Design Specifications
  • Conductor: Made of electrolytic copper, class D (extra-flexible), compliant with UNE-EN 50525-2-81.
  • Outer Sheath: Composed of flexible rubber, black in color.

Applications

The Topweld H01N2-D is a flexible rubber welding cable designed for high current transmission between welding generators and electrodes. Its flexibility aids in preventing knots that could damage the internal conductor. It is suitable for automatic welding, machine tools, conveyor systems, and production or assembly lines, such as those in the automotive industry.


Characteristics
  • Electrical Performance: Operates at low voltage 100/100V, adhering to EN 50525-2-81 / IEC 60245 standards.
  • Approvals: CE, HAR, AENOR, SASO, RoHS.
  • Thermal Performance: Maximum service temperature is 85ºC, with a short-circuit temperature of 250ºC for up to 5 seconds. Minimum service temperature is -20ºC.
  • Fire Performance: Non-propagation of flame as per UNE-EN 60332-1 and IEC 60332-1.
  • Mechanical Performance: Minimum bending radius is five times the cable diameter, with medium severity impact resistance (AG2).
  • Chemical Performance: Excellent resistance to chemicals, oil, grease, and mineral oils.
  • Water Performance: Resistant to sprays (AD3).
  • Other Features: Meter by meter marking for easy measurement.

Installation Conditions

Suitable for open air installations and applicable in welding, industrial, mobile, robotics, and conveyor uses.

See more

Catalog excerpts

TOPCABLE_TOPWELD_H01N2-D_EN-1

The special cable for welding. UNE-EN 50525-2-81 / IEC 60245 DESIGN 1. Conductor Electrolytic copper, class D (extra-flexible), based on UNE-EN 50525-2-81. 2. Outer sheath Flexible rubber. Black colour. APPLICATIONS Topweld H01N2-D is a harmonized, flexible, rubber welding cable specially designed for transmitting high currents between the welding generator and the electrode. Its flexibility makes using the welding tool easier and also prevents knots from forming in the cable that could cause the internal conductor to break. It can also be used in automatic welding and machine tools, conveyor systems and production or assembly lines, for example in automobile assembly lines. This cable render is an example from this product does not neccesarily match the selected core size or number of cores.

 Open the catalog to page 1
TOPCABLE_TOPWELD_H01N2-D_EN-2

CHARACTERISTICS Electrical performance LOW VOLTAGE 100/100V Chemical performance Chemical & Oil resistance: Excellent. Grease & mineral oils resistance: Excellent Water performance Water resistance: AD3 Sprays Approvals CE HAR AENOR SASO RoHS Thermal performance Maximum service temperature: 85ºC. Maximum short-circuit temperature: 250ºC (max. 5 s). Minimum service temperature: -20ºC. Fire performance Flame non-propagation based on UNE-EN 60332-1 and IEC 60332-1. Mechanical performance Minimum bending radius: x5 cable diameter. Impact resistance: AG2 Medium severity. Other Meter by meter marking....

 Open the catalog to page 2

All Top Cable catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.