T-500 flowmeter series uses the electromagnetic principle to measure the flow of conductive liquids. There is therefore no moving parts in contact with the liquid, so it is not affected by the solid particles that could pass through the pipe, and there is no pressure drop. It is made of carbon steel with a hard rubber lining (PTFE on request), which allows its use in many applications in the chemical industry. It includes a local display of the instantaneous and totalized flow. • High accuracy. • Excellent stability. • Robust construction. • Long operating life. • Compact or remote...
Open the catalog to page 2Big backlit display. Easy adjustment. Operating principle Electromagnetic flowmeters are systems with no moving parts, causing no restriction to the flow, so the pressure drop is irrelevant. Its principle is based on Faraday’s law of induction, which enables accurate and reliable measurements. “Any conductive fluid moving through a magnetic field, induces a voltage which is directly proportional to the speed of the conductor and the amplitude of the magnetic field”. 1. If the system includes pumps, never place the sensor in the pump suction area (A). 2. Place the sensor at the bottom section...
Open the catalog to page 3Compact version Calibration certificate Connections FLOW C Full pipe electrode. FLOW A Measuring electrode. FLOW B Measuring electrode. FLOW X Reference electrode (ground). ANAL Analog output. FREQ Frequency output (calibration only). 230 V L Phase wire 230 V / 50 Hz 230 V PE Ground wire. Order form Nominal diameter