1. Catalogs
  2. Top Cable
  3. INDUSTRIAL CABLES CATALOGUE | 2024

INDUSTRIAL CABLES CATALOGUE | 2024

INDUSTRIAL CABLES CATALOGUE | 2024
1 / 66 PagesView full catalog

INDUSTRIAL CABLES CATALOGUE | 2024

Product catalog summary
Standards and Compliance
Power cables for industrial installations comply with IEC 60502-1 and UNE 21123-2 standards. They are approved by AENOR, Bureau Veritas, KEMA-KEUR, and meet RoHS and CE requirements. The cables are also compliant with the Construction Products Regulation (CPR) with a classification of Eca.
Product Overview
The POWERFLEX® RV-K is an industrial flexible cable designed for power transmission. It is suitable for low voltage connections in various settings, including urban grids and building installations. Its flexibility facilitates installation in challenging layouts, and it can be used both outdoors and underground without additional protection. The cable is resistant to damp conditions and can be fully submerged in water.
Construction Details
The cable features an electrolytic annealed copper conductor, class 5, with cross-linked polyethylene insulation. The outer sheath is made of flexible PVC, black in color. The cable's electrical performance supports low voltage of 0.6/1 kV, with a maximum service temperature of 90°C and a short-circuit temperature of 250°C.
Fire and Environmental Performance
The cable is flame retardant and has reduced halogen emissions. It is UV resistant and offers good chemical and oil resistance. The cable can withstand medium severity impacts and has a minimum bending radius of five times the cable diameter.
Dimensions and Electrical Characteristics
The document provides detailed tables of cable dimensions, weights, and electrical characteristics, including current-carrying capacities in open air and buried conditions, as well as voltage drop values.
Correction Factors
Correction factors for air and ground temperatures, as well as soil thermal resistivity, are provided to adjust the cable's performance under different environmental conditions.
Additional Product: POWERFLEX® PLUS YMvKf
This cable variant offers improved fireproof properties and is suitable for use in public places and hazardous industries. It shares similar construction and performance characteristics with the RV-K model but has enhanced fire resistance, classified as Cca-s2,d2,a3 under CPR.
Specifications and Standards:
The document outlines the specifications for TOXFREE® ZH cables, which are flexible, low smoke halogen-free (LSHF) power cables designed for public places. These cables comply with standards such as IEC 60502-1 and UNE 21123-4, and are approved by AENOR, KEMA-KEUR, RoHS, and CE. They meet the Construction Products Regulation (CPR) classifications B2ca-s1a,d1,a1 or Cca-s1a,d1,a1 depending on the cross-section.
Applications:
TOXFREE® ZH cables are recommended for use in public places like hospitals, schools, museums, airports, and shopping centers due to their safety features in the event of a fire, such as not emitting toxic or corrosive gases.
Construction:
The cables feature an electrolytic annealed copper conductor, class 5 (flexible), with cross-linked polyethylene (XLPE) insulation. The outer sheath is made of LSHF polyolefin, available in grey or black.
Characteristics:
  • Electrical Performance: Low voltage of 0.6/1 kV.
  • Thermal Performance: Maximum service temperature of 90ºC, short-circuit temperature of 250ºC, and minimum service temperature of -40ºC.
  • Fire Performance: Non-propagation of flame and fire, low smoke emission, and low corrosive gases emission.
  • Mechanical Performance: Minimum bending radius of 5x cable diameter and medium severity impact resistance.
  • Environmental Performance: Resistant to chemicals, oil, UV, and water jets.
Installation Conditions:
The cables can be installed in open air, buried, or in conduits.
Dimensions and Admissible Intensities:
The document provides detailed tables of cable dimensions, weights, and admissible current intensities for various cross-sections, both in open air and buried conditions, along with voltage drop values.
Correction Factors:
Correction factors for air and ground temperature, soil thermal resistivity, and other conditions are provided to adjust the cable's performance under different environmental conditions.
Overview: This document provides technical specifications and guidelines for the Toxfree® ZH series of cables, which are low smoke halogen-free (LSHF) power cables designed for use in public places. These cables are compliant with various international standards and are designed to minimize toxic and corrosive gas emissions in the event of a fire.
Specifications:
  • Conductor: Electrolytic annealed copper, class 5 (flexible), compliant with EN 60228 and IEC 60228.
  • Insulation: Cross-linked polyethylene (XLPE) and special polyolefin, LSHF.
  • Outer Sheath: LSHF polyolefin, green color, non-toxic, and fire retardant.
  • Electrical Performance: Low voltage 0.6/1 kV.
  • Thermal Performance: Maximum service temperature of 90°C, short-circuit temperature of 250°C for up to 5 seconds, and minimum service temperature of -40°C.
Fire and Environmental Performance:
  • Flame and fire non-propagation according to IEC 60332-1 and EN 50399.
  • Low smoke emission with light transmittance greater than 80%.
  • Low corrosive gas emission according to EN 60754-2.
  • UV and water-resistant, with acceptable chemical and oil resistance.
Applications: Recommended for use in public places such as hospitals, schools, museums, airports, and shopping centers due to its safety features in fire conditions.
Standards and Compliance:
  • Compliant with IEC 60502-1, UNE 21123-4, RoHS, and CE standards.
  • Construction Products Regulation (CPR) classifications: B2ca-s1a,d1,a1 or Cca-s1a,d1,a1.
Correction Factors:
  • Air and ground temperature correction factors are provided for various temperatures.
  • Soil thermal resistivity correction factors are given based on moisture levels.
Dimensions and Admissible Intensities: Detailed tables provide information on cross-section, diameter, weight, and current-carrying capacities for different installation conditions.
Additional Notes: Top Cable reserves the right to modify data sheets without prior notice, and all specifications are indicative only.
Introduction
This document provides technical specifications and performance characteristics for various types of cables produced by Top Cable, including TOXFREE® ZH, TOPDRIVE® VFD (EMC), and SCREENFLEX® 110/200. These cables are designed for specific applications such as low smoke emission, electromagnetic interference reduction, and safe signal transmission.

