Industriestrasse 7 ▪ 65366 Geisenheim ▪ Germany www.topcon-electronics.de ▪ [email protected] Technical Data Sheet OPUS B6 ECO Basic . 12.04.2021 Errors and technical changes excep
Open the catalog to page 1Industriestrasse 7 ▪ 65366 Geisenheim ▪ Germany www.topcon-electronics.de ▪ [email protected] 1 Notes and Warnings Attention! Please note: This description is not a substitution for the concerned product’s documentation. Please do read the documentation including the manuals carefully before dealing with this product. If the safety instructions in the documentation are not followed dangerous situation can occur that can result in damages, injuries and/or death by high voltage or wrong handling. In case you do not have the correct documentation, you can order it by contacting [email protected]....
Open the catalog to page 2Industriestrasse 7 ▪ 65366 Geisenheim ▪ Germany www.topcon-electronics.de ▪ [email protected] Aluminium die cast Powder coated ● Landscape or portrait ● Standalone
Open the catalog to page 3Industriestrasse 7 ▪ 65366 Geisenheim ▪ Germany www.topcon-electronics.de ▪ [email protected] TFT Color Graphic LCD with LED backlight 10,1’’, 259 mm (W) x 175 mm (H) 1280 x 800 px (WQVGA), 15:9 Size: Resolution: Colors: Brightness: Contrast Ratio: 4 Input Devices Touch Capacitive Touch Light sensor 1 Multicolor LED 5 Electronics Processor platform CPU: Mass storage: RAM: RTC: Freescale I.MX6®, Dual, 800 MHz 4 GByte (minus space for OS & application) 1 GByte Buffered by gold cap Buffered for 2 weeks at Tambien Deviation max. 1 s/day 1 x Audio output (left, right, GND) AC97 compatible Output...
Open the catalog to page 4Industriestrasse 7 ▪ 65366 Geisenheim ▪ Germany www.topcon-electronics.de ▪ [email protected] Power supply System supplied through terminal 30 (battery +, see pinout) and 31 (battery -, see pinout). Terminal 15 (ignition) to be used to switch on/off. Operating voltage range: 8 … 36 V DC. Short circuit protection. Over-voltage protection up to 48 V for max. 5 min. Inverse polarity protection up to -48 V DC for max. 5 min. 6 Interfaces CAN Bus 4 x CAN-Interface according to ISO 11898, CAN-specification 2.0 B active, up to 1 Mbit/s (default 250 Kbit/s, possible 10Kbit/s, 20Kbit/s, 50Kbit/s,...
Open the catalog to page 5Industriestrasse 7 ▪ 65366 Geisenheim ▪ Germany www.topcon-electronics.de ▪ [email protected] 7 Connectors Connectors Main Typo-AMP 1437288-6 Mating connector (customer) Typo-AMP 3-1437290-7 Mating crimp contact (customer) Typo-AMP 3-1447221-4 Dummy Plug (customer) Typo-AMP 4-1437284-3 OPUS displays in the industrial sector are only intended to use with cable length less than 30 meters. VideoConnector M12 round connector, female, 5-pole, B-coded acc. to EN 61076-2-101 M12 round connector, female, 4-pole, D-coded acc. to EN 61076-2-101 8 Software Operating System Application Programming...
Open the catalog to page 6Industriestrasse 7 ▪ 65366 Geisenheim ▪ Germany www.topcon-electronics.de ▪ [email protected] 9 Testing and Verification CE-Compliance EU Directive 2014/30/EU (EMC) according to ● EN 13309: Construction machinery – Electromagnetic compatibility of machines with internal electrical power supply ● EN ISO 14982: Agricultural and forestry machinery – Electromagnetic compatibility – Test methods and acceptance criteria ● EN 50498: Electromagnetic compatibility (EMC). Product family standard for aftermarket electronic equipment in vehicles. ● EN 61000-6-2: Electromagnetic compatibility (EMC)....
