TonHe Technology New Energy Vehicle Business Group 40kW V2G «TH40GT10030C8E-WTAnti-islanding protection effectively enhance operational safety of the module Ultra-low power consumption active power <10W reactive power <12Var Three-phase five-wire system add neutral wire to improve power quality significantly reduce module heat loss and improve efficiency Rectification mode constant power output range Inverter mode constant power input range 300Vdc-1000Vdc • Rectification Mode Rated output power: Rated input voltage: Rated output voltage: Input voltage operating range: Output voltage range: Output constant power range: Voltage regulation accuracy: Current regulation accuracy: • Inversion Mode Input voltage constant power range: Rated input voltage: Rated output voltage: Anti-islanding protection: • Product Other Parameters Cooling method: Communication bus protocol: Wiring method: Address setting: • Operating Environment Operating temperature: Relative humidity: constant 40kW from 300Vdc to lOOOVdc <±0.5% three-phase five-wire system digital display and button operation -40°C~75°C (output derating above 50°C) 5%-95% RH, non-condensing
Open the catalog to page 127 Pages
14 Pages