1. Catalogs
  2. Top Cable
  3. INDUSTRIAL CABLES CATALOGUE | 2024

INDUSTRIAL CABLES CATALOGUE | 2024
1 /66Pages

INDUSTRIAL CABLES CATALOGUE | 2024

INDUSTRIAL CABLES CATALOGUE | 2024
1 /66Pages

Catalog excerpts

INDUSTRIAL CABLES CATALOGUE | 2024-2

Driving your energy

 Open the catalog to page 2
INDUSTRIAL CABLES CATALOGUE | 2024-3

POWERFLEX® RV-K Industrial flexible cable for power transmission. CHARACTERISTICS Powerflex® RV-K cable is suitable for all types of low voltage industrial-type connections, in urban grids, building installations, etc. Its high flexibility makes the installation process substantially easier and, as a result, is particularly suitable for use in difficult layouts. It can be buried or installed in a tube as well as outdoors without requiring additional protection. This cable can withstand damp conditions including total immersion in water (AD7). CONSTRUCTION Conductor Electrolytic annealed copper...

 Open the catalog to page 3
INDUSTRIAL CABLES CATALOGUE | 2024-4

POWERFLEX® RV-KDIMENSIONS & ADMISSIBLE INTENSITIES Cross-section (mm2) [email protected] | www.topcable.com © 2021 Top Cable - Version 23 - 23.07.2021 | Issued DVC Top Cable reserves the right to carry out any modification to the data sheets whatsoever without giving previous notice. All renders, specifications and particulars of weights, size and dimensions contained in this documentation is indicative only and shall not be binding on Top Cable.

 Open the catalog to page 4
INDUSTRIAL CABLES CATALOGUE | 2024-5

1 Reference method F for single-core and method E for multicore cables according to IEC 60364-5-52 in open air at 30°C ambient temperature. 2 Reference method D2 according to IEC 60364-5-52. Directly buried at 0,7 m depth with soil thermal resistivity of 2,5 K-m/W and 20°C of ground temperature. 3 At maximum service temperature and cosj=1. In all cases it is supposed a single-phase circuit. [email protected] | www.topcable.com © 2021 Top Cable - Version 23 - 23.07.2021 | Issued DVC Top Cable reserves the right to carry out any modification to the data sheets whatsoever without giving previous...

 Open the catalog to page 5
INDUSTRIAL CABLES CATALOGUE | 2024-6

POWERFLEX® RV-K SHORT-CIRCUIT CURRENT-CARRYING CAPACITIES [email protected] | www.topcable.com © 2021 Top Cable - Version 23 - 23.07.2021 | Issued DVC Top Cable reserves the right to carry out any modification to the data sheets whatsoever without giving previous notice. All renders, specifications and particulars of weights, size and dimensions contained in this documentation is indicative only and shall not be binding on Top Cable.

 Open the catalog to page 6
INDUSTRIAL CABLES CATALOGUE | 2024-7

POWERFLEX® PLUS YMvKf The universal cable for power transmission with improved fire proof properties. TOEPASSING Powerflex® Plus YMvKf cable is suitable for all types of industrial low voltage connections, urban grids, building installations, etc. This cable is fire retardant and is recommended for use in public places and hazardous industries. Its flexibility makes installation substantially easier, making it highly suitable for difficult layouts. This cable can also be used in buried installations or in tubes or outdoors without requiring additional protection. This cable withstands damp conditions...

 Open the catalog to page 7
INDUSTRIAL CABLES CATALOGUE | 2024-8

POWERFLEX® PLUS YMvKfDIMENSIONS & ADMISSIBLE INTENSITIES Cross-section (mm2) [email protected] | www.topcable.com © 2021 Top Cable - Revision 17 - 05.07.2021 | Issued JAM Top Cable reserves the right to carry out any modification to the data sheets whatsoever without giving previous notice. All renders, specifications and particulars of weights, size and dimensions contained in this documentation is indicative only and shall not be binding on Top Cable.

 Open the catalog to page 8
INDUSTRIAL CABLES CATALOGUE | 2024-9

POWERFLEX® PLUS YMvKf Cross-section (mm2) 1 Reference method F for single-core and method E for multicore cables according to IEC 60364-5-52 in open air at 30°C ambient temperature. 2 Reference method D2 according to IEC 60364-5-52. Directly buried at 0,7 m depth with soil thermal resistivity of 2,5 K-m/W and 20°C of ground temperature. 3 At maximum service temperature and cos j=1. For all cables is supposed a single-phase circuit. [email protected] | www.topcable.com © 2021 Top Cable - Revision 17 - 05.07.2021 | Issued JAM Top Cable reserves the right to carry out any modification to the data...

 Open the catalog to page 9
INDUSTRIAL CABLES CATALOGUE | 2024-10

POWERFLEX® PLUS YMvKf SHORT-CIRCUIT CURRENT-CARRYING CAPACITIES Other correction factors (for grouping cables, for harmonic currents), that are not in this specification, can be applied. Further information can be found in IEC 60364-5-52. [email protected] | www.topcable.com © 2021 Top Cable - Revision 17 - 05.07.2021 | Issued JAM Top Cable reserves the right to carry out any modification to the data sheets whatsoever without giving previous notice. All renders, specifications and particulars of weights, size and dimensions contained in this documentation is indicative only and shall not be...

 Open the catalog to page 10
INDUSTRIAL CABLES CATALOGUE | 2024-11

Top Cable TOXFREE® ZH YMzlKf Flexible LSHF power cable, for public places. CONFORM: IEC 60502-1 / UNE 21123-4 B2ca Cca APPLICATION Toxfree® ZH YMzlKf is a LSHF safety cable. In the event of fire, it does not emit toxic gases, nor does it give off corrosive gases, avoiding any possible damage to people or electronic equipment. For these reasons it is highly recommended for use in public places such as: hospitals, schools, museums, airports, bus terminals, shopping centers, offices, laboratories, etc. • Industrial use. • Public places y Electrical performance Low voltage: 0,6/1 kV Thermal performance...

 Open the catalog to page 11
INDUSTRIAL CABLES CATALOGUE | 2024-12

TOXFREE® ZH YMzlKfDIMENSIONS & ADMISSIBLE INTENSITIES Cross-section (mm2) [email protected] | www.topcable.com © 2021 Top Cable - Version 23 -08.06.2021 | Issued by JAM Top Cable reserves the right to carry out any modification to the data sheets whatsoever without giving previous notice. All renders, specifications and particulars of weights, size and dimensions contained in this documentation is indicative only and shall not be binding on Top Cable.

 Open the catalog to page 12
INDUSTRIAL CABLES CATALOGUE | 2024-13

TOXFREE® ZH YMzlKf Cross-section (mm2) 1 Reference method F for single-core and method E for multicore cables according to IEC 60364-5-52 in open air at 30°C ambient temperature. 2 Reference method D2 according to IEC 60364-5-52. Directly buried at 0,7 m depth with soil thermal resistivity of 2,5 K-m/W and 20°C of ground temperature. 3 At maximum service temperature and cosj=1. In all cases it is supposed a single-phase circuit. [email protected] | www.topcable.com © 2021 Top Cable - Version 23 -08.06.2021 | Issued by JAM Top Cable reserves the right to carry out any modification to the data...

 Open the catalog to page 13

All Top Cable catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.