Open the catalog to page 7Industriestrasse 7 ▪ 65366 Geisenheim ▪ Germany www.topcon-electronics.de ▪ [email protected] 12V-System (Maximum values) Positive slow pulses: +37V Positive slow pulses: +37V Negative slow pulses: -75V Negative slow pulses: -150V Positive fast pulses: +75V Positive fast pulses: +150V Negative fast pulses: -112V Test Pulse 1 Test Pulse 2a Test Pulse 2b Test Pulse 3a Test Pulse 3b Test Pulse 4 (Starting profile) Load Dump Negative fast pulses: -150V Electrostatic Discharge +/- 8kV contact discharge; FS: A +/- 15kV air discharge; FS: A EMV Susceptibility Conducted Frequency: 150kHz–80MHz;...
Open the catalog to page 8Industriestrasse 7 ▪ 65366 Geisenheim ▪ Germany www.topcon-electronics.de ▪ [email protected] Electrical 12 and 24V-Systems according to: Inverse Polarity resistance 5min @ -48V (no defect) Over voltage resistance 5min @ +48V (no defect) Start behavior Start over Temperature Start at TRoom; decrease in 5°steps to TMin; go to TRoom; increase in 5°steps to THigh; Start DUT at each T; Successful start expected Short circuit strength Connect each Pin of Main-, Video- and Ethernet-Connector for 5 Min to GND and for 5 Min to 36V; FS: C Superimposed alternating voltage Triangle signal, frequency...
Open the catalog to page 9Industriestrasse 7 ▪ 65366 Geisenheim ▪ Germany www.topcon-electronics.de ▪ [email protected] Vibration, noise Frequency [Hz] 32h per Axis; FS: A Vibration, sinusoidal Resonance sweep Endurance Test: Mechanical shock Part 1: 300m/s², 18ms, 10 times per axis/direction; FS: A Part 2: 500m/s², 11ms, 3 times per axis/direction; FS: A Part 3: 500m/s², 6ms, 10 times per axis/direction; FS: A Part 4: 400m/s², 6ms, 4000 times per axis/direction; FS: A Drop Test Drop the DUT on each side and each edge from a high of 1m on a concrete floor. No damage or visible damage. Package Drop Test Drop the...
Open the catalog to page 10Industriestrasse 7 ▪ 65366 Geisenheim ▪ Germany www.topcon-electronics.de ▪ [email protected] Climate Start spray resistance Part 1: 7 cycles at 24h (8h spraying; 16h rest) salt concentration: 5% Chemical resistance Apply once a day, for three days, the following chemicals with a brush over the exposed surface. Inspect without rinsing immediately after-wards and after 100h. Alcohol, Antifreeze liquid (Ethyl-glycol), Diesel oil, Domestic Ammonia, Gasoline, Hydraulic oil 10W40, Liquid lime, Motor oil, NPK Chemical fertilizers 20 10 20, Windscreen cleaning mixture, Ammonium Nitrate and Ammonium...
Open the catalog to page 11Industriestrasse 7 ▪ 65366 Geisenheim ▪ Germany www.topcon-electronics.de ▪ [email protected] 10 Pinout Main connector pinout VCC Ignition Input GND Wake Audio Out L Audio Out R Audio GND CAN1H CAN1L CAN2H CAN2L CAN3H CAN3L CAN4H CAN4L RS232 RxD RS232 TxD RS232 GND SERV_EN - supply voltage +; terminal 30 ignition input; terminal 15 supply voltage -; terminal 31 Wake Input, “Doorswitch” Audio line out, Stereo Audio line out, Stereo Audio line out, Ground CAN 1 high CAN 1 low CAN 2 high CAN 2 low CAN 3 high CAN 3 low CAN 4 high CAN 4 low RS232 receive data RS232 transmit data RS232 GND Not...
Open the catalog to page 1211 Pages
11 Pages
11 Pages
14 Pages
2 Pages
8 Pages
10 Pages
9 Pages
10 Pages
10 Pages
10 Pages
10 Pages
10 Pages
8 Pages
8 Pages
8 Pages
8 Pages
8 Pages
8 Pages
8 Pages
8 Pages
6 Pages
9 Pages
9 Pages
8 Pages
8 Pages
8 Pages
6 Pages
8 Pages
8 Pages
8 Pages
10 Pages
9 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
8 Pages
32 Pages
2 Pages
2 Pages