Pump Characteristics and Cooling Capacity
The document provides a detailed overview of the pump characteristics and cooling capacity for Tool-Temp AG's equipment. It includes a fluidic diagram with key components such as a 2-way valve, pump motor, cooling coil, and various sensors (flow, temperature, pressure). The cooling capacity is illustrated in relation to the temperature difference between flow and cooling water, with performance data provided for different flow rates and pressures.
Technical Specifications
  • Temperature and Heating: Maximum temperature for water is 90°C and for oil is 150°C. Heating capacity is 9 kW for water and 3 kW for oil.
  • Cooling Capacity: Refer to the provided diagram for detailed cooling capacity information.
  • Filling Volume: Minimum 5 liters, maximum 7 liters for heat-transfer fluid.
  • Pump Type: Type E with performance data ranging from 16 l/min at 1.5 bar to 38 l/min at 8 bar.
  • Control System: MP-888 with temperature measurement using a FeKo type J sensor.
  • Connections: Various thread specifications for heat-transfer fluid and cooling water connections.
  • Environmental Conditions: Operating temperature range is 5-40°C with relative humidity between 40-80% RH.
  • Power Supply: Options include 380-480 V or 200-240 V, with specific conductor cross-section requirements.
  • Ingress Protection: Rated at IP44 with CE marking.
Performance and Features
The equipment includes features such as mould emptying, leak stopper function, and flow measurement capabilities. The document also highlights the noise level, which is maintained below 70 dB (A).
See more

Catalog excerpts

CLASSIC Duo TT-181-1

Pump characteristic CLASSIC, Oil CLASSIC, Water MATIC, Oil, 150°C MATIC, Water MATIC, Oil, 45°C ▪ Leak stopper function ▪ Mould emptying ▪ Leak stopper function ▪ Flow measurement Flow rate (l/min) Cooling capacity 10 l/min 20 l/min 40 l/min Oil, 40 l/min Oil, 10 l/min Temperature difference between flow and cooling water (°C) Performance data min. at 16 l/min @ 1.5 bar; max. at 38 l/min @ 8 bar cooling water Fluidic diagram CLASSIC Duo TT-181 1 2-2 way valve (normally closed), 2 pump motor, 3 pump with reversible pumping direction, 4 Cooling coil, 5 Filter, 6 Flow sensor (TT-188), 7 Ball valve, 8 Heating element, 9 Level sensor, 10 Temperature sensor, 11 Thermostat, 12 Pressure sensor, 13 Pump bypass Tool-Temp AG | Switzerland | tool-temp.ch

 Open the catalog to page 1
CLASSIC Duo TT-181-2

Maximum temperature Heating capacity Cooling capacity Filling volume (heat-transfer fluid) Pressure and flow rate Motor rated power Control system Temperature measurement Pump-pressure measurement Flow measurement (heat-transfer fluid) Connections Heat-transfer fluid (feed and return) Cooling water inlet Cooling water outlet Empty weight Temperature range Relative humidity Continuous noise level Power supply Connected load Conductor cross-section of connection cable Ingress protection code Marking Minimum 5 liters, maximum 7 liters Temperature sensor FeKo type J Manometer Paddle-wheel sensor...