Axiom Plus v. 2.5 with Analog Input Brochure
2Pages

{{requestButtons}}

Catalog excerpts

Axiom Plus v. 2.5 with Analog Input Brochure - 1

As part of our ongoing commitment to continuation engineering, Tol-O-Matic is pleased to announce the release of version 2.5x of the AxiomPlus. We have incorporated a variety of user-requested features, intended to enhance connectivity, expand the possible applications and increase usability of the AxiomPlus. These features will allow users to connect to a wide range of human interface and analog devices, connect several controllers together and interact in realtime with both the sequential program and the PLC. For a more in-depth understanding of all these features and their use, you can visit www.tolomatic.com and view or download the most recent AxiomPlus Software User’s Manual, or call our technical sales group at 1-800-328-2174. New Features Including Analog Input • Dual use analog input (use as analog or opto-isolated input) • Debug mode added to sequential program Run program in single steps, multiple steps or to a specified line number "Watch window" for monitoring and changing values of registers and flags • Registers have been expanded to include counter, timer and analog values in addition to position, velocity and torque limit • PLC flags and I/O can be read and written via ModBus or serial port ASCII commands • Sequential programming instructions added: Absolute position feedback based on analog input Analog input position and velocity (force control) moves Save analog input to register Branch on analog input compare Modify count register value • PLC instructions added: "Range window" to process variable compare instruction

Open the catalog to page 1
Axiom Plus v. 2.5 with Analog Input Brochure - 2

This new release makes Additional ModBus, • ModBus RTU and ASCII connectivity • More registers added along with the ability to use them in more • Project Save and Load, Upload and • Automatic prompting for serial port • Sequential programming instructions added: Assign value to a register. Save Position to Register Maximum Torque Limit Parameter Software Travel Limits Branch on Position Compare In-Position Band value can now be entered as user units Register Compare Input Logic Indexer Status Flag for Torque Peak Limit Select Register Clare l-H-.li Wl-Jll AtttS* REOSTEfcl :rLm r.nuyp'JFr...

Open the catalog to page 2

All Tolomatic catalogs and technical brochures

  1. ERD Catalog

    32 Pages

  2. AppTip_SRG

    2 Pages

Archived catalogs