Overview: The document describes the TKG-CO2-1010D-PP, a plug and play carbon dioxide controller designed for use in greenhouses and similar environments. It features a non-dispersive infrared (NDIR) CO2 sensor with self-calibration and a lifespan of over 10 years. The device is CE-approved and supports a wide power supply range of 100VAC to 240VAC.
Features:
  • Easy plug and play setup with European or American power plugs.
  • Includes a photosensitive sensor for automatic day/night mode switching.
  • Replaceable filter and extendable probe length.
  • Optional external sensor with a 2-meter cable.
Specifications:
  • CO2 measurement range: 0-2,000ppm (default) and 0-5,000ppm (preset).
  • Accuracy: ±60ppm + 3% of reading at 22℃.
  • Response time: Less than 5 minutes for 90% step change.
  • Power consumption: 1.8W max, 1.0W average.
  • Operating conditions: 0℃ to 60℃, 0-99% RH non-condensing.
  • IP class: IP30.
Applications:
  • Controlling CO2 levels in greenhouses and similar applications.
  • Use in CO2 laboratories and ventilation systems.
  • End users can preset the working mode for CO2 generators or ventilators.
Dimensions and Mounting:
  • Wall mounting with plug and play capability.
  • Probe length: 69.00mm, diameter: Ø26.00mm.
  • Power cable length: 1100mm, device cable length: 700mm.
Shipping Information:
  • Individual carton dimensions: 255mm x 130mm x 115mm.
  • Master carton quantity: 15 units, dimensions: 49cm x 36cm x 42cm, net weight: 20kg.
See more

Catalog excerpts

CO2 controller for greenhouse: TKG-CO2-1010D-PP | Tongdy®-1

TKG-CO2-1010D-PP Plug and Play Carbon Dioxide Controller for Greenhouse CE Approval Features Design for control the CO2 concentration in greenhouses or mushrooms NDIR infrared CO2 sensor inside with Self-Calibration and up to more than 10 years lifetime. Plug & play type, very easy to connect the power and a fan or CO2 generator. 100VAC~240VAC range power supply with European or American power plug and power connector. A max. 8A relay dry contact output Inside a photosensitive sensor for auto changeover day/night work mode Replaceable filter in the probe and extendable probe length. Design the convenient and easier buttons for operation. Optional split external sensor with 2 meter cables CE-Approval. Connect the controlled device Connect the 100V~240V power supply European/American power plug& connector optional

 Open the catalog to page 1
CO2 controller for greenhouse: TKG-CO2-1010D-PP | Tongdy®-2

One application of the split controller and sensor Non-Dispersive Infrared Detector (NDIR) Measurement Range <2% of full scale over the life of the sensor Self-calibration system Response Time <5 minutes for 90% step change at low duct speed Pressure Dependence 2 hours (first time) 2 minutes (operation) 2 meter cable connection between the senor and the controller Power supply Dry contact output (optional) 1xdry contact output Max. switch current: 8A (load resistance) SPDT relay Plug& play type 100VAC~240VAC power supply with European or American power plug and power connector to the CO2 generator...

 Open the catalog to page 2
CO2 controller for greenhouse: TKG-CO2-1010D-PP | Tongdy®-3

Typical Application: TKG-CO2-1010D-PP Controller is used to control CO2 level in greenhouse and other similar applications, providing a max 8A relay on/off output to control a CO2 generator or a fan. For ventilation system in greenhouse. The CO2 generator(default) or ventilator working mode can be preset by the end users Demensions & Mounting Wall mounting with plug&play probe Length Probe Diameter Installation Holes Power cable Cable to device Power plug/socket 1100.00mm 700.00mm European American Power input side 100-240VAC/5A Diameter: 3 * 1.5 mm 2 And wire length: 1100 mm Control equipment...