Specifications
  • Insulated Conductor Identification: The document outlines the standard identification for insulated conductors according to UNE 21089-1 and HD 308, detailing color codes for different configurations.
  • Screen and Outer Sheath: Cables feature a 100% coverage screen composed of aluminum-polyester tape and tinned copper braid. The outer sheath is made of Low Smoke Halogen Free (LSHF) polyolefin, which is non-toxic and fire retardant.

Performance Characteristics
  • Electrical Performance: Cables are rated for low voltage (0.6/1 kV).
  • Thermal Performance: Maximum service temperature is 70°C, with a short-circuit temperature of 160°C for TOXFREE® ZH and 250°C for TOPDRIVE® VFD.
  • Fire Performance: Cables are flame and fire non-propagating according to EN and IEC standards, with low smoke and corrosive gas emissions.
  • Mechanical Performance: Minimum bending radius is specified, with medium severity impact resistance.
  • Environmental Performance: Cables are resistant to chemicals, oil, UV, and water.

Installation Conditions
Cables can be installed in open air, buried, or in conduit, with specific conditions outlined for each type.

Dimensions and Admissible Intensities
The document provides detailed tables of dimensions, weights, and admissible current intensities for various cable cross-sections, along with voltage drop values.

Short-Circuit Current-Carrying Capacities
Tables are provided for short-circuit current-carrying capacities over different time durations.

Correction Factors
Correction factors for air and ground temperature, as well as soil thermal resistivity, are provided to adjust performance calculations.

Standards and Compliance
Cables comply with various international standards and approvals, including RoHS, CE, and CPR regulations.

