Particle Analysis System for Fluids Series FAS 362
Measuring Method: The FAS 362 employs single particle counting methods for particle sizing and concentration measurements. This optical method offers high sensitivity and accuracy, with a quick response time, and does not rely on assumptions about particle distribution.
Main Advantages: The system features a non-contact optical method, a wide range of concentration and particle sizes, low dependency on particle material, and user-friendly software. It is robust, compact, and lightweight.
Applications: The FAS 362 is suitable for measuring particle size distributions, cleanness analysis, separation efficiency determination, flocculation investigations, and biological or bacterial system analysis.
Principle: The system consists of a sensor and a signal processing unit. The sensor includes an optical setup and a sample unit. Particles cause light extinction, which is measured to determine size and concentration. The signal processing unit classifies these measurements into channels for analysis.
Options: The system can connect to a micro balance for precise volume measurement and includes a pump for continuous sampling. The sample unit is designed for easy handling and cleaning.
Software PASWin: This Windows® software calculates particle size distributions and allows for data exchange with other applications. It supports real-time data acquisition and communication with a micro balance for accurate flow rate measurement.
Specifications: The system offers a measuring range of 1-200µm, with a maximum particle concentration of 20,000 particles/cm³. It uses a laser diode light source and is powered by 100-260VAC. The system is compact and lightweight, with a signal processing unit weighing 2.1kg.
Calibration: Users can calibrate the system using a transfer model or direct assignment. High-resolution calibration minimizes errors, and repeated measurements ensure quality assurance.
Compliance: Topas GmbH is certified under DIN EN ISO 9001:2000, ensuring high-quality standards in particle technology and filter testing.
See more

Catalog excerpts

Particle Analysis System for Fluids Series FAS -1

TOPAS i® Particle Analysis System for Fluids Sries FAS Main Advantages Non touching, optical measuring method with quick response 镕 Wide concentration and particle size range Extreme low dependency on particle material by the use of especially developed patented optics Օ Optimally designed sensing volume No assumption of distribution function Օ User friendly Windows® software Easy to use Օ Robust, small dimensions and low weight Application Measurement of particle size distributions as well as concentrations Օ Cleanness analysis Determination of separation efficiencies Օ Flocculation investigations Analysis of biological or bacterial systems Particle Analysis System for Fluids FAS 362 Measuring Method Particle sizing methods based on single particle counting classify a physically measurable quantity according to particle size independently and under no assumptions. Such methods provide high sensibility and accuracy combined with very quick response of particle system analysis. A further advantage is that the correlation between optical effects and particle size can transparently be described. Based on such optical, single particle counting methods the series FAS was developed for particle sizing as well as concentration measurements with high sensitivity and resolution in a wide concentration range. CD Photo Detector Light Source Determination of particle cross section or diameter Scheme of the Optical Unit

 Open the catalog to page 1
Particle Analysis System for Fluids Series FAS -2

Principle Principle Options The measuring instrument of the sries FAS can be divided into two main components: the sensor and the signal processing unit. The sensor is mounted separately and contains the optical measuring setup (light source, measuring cell, photo detector and amplifier) and a sample unit with glass vessel, stirrer and a magnetic valve for sample flow control. For the series FAS, the physical effect is used where an illuminated particle will cause a definite light extinction (blockage) corresponding to its cross section and size, respectively. For this, the particle system is...

 Open the catalog to page 2
Particle Analysis System for Fluids Series FAS -3

Software PASWin Topas Particle Analyzer Software PASWin Runs under Windows® Օ Calculation of diffrent type particle size distributions weighted by number, surface or volume Display and printouts as graphics or table 镕 User defined integration limit, channel resolution, logarithmic and linear size axis Background measurement and real-time subtraction Օ Multi tasking Data exchange with other Windows® applications (clipboard, DDE) Օ Communication with micro balance via RS232 interface (optional) for precise flow rate measurement Data logger for long term investigations saves single measurement...

 Open the catalog to page 3
Particle Analysis System for Fluids Series FAS -4

Spcifications Calibration by the user A transfer model serves the purpose of assigning particle characteristics (e.g. equivalent particle diameter) to a measurable quantity (e.g. pulse height. Such a model method can be a mathematical model or it can be based on the direct assignment of a measurable quantity to a characteristic of a particle. The direct assignment is called calibration. By means of high-resolution calibration (as high as possible) is minimized the error between measured and calculated values. Furthermore, repeating the measurement of a selected reference material system is used...