1. Catalogs
  2. Top Cable
  3. TOPCABLE_X-DRINK_EN

TOPCABLE_X-DRINK_EN

TOPCABLE_X-DRINK_EN

TOPCABLE_X-DRINK_EN

Product catalog summary
Design Specifications
  • Conductor: Made of electrolytic copper, class 5 (flexible), compliant with EN 60228 and IEC 60228 standards.
  • Insulation: Utilizes cross-linked polyethylene (XLPE) with standard color identification for insulated conductors.
  • Lay-up: Conductors are arranged side by side in a parallel configuration, with an optional round version available.
  • Outer Sheath: Composed of flexible polyolefin, colored blue.
Applications
  • Suitable for permanent submersion in environments such as submerged pumps for drinking water, wells, aquariums, lighting systems, and swimming pool cleaning.
  • Recommended for electrical installations in food and beverage production, processing, and preservation systems.
  • Submersible up to 600 meters deep.
Characteristics
  • Electrical Performance: Low voltage 0.6/1kV with CE and RoHS approvals.
  • Thermal Performance: Maximum service temperature of 90ºC, short-circuit temperature of 250ºC (max. 5 seconds), and minimum service temperature of -40ºC for fixed and protected installations.
  • Fire Performance: LSZH (Low Smoke Zero Halogen) compliant with UNE-EN 60754-1 and IEC 60754-1, with low corrosive gas emission.
  • Mechanical Performance: Minimum bending radius is five times the cable diameter, with medium severity impact resistance (AG2).
  • Chemical Performance: Excellent resistance to chemicals and oil.
  • Water Performance: Water resistance rated AD8, suitable for deep wells and submersible pump cables for drinking water according to AS/NZS 4020.
  • Other Features: Meter by meter marking for installation.
Installation Conditions
  • Designed for submerged and industrial use, including deep wells, aquariums, fishponds, and swimming pools.
See more

Catalog excerpts

TOPCABLE_X-DRINK_EN-1

X-DRINK 0,6/1 kV Cables for submersed pumps and drinking water DESIGN 1. Conductor Electrolytic copper, class 5 (flexible), based on EN 60228 and IEC 60228. 2. Insulation Cross-linked polyethylene (XLPE). The standard identification of insulated conductors is the following: Brown+ Black+ Grey Brown + Black + Grey + Green/yellow Brown + Black + Grey + Blue 3. Lay-up Insulated conductors are placed side by side in parallel arrangement. On request, Xdrink is also available in a round version. 4. Outer sheath Flexible polyolefin, blue colour. APPLICATIONS XDrink 0,6/1 kV is a flexible cable suitable for being permanently submerged, such as: submerged pumps for drinking water, wells and aquariums. It is also suitable for lighting systems, filtering and swimming pool’s cleaning. Finally, its use is recommended in electrical installations for the production, processing and preservation of food and beverage systems. Submersible (up to 600 meters deep) .

 Open the catalog to page 1
TOPCABLE_X-DRINK_EN-2

Chemical performance Chemical & Oil resistance: Excellent. Electrical performance LOW VOLTAGE 0,6/1kV Thermal performance Maximum service temperature: 90°C. Maximum short-circuit temperature: 250°C (max. 5 s). Minimum service temperature: -40°C (fixed and protected installations). Fire performance LSZH (Low Smoke Zero Halogen) based on UNE-EN 60754-1 and IEC 60754-1. Low corrosive gases emission based on UNE-EN 60754-2 and IEC 60754-2. Mechanical performance Minimum bending radius: x5 cable diameter. Impact resistance: AG2 Medium severity. Water performance Water resistance: AD8 submerged.. For...

 Open the catalog to page 2

All Top Cable catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.