Applications
  • TOPDRIVE® VFD (EMC): Designed for Variable Frequency Drive Motors to limit electromagnetic interference.
  • SCREENFLEX® 110/200: Used for safe signal transmission in control circuits and electronic equipment.
Overview
This document provides technical specifications and compliance information for various cable products by Top Cable, including Toxfree® ZH H05Z-K & H07Z-K, Xtrem® H07RN-F, and Toxfree® Xtrem ZH H07ZZ-F (AS). These cables are designed for different applications, including fixed installations, mobile services, and industrial use, with a focus on safety and environmental standards.
Toxfree® ZH H05Z-K & H07Z-K
  • Application: Suitable for fixed and protected installations in public places like hospitals and schools. Not suitable for wet or submerged environments.
  • Construction: Features a flexible copper conductor and halogen-free rubber insulation.
  • Electrical Performance: Rated for low voltage (300/500 V for H05Z-K and 450/750 V for H07Z-K).
  • Thermal Performance: Operates at a maximum temperature of 90ºC, with a short-circuit temperature of 250ºC.
  • Fire Performance: Non-propagating flame characteristics and low smoke emission.
  • Standards: Complies with EN 50525-2-31 and other relevant standards.
Xtrem® H07RN-F
  • Application: Designed for industrial and mobile use, including powering motors and submersible pumps.
  • Construction: Composed of a flexible copper conductor and thermosetting rubber insulation.
  • Electrical Performance: Suitable for low voltage applications (450/750V).
  • Thermal Performance: Maximum service temperature of 90°C.
  • Fire Performance: Flame non-propagation and CPR Eca classification.
  • Environmental Performance: Excellent resistance to chemicals, oils, and water.
  • Standards: Complies with EN 50525-2-21 and other standards.
Toxfree® Xtrem ZH H07ZZ-F (AS)
  • Application: Suitable for mobile services requiring low smoke and halogen-free emissions, such as industrial and agricultural applications.
  • Construction: Features a flexible copper conductor and halogen-free rubber insulation.
  • Electrical Performance: Rated for low voltage (450/750 V).
  • Thermal Performance: Operates at a maximum temperature of 90ºC.
  • Fire Performance: Non-propagating flame characteristics and low smoke emission.
  • Environmental Performance: Excellent resistance to chemicals, oils, and water immersion.
  • Standards: Complies with EN 50525-3-21 and other standards.
General Notes
Top Cable reserves the right to modify data sheets without prior notice. All specifications are indicative and not binding.
Overview: This document provides technical specifications and guidelines for Top Cable's POWERHARD® AL and TOXFREE® ZH cables, focusing on their construction, performance, and application in power transmission.
Specifications:
  • POWERHARD® AL RV 1.8/3 kV AL: An aluminium cable designed for underground networks and low voltage connections. It features a class 2 aluminium conductor, XLPE insulation, and a PVC outer sheath. It is compliant with IEC 60502-1 and RoHS/CE standards.
  • TOXFREE® ZH RZ1 (AS) Al: An aluminium low smoke halogen-free (LSHF) cable suitable for fixed installations, especially in public places. It includes a class 2 aluminium conductor, XLPE insulation, and a green LSHF polyolefin outer sheath. It meets IEC 60502-1 and UNE 21123-4 standards.
Performance Characteristics:
  • Electrical: Both cables support low voltage applications, with POWERHARD® AL rated at 1.8/3 kV and TOXFREE® ZH at 0.6/1 kV.
  • Thermal: Maximum service temperature is 90ºC, with a short-circuit temperature of 250ºC for both cables.
  • Fire: Both cables exhibit flame non-propagation and reduced halogen emissions, with TOXFREE® ZH also offering low smoke emission and low corrosive gas emission.
  • Mechanical: Minimum bending radius is five times the cable diameter, with medium impact resistance.
  • Environmental: Both cables are UV and water-resistant, with TOXFREE® ZH offering additional chemical and oil resistance.
Installation Conditions: Cables can be installed in open air, buried, or in conduits. Correction factors for air and ground temperature, as well as soil thermal resistivity, are provided to adjust cable performance under different environmental conditions.
Dimensions & Admissible Intensities: Detailed tables provide cross-section dimensions, weight, and admissible current intensities for both open air and buried installations, along with voltage drop values.
Company Information: Top Cable is a global manufacturer based in Barcelona, Spain, specializing in high-quality industrial and power cables. The company emphasizes innovation, with a focus on research and development to produce high-performance cables for various applications.
See more

