VG 12500TE

VG 12500TE

Product catalog summary
Product Overview: The document provides technical specifications for a portable gasoline generator model VG 12500TE by NSM Saccardo. It is designed for continuous and standby power supply.
Specifications:
  • Model: VG 12500TE
  • Engine Type: 4-Stroke, Air Cooled
  • Number of Cylinders/Type: 2 / V Twin
  • Displacement: 3854 cc
  • Power Output: 11.3 Hp
  • Bore/Stroke: 78x73 mm
  • Oil Capacity: 1.7 liters
  • Fuel Type: Gasoline
  • Fuel Tank Capacity: 20 liters
  • Voltage: 380V (50Hz)
  • Alternator: Not specified
  • Start System: Electric Start
  • Size (L x W x H): 78x73x77 cm
  • Weight: 145 kg
Power Ratings:
  • Prime Power: 12.5 kVA
  • Standby Power: Not specified
Operational Guidelines:
  • The generator can deliver continuous power while supplying a constant electrical load, with an average load of 100%.
  • Overloading is not permissible during continuous operation.
  • For standby power, the generator can operate under variable electrical load conditions for up to 200 hours per year at an average of 70% load.
  • During prime power operation, the generator can be overloaded by 10% for 1 hour every 12 hours, with an average load of 70%.
Contact Information: For more details, visit www.tmgpower.com.tr or contact via phone at +90 212 641 94 21 or email at [email protected]. The company is located at Mermerciler Sanayi Sitesi 3. Cadde No: 7 /B Beylikduzu, Istanbul, Turkey.
See more

Catalog excerpts

VG 12500TE-1

Genset Standby PORTABLE GASOLINE GENSET Start System Electric Start Continuous Power The maximum power which a generating set is capable of delivering continuouslywhilst supplying a constant electrical load. Average load can be 100%. The generator must not be overloaded. Fuel Type Fuel Tank Capacity Engine Model Standby Power The maxpower available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utilitypower outage or under test conditions for up to 200 hrs of operation per year under average of 70%load.Overloading isn’t permissible. Number of Cylinder / Type Engine Type Prime Power The maximum power which a generating set is capable of delivering continuouslywhilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs. Size Weight Mermerciler Sanayi Sitesi 3. Cadde No: 7 /B Beylikduzu / ISTANBUL / TURKEY +90 212 641 94 21 | [email protected]

 Open the catalog to page 1

All TMG POWER catalogs and technical brochures

  1. TMG POWER

    28  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.