Catalog excerpts
Specular microscope
Open the catalog to page 1Functionality & aesthetics combined The next generation in specular microscopy The Topcon specular microscope SP-1P introduces a modern ergonomic design and innovative features that simplifies its use and increases its efficiency. A large 10.4 inch rotatable touchscreen eliminates the need for a control lever, and can be turned to various angles for better interaction with the patient. By simply tapping on the center of the patients’ pupil displayed on the monitor, the SP-1P auto matically centers, focuses, acquires and analyzes the endothelial cell image. The entire operation takes a few...
Open the catalog to page 2SP-1P Features | ompact and stylish design C - 0.4 inch rotatable touchscreen 1 | uick automatic measurement Q and analysis - Instant acquisition of the analysis results - Intuitive operation | anorama photography function P - ubstantial size increase S of the analyzed area | asy report E - Built-in printer - Export to storage | wo photography modes T - Sequence mode - Free style mode | asy to read screen and comprehensive E analysis software - requently referred values are shown on top F - pleomorphic / polymegethic histogram can A be shown with color
Open the catalog to page 3Features Compact and stylish design Topcon specular microscope SP-1P offers comfort for patients, ease of use, and increased operation speed. The SP-1P can be placed against the wall, because of the rotatable touchscreen. Quick automatic measurement and analysis The SP-1P photographs and displays analyzed data by simply tapping the screen. All functions, alignment, photography and analysis are quickly performed automatically. Conventional analysis area Panorama photography function The ‘panorama’ function takes three images in three different areas: central, nasal and temporal and...
Open the catalog to page 4Features Easy report Sample report After photography the report will be transferred to the selected storage location. Sample printout Direct printout from the device.
Open the catalog to page 5Features Two photography modes The SP-1P offers two photography modes. The examiner can select between sequence mode and free style mode. Sequence mode and analysis of the different areas of the cornea. The examiner can enter patient information prior to This ensures that all necessary information on the photographing and then perform the photograph All operation can be done by the touchscreen, Central Photo Panorama Center/Nasal/Temporal positions can be photographed and integrated Patient registration Select the eye and location to examine S TS C Peripheral Photo Photograph peripheral...
Open the catalog to page 6Easy to read screenExamination screenDisplay analyzed result Patient No. / ID AUTO Pimm touch pupil an I he licreer Target position / total images taken Print / Output Manual editing Move head forward / backward Return Emergency stop Comprehensive analysis software All relevant values such as corneal thickness (CCT), cell density (CD), coefficient of variation (CV) and percentage of cell hexagonality (HEX) are displayed in large font size on top of the measurement screen By tapping the overlay button at the bottom, the analysis graph can be changed to a pleomorphic or polymegethic...
Open the catalog to page 7Specifications Corneal endothelium photography Photography magnification Photography range Revolving power More than 125 line/mm Fixation target Central and (semi) peripheral Corneal thickness measurement 0.400 - 0.750 mm Display unit: 0.001 mm step display Measurement range Other specifications Dimensions Power supply Source voltage Power input * Corneal thickness is measured only when taking a photograph using the central fixation target. System chart LAN Ophthalmic data system Specular Microscope Other filing system Server Subject to change in design and/or specifications without advanced...
Open the catalog to page 8All TOPCON EUROPE POSITIONING catalogs and technical brochures
-
RL-SV2S
2 Pages
-
FC-6000
4 Pages
-
3D CONSTRUCTION
32 Pages
-
2D / 3D Excavator Control
2 Pages
-
IS-1 Series
9 Pages
-
FS-1 series
4 Pages
-
IMAGEnet i-base
2 Pages
-
OMS-800 Series
8 Pages
-
KR-1W
2 Pages
-
CA-800
16 Pages
-
SL-D Series
16 Pages
-
SL-2G
4 Pages
-
SL-D701
2 Pages
-
SL-D701
8 Pages
-
TRC-50DX
8 Pages
-
TRC-NW8 series
8 Pages
-
3D OCT
12 Pages
-
DRI OCT Triton series
20 Pages
-
GT SERIES
4 Pages
-
GR-5
4 Pages
-
3D-MC MAX
4 Pages
-
X-53
2 Pages
-
X-53i
2 Pages
-
DynaRoad
4 Pages
-
Topcon Tierra
4 Pages
-
DL series
4 Pages
-
Robotic Total Stations
4 Pages
-
Dozer GPS + Control
4 Pages
-
Dozer LPS control
4 Pages
-
MACHINE CONTROL CATALOGUE
16 Pages
-
Dozer Laser Control
4 Pages
-
LASER CATALOGUE
12 Pages
-
3D Mobile Mapping System
6 Pages
-
ScanMaster - Data Management
4 Pages
-
TopSURV7
4 Pages
-
Topcon Tesla RTK
4 Pages
-
IP-S2 HD
4 Pages
-
IP-S2 Compact
8 Pages
-
ImageMaster
4 Pages
-
Survey / Mapping CATALOGUE
28 Pages
-
IS Imaging Station
4 Pages
-
Field Controller (FC-250)
4 Pages
-
Laser Scanner (GLS-1500)
4 Pages
Archived catalogs
-
Crossline Laser (LC-2,LC-4X)
4 Pages
-
Laser Range
8 Pages
-
GPS+Receivers (HiPer Pro)
4 Pages
-
GPS+Receivers (Hiper Series)
6 Pages
-
Leaflet FC-200
2 Pages
-
Leaflet ATG-Series
4 Pages