F08-LVB series of BACnet VAV thermostat | Tongdy®
3Pages

{{requestButtons}}

Catalog excerpts

F08-LVB series of BACnet VAV thermostat | Tongdy® - 1

BacNet Commercial Thermostat F08-LVB Series Room Thermostat for VAV Terminals Typical used in buildings for VAV systems All models feature user-friendly setting buttons Designed for BACnet MS/TP networks with 1x0~ 10 VDC output to cooling/heating air damper or Smart and enough advanced setup makes the thermostat being used in all VAV systems Up to two-stage electric aux. heater control makes 2x0~10VDC outputs to cooling and heating air dampers, also with one or two relay outputs to one temperature controlling more accurate and energy-saving. Large set point adjustment, the mini. and max. limit or two stages electric auxiliary heater A PIC statement is supplied to be easily of temperature preset by end users mapped back to a graphical user interface. Celsius or Fahrenheit degree selectable Self configuring / adjustable baud-rate senses the Cooling/heating mode auto changeover or manual communication conditions of the current MS/TP switch selectable Two parts structure and quick wire terminal blocks network and match them. BACnet PIC statement provided to further facilitate make mounting easily. Infrared Remote Control (optional) Blue backlight (optional) LCD can display working status such as room temperature, set point, analog output, etc. Makes reading and operating easy and accurate. Buttons and LCD Display measured and setting temperature temperature cooling heating cooling/heating switch turn on/off down Power supply

Open the catalog to page 1
F08-LVB series of BACnet VAV thermostat | Tongdy® - 2

Electrical rating Temperature control range Analog output Current Relay output 1 or 2 outputs with 2 Amp load Protection class Environment condition Operating temperature: 0 – 50 ℃ Operating humidity: 5 ~99% RH Storage temperature: -10 – 60 0C Storage humidity: < 95%RH BACnet interface BACnet MS/TP with adjustable baud-rate PC/ABS plastic material with IP30 protection class Mounting standard Mounting on the wall, or 2“×4“/ 65mm×65mm pipe box Models Type 1X 0~10V output for an actuator, 1X on/off contact output to a heater. Cooling/heating switch. 1X 0~10V output for an actuator, 2X on/off...

Open the catalog to page 2
F08-LVB series of BACnet VAV thermostat | Tongdy® - 3

Shipping Information Indiv. Ctn. Dim Mounting and Wiring Diagrams MS/TP MS/TP - MS/TP+ MS/TP Heat Relay Heat Relay Heat Relay Heat Relay Heat Relay Heat Relay

Open the catalog to page 3