1. Catalogs
  2. Tongdy Control Technology
  3. F2000TSM-TH temperature transmitter for smart room | Tongdy®

F2000TSM-TH temperature transmitter for smart room | Tongdy®

F2000TSM-TH temperature transmitter for smart room | Tongdy®

F2000TSM-TH temperature transmitter for smart room | Tongdy®

Product catalog summary
Features
  • Designed for measuring relative humidity and temperature.
  • Provides up to two outputs (0~10VDC/4~20mA/0~5VDC) for humidity and temperature measurements.
  • Humidity output is automatically corrected across all operating conditions.
  • Allows arbitrary point setup for temperature and humidity measurement modification.
  • Optional Modbus RS485 communication.
  • Wall mounting with a smart structure.
Specifications
  • Temperature: Digital Temp.&RH combined sensor, measuring range 0℃~50℃ (32℉~122℉), accuracy ±0.5℃ (20~40℃), stability ±0.04℃ per year.
  • Relative Humidity: Digital Temp.&RH combined sensor, measuring range 0-100%RH, accuracy ±4.5%RH (20%-80%RH), stability <0.5%RH per year.
  • Storage Environment: 10~50℃ (32℉~122℉) / 20~60%RH.
  • Connection: Screw terminals.
  • Set Measurement Zone: Configurable via Modbus.
  • Housing/IP Class: PC/ABS fireproof material/IP 40.
  • Output: 0~10VDC (default) or 4~20mA (selectable by jumpers), 0~5VDC (selected at order).
  • Power Supply: 24VAC/VDC±10%, power cost ≤2W, resistance permitted ≤500Ω.
  • Net Weight: 180g.
  • Dimensions: (W)100mm×(H)80mm×(D)28mm.
  • Installation Standard: 65mm×65mm or 2”×4” wire box.
  • Approval: CE-Approval.
Models Information
  • F2000TSM-TH-M100: 1X analog linear output for temperature measurement.
  • F2000TSM-TH-M100-RH: 1X analog linear output for RH measurement.
  • F2000TSM-TH-M101: 1X analog linear output for temperature measurement with Modbus RS485 interface.
  • F2000TSM-TH-M101-RH: 1X analog linear output for RH measurement with Modbus RS485 interface.
  • F2000TSM-TH-M200: 2X analog linear outputs for temperature and RH measurements.
  • F2000TSM-TH–M201: 2X analog linear outputs for temperature and RH measurements with Modbus RS485 interface.
  • F2000TSM-TH–M001: Modbus RS485 interface for temperature & RH measurements.

Postfix 1 indicates the type of output signal: -V (0~10VDC, default), -A (4~20mA), -V5 (0~5VDC, not changeable). Postfix 2 indicates temperature scaling: T05 (0℃~50℃, default), T06 (0℃~60℃), T26 (-20℃~60℃).

Example: F2000TSM-TH-M100-V5-T06 indicates a transmitter with 1X 0~5VDC output and temperature scaling of 0~60℃.

Wiring Diagrams

Diagrams are provided for different models indicating connections for power supply, outputs, and RS-485 interface.

Mounting

Dimensions and mounting instructions are provided for proper installation.

See more

Catalog excerpts

F2000TSM-TH temperature transmitter for smart room | Tongdy®-1

F2000TSM-TH Temperature & Humidity Transmitter CE-Approval Features Designed for transmit relative humidity measurement and temperature measurement. Provide up to 2x0~10VDC/4~20mA/0~5VDC outputs for humidity and temperature measurements Humidity output is automatically corrected over the full range of operating conditions Arbitrary point setup of temperature and humidity measurement modification Modbus RS485 communication is optional Wall mounting with the smart structure Specifications Temperature Sensing element: Relative Humidity Digital Temp.&RH combined sensor Digital Temp.&RH combined sensor Measuring range Storage environment Screw terminals Housing/IP Class PC/ABS fireproof material/IP 40 0~10VDC(default) or 4~20mA (selectable by jumpers) Output 0~5VDC (selected at place the order) Power supply Power cost Resistance permitted Installation standard

 Open the catalog to page 1
F2000TSM-TH temperature transmitter for smart room | Tongdy®-2

Models Information Model 1Xanalog linear output for temperature measurement. 1Xanalog linear output for RH measurement. 1Xanalog linear output for temperature measurement. 2Xanalog linear outputs for temperature and RH measurements. Modbus RS485 interface. Modbus RS485 interface for temperature & RH measurements. type of output signal -V Modbus RS485 interface can read temperature and RH measurements.. 2Xanalog linear outputs for temperature and RH measurements 1Xanalog linear output for RH measurement. (without the postfix indicates the default) For example: F2000TSM-TH-M100-V5-T06 indicates...

 Open the catalog to page 2
F2000TSM-TH temperature transmitter for smart room | Tongdy®-3

Add: Building #8, Courtyard #9, Dijin Road, Haidian District, Beijing, 100095, China

 Open the catalog to page 3

All Tongdy Control Technology catalogs and technical brochures

  1. MSD

    6  Pages

  2. TSP-16

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.