Catalog excerpts

INDUSTRIAL CABLES CATALOGUE | 2024-1

Industrial Cables Power cables for industrial installations

 Open the catalog to page 1
INDUSTRIAL CABLES CATALOGUE | 2024-2

Driving your energy

 Open the catalog to page 2
INDUSTRIAL CABLES CATALOGUE | 2024-3

POWERFLEX® RV-K Industrial flexible cable for power transmission. CHARACTERISTICS Powerflex® RV-K cable is suitable for all types of low voltage industrial-type connections, in urban grids, building installations, etc. Its high flexibility makes the installation process substantially easier and, as a result, is particularly suitable for use in difficult layouts. It can be buried or installed in a tube as well as outdoors without requiring additional protection. This cable can withstand damp conditions including total immersion in water (AD7). CONSTRUCTION Conductor Electrolytic annealed copper...

 Open the catalog to page 3
INDUSTRIAL CABLES CATALOGUE | 2024-4

POWERFLEX® RV-KDIMENSIONS & ADMISSIBLE INTENSITIES Cross-section (mm2) [email protected] | www.topcable.com © 2021 Top Cable - Version 23 - 23.07.2021 | Issued DVC Top Cable reserves the right to carry out any modification to the data sheets whatsoever without giving previous notice. All renders, specifications and particulars of weights, size and dimensions contained in this documentation is indicative only and shall not be binding on Top Cable.

 Open the catalog to page 4
INDUSTRIAL CABLES CATALOGUE | 2024-5

1 Reference method F for single-core and method E for multicore cables according to IEC 60364-5-52 in open air at 30°C ambient temperature. 2 Reference method D2 according to IEC 60364-5-52. Directly buried at 0,7 m depth with soil thermal resistivity of 2,5 K-m/W and 20°C of ground temperature. 3 At maximum service temperature and cosj=1. In all cases it is supposed a single-phase circuit. [email protected] | www.topcable.com © 2021 Top Cable - Version 23 - 23.07.2021 | Issued DVC Top Cable reserves the right to carry out any modification to the data sheets whatsoever without giving previous...

 Open the catalog to page 5
INDUSTRIAL CABLES CATALOGUE | 2024-6

POWERFLEX® RV-K SHORT-CIRCUIT CURRENT-CARRYING CAPACITIES [email protected] | www.topcable.com © 2021 Top Cable - Version 23 - 23.07.2021 | Issued DVC Top Cable reserves the right to carry out any modification to the data sheets whatsoever without giving previous notice. All renders, specifications and particulars of weights, size and dimensions contained in this documentation is indicative only and shall not be binding on Top Cable.

 Open the catalog to page 6
INDUSTRIAL CABLES CATALOGUE | 2024-7

POWERFLEX® PLUS YMvKf The universal cable for power transmission with improved fire proof properties. TOEPASSING Powerflex® Plus YMvKf cable is suitable for all types of industrial low voltage connections, urban grids, building installations, etc. This cable is fire retardant and is recommended for use in public places and hazardous industries. Its flexibility makes installation substantially easier, making it highly suitable for difficult layouts. This cable can also be used in buried installations or in tubes or outdoors without requiring additional protection. This cable withstands damp conditions...

