CO2 DETECTOR/INDICATOR F2000IAQ-CO2-3100/3101/5100/5101 CE Approval F2000IAQ-CO2 detector/Indicator is used to monitor and alarm CO2 level and room temperature. Relative humidity detection and display can be as an option. Other options can be provided to users: RS485 communication interface with independent address; one dry contact output to control a ventilation device. Especial design for schools, kindergartens, office buildings, conference rooms, rest rooms as well as other public places Built-in NDIR CO2 module, 15 years long life. ABC Logic self calibration algorithm for CO2 sensor. Real-time detect and display room CO2 and temperature 3 LED indicator lights following three different CO2 ranges to indicate ambiance ventilation situation: Optimal Ventilation; Poor Ventilation and Insufficient Ventilation. Optional humidity detection and display Real-time detecting and display CO2 level during 0ppm to 20,000ppm CO2 range; Also detecting room The three measured CO2 ranges for 3-LED indicator lights selectable by end users LED’s brightness adjustment Optional real-time humidity from 5%RH to 95%RH Optional 1X dry contact output or one 0~10VDC output to NDIR CO2 sensor technology of infrared self control a ventilation device diffusion, 15 years lifetime Easy preset CO2 level for buzzer alert (optional) Self Calibration Algorithm makes it in using without Optional RS485 interface to connect to a PC or calibration amending another system (optional) Sensing element Non-Depressive Infrared Detector (NDIR) Temperature sensor Temperature correction Self compensation <2% of FS over life of sensor (15 yr typical) 2 hours (first time) 2 minutes (operation) CO2 setting & Display resolution Temperature measuring range Temperature setting range Option: 1X dry contact output Rated currency for contact point: 2A 220VAC/30VDC, resistance load

Open the catalog to page 1
CO2 indicator/controller: F2000IAQ-CO2-31/51 | Tongdy® - 2

Option: RS485 communication interface 9600/14400/19200(default)/28800/38400bps rates selectable program,15KV protection for static, independent address setting Operation condition Power supply Connections Interface Locate in interface of connection Installment standard Wiring standard Approval Standard DIP switches inside and external push-buttons Buttons and LCD room temperature ventilation device on Insufficient ventilation poor ventilation optimal ventilation turn on/off switch setting decrease increase Shipping Information India. Ctn. Dim Master Ctn. Qty Wiring Diagram

Open the catalog to page 2
CO2 indicator/controller: F2000IAQ-CO2-31/51 | Tongdy® - 3

Model Guide Gas Type CO2 Carbon Dioxide Standard model (CO2 &temperature detection) CO2 &temperature detection with RS-485 network communication Analog output Humidity option Relative humidity detection Power supply Note: X2 + X3 ≤1 Example: F2000IAQ-CO2-3100 indicates that it is a CO2 indicator with temperature detection.

Open the catalog to page 3

All Tongdy Control Technology catalogs and technical brochures

  1. MSD

    6 Pages

  2. TSP-16

    4 Pages