. External sensor 4-20 mA. POOLS Time switch. Dirty filter detection. DRAINAGE & SEWAGE PUMPS Float switches. External sensor 4-20 mA. Air bubbler system. BOOSTER PUMP SETS Pressure switches. Internal sensor. External sensor 4-20 mA. Booster pump sets Drainage & Sewage pumps √ All controls and field elements...

 Open the catalog to page 7
Catalogue Export [English]-8

election table & ranges NOTE: Extra internal ciruits for further remote signals (start, overload, failure water) etc.

 Open the catalog to page 8
Catalogue Export [English]-9

1 Single-phase pump control up to 2’2 KW. (direct-on-line starting -DOL-) An all-in-one control and protection unit for any pump. Multicontrol. Single-phase 230 V AC, direct-on-line starting (DOL). Pump wiring failure protection. Overvoltage protection. Overload protection. Underload protection. Connection failures protection warranted. Overvoltage transient protected (Storm-proof). Dry-running protection by 3 configurations. Jammed impeller protection for long resting periods (only in AUTO mode). Alarm for detection of high frequency starts and/or air-break in pressure tank. Operation modes:...

 Open the catalog to page 9
Catalogue Export [English]-10

1Three/single phase pump control up to 15 KW. (direct-on-line starting -DOL-), Multicontrol An all-in-one control and protection unit for any pump. Multicontrol. Three/Single-phase, direct-on-line starting (DOL). Dual voltage supply: 230/400V AC. Phase failure protection. Pump wiring failure protection. Overvoltage protection. Overload protection. Underload protection. Connection failures protection warranted. Overvoltage transient protected (Storm-proof). Dry-running protection by 3 configurations. Protection against jammed impeller for long resting periods (only in AUTO mode). Motor protection...

 Open the catalog to page 10
Catalogue Export [English]-11

V1N / V10-PLUS DIRECT CURRENT DISPLAY VOLT VOLTAGE TAGE SELECT MODE SELECT V-10 PLUS ADDITIONAL ADVANCES Amp. MAX • Current digital display. • Reset time adjustment. • General alarm output. 230V • Selectable protection against jammed impeller (ON/OFF). • Selectable control mode: - 1 Probe - 2 Probes. - Without probes. WELL & BOREHOLE WELL & BOREHOLE WELL & BOREHOLE DRAINAGE & SEWAGE PROBES MODE FLOAT MODE WITHOUT PROBES MODE

 Open the catalog to page 11
Catalogue Export [English]-12

p ump controllers Booster sets 2 Single phase pumps control up to 2,2 kW (direct-on-line starting -DOL-), by Pressure switches or Embedded pressure sensor Control and protection unit for two pumps with automatic alternation, by two pressure switches (V2MP), or embedded sensor (V2MT). Multi-control. Single phase. Direct-on-line starting (DOL). Voltage 230V AC. Overvoltage protection. Overload protection. Overvoltage transient protected (Storm-proof). Dry running protection by built-in water level or float contact. Jammed impeller protection for long resting periods. The unit activates motor for...

 Open the catalog to page 12
Catalogue Export [English]-13

2 Three/single phase pumps control up to 5,5 kW (direct-on-line starting -DOL-), by Pressure switches or embedded Pressure sensor Control and protection unit for two pumps with automatic alternation, by two pressure switches (V2P), or embedded sensor (V2T). Multicontrol. Three/Single-phase, direct-on-line starting (DOL). Dual voltage supply: 230/400V AC. Phase failure protection. Overvoltage protection. Overload protection. Overvoltage transient protector (storm-proof). Dry running protection by built-in water level or float contact. Jammed impeller protection for long resting periods (only in...

 Open the catalog to page 13