 Open the catalog to page 7
INDUSTRIAL CABLES CATALOGUE | 2024-8

POWERFLEX® PLUS YMvKfDIMENSIONS & ADMISSIBLE INTENSITIES Cross-section (mm2) [email protected] | www.topcable.com © 2021 Top Cable - Revision 17 - 05.07.2021 | Issued JAM Top Cable reserves the right to carry out any modification to the data sheets whatsoever without giving previous notice. All renders, specifications and particulars of weights, size and dimensions contained in this documentation is indicative only and shall not be binding on Top Cable.

 Open the catalog to page 8
INDUSTRIAL CABLES CATALOGUE | 2024-9

POWERFLEX® PLUS YMvKf Cross-section (mm2) 1 Reference method F for single-core and method E for multicore cables according to IEC 60364-5-52 in open air at 30°C ambient temperature. 2 Reference method D2 according to IEC 60364-5-52. Directly buried at 0,7 m depth with soil thermal resistivity of 2,5 K-m/W and 20°C of ground temperature. 3 At maximum service temperature and cos j=1. For all cables is supposed a single-phase circuit. [email protected] | www.topcable.com © 2021 Top Cable - Revision 17 - 05.07.2021 | Issued JAM Top Cable reserves the right to carry out any modification to the data...

 Open the catalog to page 9
INDUSTRIAL CABLES CATALOGUE | 2024-10

POWERFLEX® PLUS YMvKf SHORT-CIRCUIT CURRENT-CARRYING CAPACITIES Other correction factors (for grouping cables, for harmonic currents), that are not in this specification, can be applied. Further information can be found in IEC 60364-5-52. [email protected] | www.topcable.com © 2021 Top Cable - Revision 17 - 05.07.2021 | Issued JAM Top Cable reserves the right to carry out any modification to the data sheets whatsoever without giving previous notice. All renders, specifications and particulars of weights, size and dimensions contained in this documentation is indicative only and shall not be...

 Open the catalog to page 10
INDUSTRIAL CABLES CATALOGUE | 2024-11

Top Cable TOXFREE® ZH YMzlKf Flexible LSHF power cable, for public places. CONFORM: IEC 60502-1 / UNE 21123-4 B2ca Cca APPLICATION Toxfree® ZH YMzlKf is a LSHF safety cable. In the event of fire, it does not emit toxic gases, nor does it give off corrosive gases, avoiding any possible damage to people or electronic equipment. For these reasons it is highly recommended for use in public places such as: hospitals, schools, museums, airports, bus terminals, shopping centers, offices, laboratories, etc. • Industrial use. • Public places y Electrical performance Low voltage: 0,6/1 kV Thermal performance...

 Open the catalog to page 11
INDUSTRIAL CABLES CATALOGUE | 2024-12

TOXFREE® ZH YMzlKfDIMENSIONS & ADMISSIBLE INTENSITIES Cross-section (mm2) [email protected] | www.topcable.com © 2021 Top Cable - Version 23 -08.06.2021 | Issued by JAM Top Cable reserves the right to carry out any modification to the data sheets whatsoever without giving previous notice. All renders, specifications and particulars of weights, size and dimensions contained in this documentation is indicative only and shall not be binding on Top Cable.

 Open the catalog to page 12
INDUSTRIAL CABLES CATALOGUE | 2024-13

TOXFREE® ZH YMzlKf Cross-section (mm2) 1 Reference method F for single-core and method E for multicore cables according to IEC 60364-5-52 in open air at 30°C ambient temperature. 2 Reference method D2 according to IEC 60364-5-52. Directly buried at 0,7 m depth with soil thermal resistivity of 2,5 K-m/W and 20°C of ground temperature. 3 At maximum service temperature and cosj=1. In all cases it is supposed a single-phase circuit. [email protected] | www.topcable.com © 2021 Top Cable - Version 23 -08.06.2021 | Issued by JAM Top Cable reserves the right to carry out any modification to the data...

 Open the catalog to page 13

All Top Cable catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry